1 // SPDX-License-Identifier: GPL-2.0-only
3 * step_wise.c - A step-by-step Thermal throttling governor
5 * Copyright (C) 2012 Intel Corp
6 * Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
8 * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
10 * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
13 #include <linux/thermal.h>
14 #include <trace/events/thermal.h>
16 #include "thermal_core.h"
19 * If the temperature is higher than a trip point,
20 * a. if the trend is THERMAL_TREND_RAISING, use higher cooling
21 * state for this trip point
22 * b. if the trend is THERMAL_TREND_DROPPING, do nothing
23 * c. if the trend is THERMAL_TREND_RAISE_FULL, use upper limit
25 * d. if the trend is THERMAL_TREND_DROP_FULL, use lower limit
27 * If the temperature is lower than a trip point,
28 * a. if the trend is THERMAL_TREND_RAISING, do nothing
29 * b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
30 * state for this trip point, if the cooling state already
31 * equals lower limit, deactivate the thermal instance
32 * c. if the trend is THERMAL_TREND_RAISE_FULL, do nothing
33 * d. if the trend is THERMAL_TREND_DROP_FULL, use lower limit,
34 * if the cooling state already equals lower limit,
35 * deactivate the thermal instance
37 static unsigned long get_target_state(struct thermal_instance
*instance
,
38 enum thermal_trend trend
, bool throttle
)
40 struct thermal_cooling_device
*cdev
= instance
->cdev
;
41 unsigned long cur_state
;
42 unsigned long next_target
;
45 * We keep this instance the way it is by default.
46 * Otherwise, we use the current state of the
47 * cdev in use to determine the next_target.
49 cdev
->ops
->get_cur_state(cdev
, &cur_state
);
50 next_target
= instance
->target
;
51 dev_dbg(&cdev
->device
, "cur_state=%ld\n", cur_state
);
53 if (!instance
->initialized
) {
55 next_target
= (cur_state
+ 1) >= instance
->upper
?
57 ((cur_state
+ 1) < instance
->lower
?
58 instance
->lower
: (cur_state
+ 1));
60 next_target
= THERMAL_NO_TARGET
;
67 case THERMAL_TREND_RAISING
:
69 next_target
= cur_state
< instance
->upper
?
70 (cur_state
+ 1) : instance
->upper
;
71 if (next_target
< instance
->lower
)
72 next_target
= instance
->lower
;
75 case THERMAL_TREND_RAISE_FULL
:
77 next_target
= instance
->upper
;
79 case THERMAL_TREND_DROPPING
:
80 if (cur_state
<= instance
->lower
) {
82 next_target
= THERMAL_NO_TARGET
;
85 next_target
= cur_state
- 1;
86 if (next_target
> instance
->upper
)
87 next_target
= instance
->upper
;
91 case THERMAL_TREND_DROP_FULL
:
92 if (cur_state
== instance
->lower
) {
94 next_target
= THERMAL_NO_TARGET
;
96 next_target
= instance
->lower
;
105 static void update_passive_instance(struct thermal_zone_device
*tz
,
106 enum thermal_trip_type type
, int value
)
109 * If value is +1, activate a passive instance.
110 * If value is -1, deactivate a passive instance.
112 if (type
== THERMAL_TRIP_PASSIVE
|| type
== THERMAL_TRIPS_NONE
)
113 tz
->passive
+= value
;
116 static void thermal_zone_trip_update(struct thermal_zone_device
*tz
, int trip
)
119 enum thermal_trip_type trip_type
;
120 enum thermal_trend trend
;
121 struct thermal_instance
*instance
;
122 bool throttle
= false;
125 if (trip
== THERMAL_TRIPS_NONE
) {
126 trip_temp
= tz
->forced_passive
;
127 trip_type
= THERMAL_TRIPS_NONE
;
129 tz
->ops
->get_trip_temp(tz
, trip
, &trip_temp
);
130 tz
->ops
->get_trip_type(tz
, trip
, &trip_type
);
133 trend
= get_tz_trend(tz
, trip
);
135 if (tz
->temperature
>= trip_temp
) {
137 trace_thermal_zone_trip(tz
, trip
, trip_type
);
140 dev_dbg(&tz
->device
, "Trip%d[type=%d,temp=%d]:trend=%d,throttle=%d\n",
141 trip
, trip_type
, trip_temp
, trend
, throttle
);
143 mutex_lock(&tz
->lock
);
145 list_for_each_entry(instance
, &tz
->thermal_instances
, tz_node
) {
146 if (instance
->trip
!= trip
)
149 old_target
= instance
->target
;
150 instance
->target
= get_target_state(instance
, trend
, throttle
);
151 dev_dbg(&instance
->cdev
->device
, "old_target=%d, target=%d\n",
152 old_target
, (int)instance
->target
);
154 if (instance
->initialized
&& old_target
== instance
->target
)
157 /* Activate a passive thermal instance */
158 if (old_target
== THERMAL_NO_TARGET
&&
159 instance
->target
!= THERMAL_NO_TARGET
)
160 update_passive_instance(tz
, trip_type
, 1);
161 /* Deactivate a passive thermal instance */
162 else if (old_target
!= THERMAL_NO_TARGET
&&
163 instance
->target
== THERMAL_NO_TARGET
)
164 update_passive_instance(tz
, trip_type
, -1);
166 instance
->initialized
= true;
167 mutex_lock(&instance
->cdev
->lock
);
168 instance
->cdev
->updated
= false; /* cdev needs update */
169 mutex_unlock(&instance
->cdev
->lock
);
172 mutex_unlock(&tz
->lock
);
176 * step_wise_throttle - throttles devices associated with the given zone
177 * @tz: thermal_zone_device
178 * @trip: trip point index
180 * Throttling Logic: This uses the trend of the thermal zone to throttle.
181 * If the thermal zone is 'heating up' this throttles all the cooling
182 * devices associated with the zone and its particular trip point, by one
183 * step. If the zone is 'cooling down' it brings back the performance of
184 * the devices by one step.
186 static int step_wise_throttle(struct thermal_zone_device
*tz
, int trip
)
188 struct thermal_instance
*instance
;
190 thermal_zone_trip_update(tz
, trip
);
192 if (tz
->forced_passive
)
193 thermal_zone_trip_update(tz
, THERMAL_TRIPS_NONE
);
195 mutex_lock(&tz
->lock
);
197 list_for_each_entry(instance
, &tz
->thermal_instances
, tz_node
)
198 thermal_cdev_update(instance
->cdev
);
200 mutex_unlock(&tz
->lock
);
205 static struct thermal_governor thermal_gov_step_wise
= {
207 .throttle
= step_wise_throttle
,
209 THERMAL_GOVERNOR_DECLARE(thermal_gov_step_wise
);