1 Kernel driver ltc2990
2 =====================
5 Supported chips:
7   * Linear Technology LTC2990
9     Prefix: 'ltc2990'
11     Addresses scanned: -
13     Datasheet: http://www.linear.com/product/ltc2990
17 Author:
19         - Mike Looijmans <mike.looijmans@topic.nl>
20         - Tom Levens <tom.levens@cern.ch>
23 Description
24 -----------
26 LTC2990 is a Quad I2C Voltage, Current and Temperature Monitor.
27 The chip's inputs can measure 4 voltages, or two inputs together (1+2 and 3+4)
28 can be combined to measure a differential voltage, which is typically used to
29 measure current through a series resistor, or a temperature with an external
30 diode.
33 Usage Notes
34 -----------
36 This driver does not probe for PMBus devices. You will have to instantiate
37 devices explicitly.
40 Sysfs attributes
41 ----------------
43 ============= ==================================================
44 in0_input     Voltage at Vcc pin in millivolt (range 2.5V to 5V)
45 temp1_input   Internal chip temperature in millidegrees Celsius
46 ============= ==================================================
48 A subset of the following attributes are visible, depending on the measurement
49 mode of the chip.
51 ============= ==========================================================
52 in[1-4]_input Voltage at V[1-4] pin in millivolt
53 temp2_input   External temperature sensor TR1 in millidegrees Celsius
54 temp3_input   External temperature sensor TR2 in millidegrees Celsius
55 curr1_input   Current in mA across V1-V2 assuming a 1mOhm sense resistor
56 curr2_input   Current in mA across V3-V4 assuming a 1mOhm sense resistor
57 ============= ==========================================================
59 The "curr*_input" measurements actually report the voltage drop across the
60 input pins in microvolts. This is equivalent to the current through a 1mOhm
61 sense resistor. Divide the reported value by the actual sense resistor value
62 in mOhm to get the actual value.