Btrfs: fix negative subv_writers counter and data space leak after buffered write
[linux/fpc-iii.git] / Documentation / hwmon / nsa320.rst
blob4fe75fd2f937d5262eea6378de2a38605ba41bb3
1 Kernel driver nsa320_hwmon
2 ==========================
4 Supported chips:
6   * Holtek HT46R065 microcontroller with onboard firmware that configures
8         it to act as a hardware monitor.
10     Prefix: 'nsa320'
12     Addresses scanned: none
14     Datasheet: Not available, driver was reverse engineered based upon the
16         Zyxel kernel source
20 Author:
22   Adam Baker <linux@baker-net.org.uk>
24 Description
25 -----------
27 This chip is known to be used in the Zyxel NSA320 and NSA325 NAS Units and
28 also in some variants of the NSA310 but the driver has only been tested
29 on the NSA320. In all of these devices it is connected to the same 3 GPIO
30 lines which are used to provide chip select, clock and data lines. The
31 interface behaves similarly to SPI but at much lower speeds than are normally
32 used for SPI.
34 Following each chip select pulse the chip will generate a single 32 bit word
35 that contains 0x55 as a marker to indicate that data is being read correctly,
36 followed by an 8 bit fan speed in 100s of RPM and a 16 bit temperature in
37 tenths of a degree.
40 sysfs-Interface
41 ---------------
43 ============= =================
44 temp1_input   temperature input
45 fan1_input    fan speed
46 ============= =================
48 Notes
49 -----
51 The access timings used in the driver are the same as used in the Zyxel
52 provided kernel. Testing has shown that if the delay between chip select and
53 the first clock pulse is reduced from 100 ms to just under 10ms then the chip
54 will not produce any output. If the duration of either phase of the clock
55 is reduced from 100 us to less than 15 us then data pulses are likely to be
56 read twice corrupting the output. The above analysis is based upon a sample
57 of one unit but suggests that the Zyxel provided delay values include a
58 reasonable tolerance.
60 The driver incorporates a limit that it will not check for updated values
61 faster than once a second. This is because the hardware takes a relatively long
62 time to read the data from the device and when it does it reads both temp and
63 fan speed. As the most likely case for two accesses in quick succession is
64 to read both of these values avoiding a second read delay is desirable.