1 Kernel driver sht15
2 ===================
4 Authors:
5   * Wouter Horre
6   * Jonathan Cameron
7   * Vivien Didelot <vivien.didelot@savoirfairelinux.com>
8   * Jerome Oufella <jerome.oufella@savoirfairelinux.com>
10 Supported chips:
11   * Sensirion SHT10
12     Prefix: 'sht10'
14   * Sensirion SHT11
15     Prefix: 'sht11'
17   * Sensirion SHT15
18     Prefix: 'sht15'
20   * Sensirion SHT71
21     Prefix: 'sht71'
23   * Sensirion SHT75
24     Prefix: 'sht75'
26 Datasheet: Publicly available at the Sensirion website
27 http://www.sensirion.ch/en/pdf/product_information/Datasheet-humidity-sensor-SHT1x.pdf
29 Description
30 -----------
32 The SHT10, SHT11, SHT15, SHT71, and SHT75 are humidity and temperature
33 sensors.
35 The devices communicate using two GPIO lines.
37 Supported resolutions for the measurements are 14 bits for temperature and 12
38 bits for humidity, or 12 bits for temperature and 8 bits for humidity.
40 The humidity calibration coefficients are programmed into an OTP memory on the
41 chip. These coefficients are used to internally calibrate the signals from the
42 sensors. Disabling the reload of those coefficients allows saving 10ms for each
43 measurement and decrease power consumption, while loosing on precision.
45 Some options may be set directly in the sht15_platform_data structure
46 or via sysfs attributes.
48 Notes:
49   * The regulator supply name is set to "vcc".
50   * If a CRC validation fails, a soft reset command is sent, which resets
51     status register to its hardware default value, but the driver will try to
52     restore the previous device configuration.
54 Platform data
55 -------------
57 * checksum:
58   set it to true to enable CRC validation of the readings (default to false).
59 * no_otp_reload:
60   flag to indicate not to reload from OTP (default to false).
61 * low_resolution:
62   flag to indicate the temp/humidity resolution to use (default to false).
64 Sysfs interface
65 ---------------
67 * temp1_input:     temperature input
68 * humidity1_input: humidity input
69 * heater_enable:   write 1 in this attribute to enable the on-chip heater,
70                    0 to disable it. Be careful not to enable the heater
71                    for too long.
72 * temp1_fault:     if 1, this means that the voltage is low (below 2.47V) and
73                    measurement may be invalid.
74 * humidity1_fault: same as temp1_fault.