3 These properties cover the base properties Micrel PHYs.
7 - micrel,led-mode : LED mode value to set for PHYs with configurable LEDs.
9 Configure the LED mode with single value. The list of PHYs and the
10 bits that are currently supported:
12 KSZ8001: register 0x1e, bits 15..14
13 KSZ8041: register 0x1e, bits 15..14
14 KSZ8021: register 0x1f, bits 5..4
15 KSZ8031: register 0x1f, bits 5..4
16 KSZ8051: register 0x1f, bits 5..4
17 KSZ8081: register 0x1f, bits 5..4
18 KSZ8091: register 0x1f, bits 5..4
20 See the respective PHY datasheet for the mode values.
22 - micrel,rmii-reference-clock-select-25-mhz: RMII Reference Clock Select
23 bit selects 25 MHz mode
25 Setting the RMII Reference Clock Select bit enables 25 MHz rather
26 than 50 MHz clock mode.
28 Note that this option in only needed for certain PHY revisions with a
29 non-standard, inverted function of this configuration bit.
30 Specifically, a clock reference ("rmii-ref" below) is always needed to
31 actually select a mode.
33 - clocks, clock-names: contains clocks according to the common clock bindings.
36 - KSZ8021, KSZ8031, KSZ8081, KSZ8091: "rmii-ref": The RMII reference
37 input clock. Used to determine the XI input clock.