2 # Network device configuration
8 bool "Network device support"
10 You can say N here if you don't intend to connect your Linux box to
11 any other computer at all.
13 You'll have to say Y if your computer contains a network card that
14 you want to use under Linux. If you are going to run SLIP or PPP over
15 telephone line or null modem cable you need say Y here. Connecting
16 two machines with parallel ports using PLIP needs this, as well as
17 AX.25/KISS for sending Internet traffic over amateur radio links.
19 See also "The Linux Network Administrator's Guide" by Olaf Kirch and
20 Terry Dawson. Available at <http://www.tldp.org/guides.html>.
24 # All the following symbols are dependent on NETDEVICES - do not repeat
25 # that for each of the symbols.
33 bool "Network core driver support"
35 You can say N here if you do not intend to use any of the
36 networking core drivers (i.e. VLAN, bridging, bonding, etc.)
41 tristate "Bonding driver support"
43 depends on IPV6 || IPV6=n
45 Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
46 Channels together. This is called 'Etherchannel' by Cisco,
47 'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.
49 The driver supports multiple bonding modes to allow for both high
50 performance and high availability operation.
52 Refer to <file:Documentation/networking/bonding.txt> for more
55 To compile this driver as a module, choose M here: the module
56 will be called bonding.
59 tristate "Dummy net driver support"
61 This is essentially a bit-bucket device (i.e. traffic you send to
62 this device is consigned into oblivion) with a configurable IP
63 address. It is most commonly used in order to make your currently
64 inactive SLIP address seem like a real address for local programs.
65 If you use SLIP or PPP, you might want to say Y here. It won't
66 enlarge your kernel. What a deal. Read about it in the Network
67 Administrator's Guide, available from
68 <http://www.tldp.org/docs.html#guide>.
70 To compile this driver as a module, choose M here: the module
74 tristate "EQL (serial line load balancing) support"
76 If you have two serial connections to some other computer (this
77 usually requires two modems and two telephone lines) and you use
78 SLIP (the protocol for sending Internet traffic over telephone
79 lines) or PPP (a better SLIP) on them, you can make them behave like
80 one double speed connection using this driver. Naturally, this has
81 to be supported at the other end as well, either with a similar EQL
82 Linux driver or with a Livingston Portmaster 2e.
84 Say Y if you want this and read
85 <file:Documentation/networking/eql.txt>. You may also want to read
86 section 6.2 of the NET-3-HOWTO, available from
87 <http://www.tldp.org/docs.html#howto>.
89 To compile this driver as a module, choose M here: the module
90 will be called eql. If unsure, say N.
93 bool "Fibre Channel driver support"
94 depends on SCSI && PCI
96 Fibre Channel is a high speed serial protocol mainly used to connect
97 large storage devices to the computer; it is compatible with and
98 intended to replace SCSI.
100 If you intend to use Fibre Channel, you need to have a Fibre channel
101 adaptor card in your computer; say Y here and to the driver for your
102 adaptor below. You also should have said Y to "SCSI support" and
103 "SCSI generic support".
106 tristate "Intermediate Functional Block support"
107 depends on NET_CLS_ACT
109 This is an intermediate driver that allows sharing of
111 To compile this driver as a module, choose M here: the module
112 will be called ifb. If you want to use more than one ifb
113 device at a time, you need to compile this driver as a module.
114 Instead of 'ifb', the devices will then be called 'ifb0',
116 Look at the iproute2 documentation directory for usage etc
118 source "drivers/net/team/Kconfig"
121 tristate "MAC-VLAN support"
123 This allows one to create virtual interfaces that map packets to
124 or from specific MAC addresses to a particular interface.
126 Macvlan devices can be added using the "ip" command from the
127 iproute2 package starting with the iproute2-2.6.23 release:
129 "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"
131 To compile this driver as a module, choose M here: the module
132 will be called macvlan.
135 tristate "MAC-VLAN based tap driver"
140 This adds a specialized tap character device driver that is based
141 on the MAC-VLAN network interface, called macvtap. A macvtap device
142 can be added in the same way as a macvlan device, using 'type
143 macvtap', and then be accessed through the tap user space interface.
145 To compile this driver as a module, choose M here: the module
146 will be called macvtap.
150 tristate "IP-VLAN support"
154 depends on NET_L3_MASTER_DEV
156 This allows one to create virtual devices off of a main interface
157 and packets will be delivered based on the dest L3 (IPv6/IPv4 addr)
158 on packets. All interfaces (including the main interface) share L2
159 making it transparent to the connected L2 switch.
161 Ipvlan devices can be added using the "ip" command from the
162 iproute2 package starting with the iproute2-3.19 release:
164 "ip link add link <main-dev> [ NAME ] type ipvlan"
166 To compile this driver as a module, choose M here: the module
167 will be called ipvlan.
170 tristate "IP-VLAN based tap driver"
175 This adds a specialized tap character device driver that is based
176 on the IP-VLAN network interface, called ipvtap. An ipvtap device
177 can be added in the same way as a ipvlan device, using 'type
178 ipvtap', and then be accessed through the tap user space interface.
180 To compile this driver as a module, choose M here: the module
181 will be called ipvtap.
184 tristate "Virtual eXtensible Local Area Network (VXLAN)"
186 select NET_UDP_TUNNEL
189 This allows one to create vxlan virtual interfaces that provide
190 Layer 2 Networks over Layer 3 Networks. VXLAN is often used
191 to tunnel virtual network infrastructure in virtualized environments.
192 For more information see:
193 http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02
195 To compile this driver as a module, choose M here: the module
196 will be called vxlan.
199 tristate "Generic Network Virtualization Encapsulation"
200 depends on INET && NET_UDP_TUNNEL
204 This allows one to create geneve virtual interfaces that provide
205 Layer 2 Networks over Layer 3 Networks. GENEVE is often used
206 to tunnel virtual network infrastructure in virtualized environments.
207 For more information see:
208 http://tools.ietf.org/html/draft-gross-geneve-02
210 To compile this driver as a module, choose M here: the module
211 will be called geneve.
214 tristate "GPRS Tunneling Protocol datapath (GTP-U)"
215 depends on INET && NET_UDP_TUNNEL
218 This allows one to create gtp virtual interfaces that provide
219 the GPRS Tunneling Protocol datapath (GTP-U). This tunneling protocol
220 is used to prevent subscribers from accessing mobile carrier core
221 network infrastructure. This driver requires a userspace software that
222 implements the signaling protocol (GTP-C) to update its PDP context
223 base, such as OpenGGSN <http://git.osmocom.org/openggsn/). This
224 tunneling protocol is implemented according to the GSM TS 09.60 and
225 3GPP TS 29.060 standards.
227 To compile this drivers as a module, choose M here: the module
231 tristate "IEEE 802.1AE MAC-level encryption (MACsec)"
237 MACsec is an encryption standard for Ethernet.
240 tristate "Network console logging support"
242 If you want to log kernel messages over the network, enable this.
243 See <file:Documentation/networking/netconsole.txt> for details.
245 config NETCONSOLE_DYNAMIC
246 bool "Dynamic reconfiguration of logging targets"
247 depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
248 !(NETCONSOLE=y && CONFIGFS_FS=m)
250 This option enables the ability to dynamically reconfigure target
251 parameters (interface, IP addresses, port numbers, MAC addresses)
252 at runtime through a userspace interface exported using configfs.
253 See <file:Documentation/networking/netconsole.txt> for details.
259 config NET_POLL_CONTROLLER
263 tristate "Virtual Ethernet over NTB Transport"
264 depends on NTB_TRANSPORT
267 tristate "RapidIO Ethernet over messaging driver support"
270 config RIONET_TX_SIZE
271 int "Number of outbound queue entries"
275 config RIONET_RX_SIZE
276 int "Number of inbound queue entries"
281 tristate "Universal TUN/TAP device driver support"
285 TUN/TAP provides packet reception and transmission for user space
286 programs. It can be viewed as a simple Point-to-Point or Ethernet
287 device, which instead of receiving packets from a physical media,
288 receives them from user space program and instead of sending packets
289 via physical media writes them to the user space program.
291 When a program opens /dev/net/tun, driver creates and registers
292 corresponding net device tunX or tapX. After a program closed above
293 devices, driver will automatically delete tunXX or tapXX device and
294 all routes corresponding to it.
296 Please read <file:Documentation/networking/tuntap.txt> for more
299 To compile this driver as a module, choose M here: the module
302 If you don't know what to use this for, you don't need it.
307 This option is selected by any driver implementing tap user space
308 interface for a virtual interface to re-use core tap functionality.
310 config TUN_VNET_CROSS_LE
311 bool "Support for cross-endian vnet headers on little-endian kernels"
314 This option allows TUN/TAP and MACVTAP device drivers in a
315 little-endian kernel to parse vnet headers that come from a
316 big-endian legacy virtio device.
318 Userspace programs can control the feature using the TUNSETVNETBE
319 and TUNGETVNETBE ioctls.
321 Unless you have a little-endian system hosting a big-endian virtual
322 machine with a legacy virtio NIC, you should say N.
325 tristate "Virtual ethernet pair device"
327 This device is a local ethernet tunnel. Devices are created in pairs.
328 When one end receives the packet it appears on its pair and vice
332 tristate "Virtio network driver"
335 This is the virtual network driver for virtio. It can be used with
336 QEMU based VMMs (like KVM or Xen). Say Y or M.
339 tristate "Virtual netlink monitoring device"
341 This option enables a monitoring net device for netlink skbs. The
342 purpose of this is to analyze netlink messages with packet sockets.
343 Thus applications like tcpdump will be able to see local netlink
344 messages if they tap into the netlink device, record pcaps for further
345 diagnostics, etc. This is mostly intended for developers or support
346 to debug netlink issues. If unsure, say N.
349 tristate "Virtual Routing and Forwarding (Lite)"
350 depends on IP_MULTIPLE_TABLES
351 depends on NET_L3_MASTER_DEV
352 depends on IPV6 || IPV6=n
353 depends on IPV6_MULTIPLE_TABLES || IPV6=n
355 This option enables the support for mapping interfaces into VRF's. The
356 support enables VRF devices.
359 tristate "Virtual vsock monitoring device"
360 depends on VHOST_VSOCK
362 This option enables a monitoring net device for vsock sockets. It is
363 mostly intended for developers or support to debug vsock issues. If
371 source "drivers/net/arcnet/Kconfig"
373 source "drivers/atm/Kconfig"
375 source "drivers/net/caif/Kconfig"
377 source "drivers/net/dsa/Kconfig"
379 source "drivers/net/ethernet/Kconfig"
381 source "drivers/net/fddi/Kconfig"
383 source "drivers/net/hippi/Kconfig"
386 tristate "General Instruments Surfboard 1000"
389 This is a driver for the General Instrument (also known as
390 NextLevel) SURFboard 1000 internal
391 cable modem. This is an ISA card which is used by a number of cable
392 TV companies to provide cable modem access. It's a one-way
393 downstream-only cable modem, meaning that your upstream net link is
394 provided by your regular phone modem.
396 At present this driver only compiles as a module, so say M here if
397 you have this card. The module will be called sb1000. Then read
398 <file:Documentation/networking/README.sb1000> for information on how
399 to use this module, as it needs special ppp scripts for establishing
400 a connection. Further documentation and the necessary scripts can be
403 <http://www.jacksonville.net/~fventuri/>
404 <http://home.adelphia.net/~siglercm/sb1000.html>
405 <http://linuxpower.cx/~cable/>
407 If you don't have this card, of course say N.
409 source "drivers/net/phy/Kconfig"
411 source "drivers/net/plip/Kconfig"
413 source "drivers/net/ppp/Kconfig"
415 source "drivers/net/slip/Kconfig"
417 source "drivers/s390/net/Kconfig"
419 source "drivers/net/usb/Kconfig"
421 source "drivers/net/wireless/Kconfig"
423 source "drivers/net/wimax/Kconfig"
425 source "drivers/net/wan/Kconfig"
427 source "drivers/net/ieee802154/Kconfig"
429 config XEN_NETDEV_FRONTEND
430 tristate "Xen network device frontend driver"
432 select XEN_XENBUS_FRONTEND
435 This driver provides support for Xen paravirtual network
436 devices exported by a Xen network driver domain (often
439 The corresponding Linux backend driver is enabled by the
440 CONFIG_XEN_NETDEV_BACKEND option.
442 If you are compiling a kernel for use as Xen guest, you
443 should say Y here. To compile this driver as a module, chose
444 M here: the module will be called xen-netfront.
446 config XEN_NETDEV_BACKEND
447 tristate "Xen backend network device"
448 depends on XEN_BACKEND
450 This driver allows the kernel to act as a Xen network driver
451 domain which exports paravirtual network devices to other
452 Xen domains. These devices can be accessed by any operating
453 system that implements a compatible front end.
455 The corresponding Linux frontend driver is enabled by the
456 CONFIG_XEN_NETDEV_FRONTEND configuration option.
458 The backend driver presents a standard network device
459 endpoint for each paravirtual network device to the driver
460 domain network stack. These can then be bridged or routed
461 etc in order to provide full network connectivity.
463 If you are compiling a kernel to run in a Xen network driver
464 domain (often this is domain 0) you should say Y here. To
465 compile this driver as a module, chose M here: the module
466 will be called xen-netback.
469 tristate "VMware VMXNET3 ethernet driver"
470 depends on PCI && INET
471 depends on !(PAGE_SIZE_64KB || ARM64_64K_PAGES || \
472 IA64_PAGE_SIZE_64KB || MICROBLAZE_64K_PAGES || \
473 PARISC_PAGE_SIZE_64KB || PPC_64K_PAGES)
475 This driver supports VMware's vmxnet3 virtual ethernet NIC.
476 To compile this driver as a module, choose M here: the
477 module will be called vmxnet3.
480 tristate "FUJITSU Extended Socket Network Device driver"
483 This driver provides support for Extended Socket network device
484 on Extended Partitioning of FUJITSU PRIMEQUEST 2000 E2 series.
486 config THUNDERBOLT_NET
487 tristate "Networking over Thunderbolt cable"
488 depends on THUNDERBOLT && INET
490 Select this if you want to create network between two
491 computers over a Thunderbolt cable. The driver supports Apple
492 ThunderboltIP protocol and allows communication with any host
493 supporting the same protocol including Windows and macOS.
495 To compile this driver a module, choose M here. The module will be
496 called thunderbolt-net.
498 source "drivers/net/hyperv/Kconfig"