basic/linux: update kernel headers from v6.14-rc1
[systemd.io.git] / man / org.freedesktop.timedate1.xml
blobd5044eac71a1b243358ac182609ba34e8b81b46b
1 <?xml version='1.0'?>
2 <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
3   "http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd" >
4 <!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
6 <refentry id="org.freedesktop.timedate1" conditional='ENABLE_TIMEDATED'
7     xmlns:xi="http://www.w3.org/2001/XInclude">
8   <refentryinfo>
9     <title>org.freedesktop.timedate1</title>
10     <productname>systemd</productname>
11   </refentryinfo>
13   <refmeta>
14     <refentrytitle>org.freedesktop.timedate1</refentrytitle>
15     <manvolnum>5</manvolnum>
16   </refmeta>
18   <refnamediv>
19     <refname>org.freedesktop.timedate1</refname>
20     <refpurpose>The D-Bus interface of systemd-timedated</refpurpose>
21   </refnamediv>
23   <refsect1>
24     <title>Introduction</title>
26     <para>
27     <citerefentry><refentrytitle>systemd-timedated.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>
28     is a system service that can be used to control the system time and related settings. This page
29     describes the D-Bus interface.</para>
30   </refsect1>
32   <refsect1>
33     <title>The D-Bus API</title>
35     <para>The service exposes the following interfaces on the bus:</para>
37     <programlisting executable="systemd-timedated" node="/org/freedesktop/timedate1" interface="org.freedesktop.timedate1">
38 node /org/freedesktop/timedate1 {
39   interface org.freedesktop.timedate1 {
40     methods:
41       SetTime(in  x usec_utc,
42               in  b relative,
43               in  b interactive);
44       SetTimezone(in  s timezone,
45                   in  b interactive);
46       SetLocalRTC(in  b local_rtc,
47                   in  b fix_system,
48                   in  b interactive);
49       SetNTP(in  b use_ntp,
50              in  b interactive);
51       ListTimezones(out as timezones);
52     properties:
53       readonly s Timezone = '...';
54       readonly b LocalRTC = ...;
55       @org.freedesktop.DBus.Property.EmitsChangedSignal("false")
56       readonly b CanNTP = ...;
57       readonly b NTP = ...;
58       @org.freedesktop.DBus.Property.EmitsChangedSignal("false")
59       readonly b NTPSynchronized = ...;
60       @org.freedesktop.DBus.Property.EmitsChangedSignal("false")
61       readonly t TimeUSec = ...;
62       @org.freedesktop.DBus.Property.EmitsChangedSignal("false")
63       readonly t RTCTimeUSec = ...;
64   };
65   interface org.freedesktop.DBus.Peer { ... };
66   interface org.freedesktop.DBus.Introspectable { ... };
67   interface org.freedesktop.DBus.Properties { ... };
69 </programlisting>
71     <!--Autogenerated cross-references for systemd.directives, do not edit-->
73     <variablelist class="dbus-interface" generated="True" extra-ref="org.freedesktop.timedate1"/>
75     <variablelist class="dbus-interface" generated="True" extra-ref="org.freedesktop.timedate1"/>
77     <variablelist class="dbus-method" generated="True" extra-ref="SetTime()"/>
79     <variablelist class="dbus-method" generated="True" extra-ref="SetTimezone()"/>
81     <variablelist class="dbus-method" generated="True" extra-ref="SetLocalRTC()"/>
83     <variablelist class="dbus-method" generated="True" extra-ref="SetNTP()"/>
85     <variablelist class="dbus-method" generated="True" extra-ref="ListTimezones()"/>
87     <variablelist class="dbus-property" generated="True" extra-ref="Timezone"/>
89     <variablelist class="dbus-property" generated="True" extra-ref="LocalRTC"/>
91     <variablelist class="dbus-property" generated="True" extra-ref="CanNTP"/>
93     <variablelist class="dbus-property" generated="True" extra-ref="NTP"/>
95     <variablelist class="dbus-property" generated="True" extra-ref="NTPSynchronized"/>
97     <variablelist class="dbus-property" generated="True" extra-ref="TimeUSec"/>
99     <variablelist class="dbus-property" generated="True" extra-ref="RTCTimeUSec"/>
101     <!--End of Autogenerated section-->
103     <refsect2>
104       <title>Methods</title>
106       <para>Use <function>SetTime()</function> to change the system clock. Pass a value of microseconds since
107       the UNIX epoch (1 Jan 1970 UTC). If <varname>relative</varname> is true, the passed usec value will be
108       added to the current system time. If it is false, the current system time will be set to the passed usec
109       value. If the system time is set with this method, the RTC will be updated as well.</para>
111       <para>Use <function>SetTimezone()</function> to set the system timezone. Pass a value like
112       <literal>Europe/Berlin</literal> to set the timezone. Valid timezones are listed in
113       <filename>/usr/share/zoneinfo/zone.tab</filename>. If the RTC is configured to be maintained in local
114       time, it will be updated accordingly.</para>
116       <para>Use <function>SetLocalRTC()</function> to control whether the RTC is in local time or UTC. It is
117       strongly recommended to maintain the RTC in UTC. However, some OSes (Windows) maintain the RTC in local
118       time, which might make it necessary to enable this feature. Note that this might create various problems as
119       daylight changes could be missed. If <varname>fix_system</varname> is <literal>true</literal>,
120       the time from the RTC is read again and the system clock is adjusted according to the new setting. If
121       <varname>fix_system</varname> is <literal>false</literal>, the system time is written to the RTC
122       taking the new setting into account. Use <varname>fix_system=true</varname> in installers and livecds
123       where the RTC is probably more reliable than the system time. Use <varname>fix_system=false</varname>
124       in configuration UIs that are run during normal operation and where the system clock is probably more
125       reliable than the RTC.</para>
127       <para>Use <function>SetNTP()</function> to control whether the system clock is synchronized with the
128       network using <filename>systemd-timesyncd</filename>. This will enable and start or disable and stop
129       the chosen time synchronization service.</para>
131       <para><function>ListTimezones()</function> returns a list of time zones known on the local system as an
132       array of names (<literal>["Africa/Abidjan", "Africa/Accra", ..., "UTC"]</literal>).</para>
133     </refsect2>
135     <refsect2>
136       <title>Properties</title>
138       <para><varname>Timezone</varname> shows the currently configured time zone.
139       <varname>LocalRTC</varname> shows whether the RTC is configured to use UTC (false), or the local time
140       zone (true). <varname>CanNTP</varname> shows whether a service to perform time synchronization over the
141       network is available, and <varname>NTP</varname> shows whether such a service is enabled.</para>
143       <para><varname>NTPSynchronized</varname> shows whether the kernel reports the time as synchronized
144       (c.f.
145       <citerefentry project="man-pages"><refentrytitle>adjtimex</refentrytitle><manvolnum>3</manvolnum></citerefentry>).
146       <varname>TimeUSec</varname> and <varname>RTCTimeUSec</varname> show the current time on the system and
147       in the RTC. The purpose of those three properties is to allow remote clients to access this information
148       over D-Bus. Local clients can access the information directly.</para>
150       <para>Whenever the <varname>Timezone</varname> and <varname>LocalRTC</varname> settings are changed via
151       the daemon, <function>PropertyChanged</function> signals are sent out to which clients can subscribe.
152       </para>
154       <para>Note that this service will not inform you about system time changes. Use
155       <citerefentry project="man-pages"><refentrytitle>timerfd</refentrytitle><manvolnum>3</manvolnum></citerefentry>
156       with <constant>CLOCK_REALTIME</constant> and <constant>TFD_TIMER_CANCEL_ON_SET</constant> for that.
157       </para>
158     </refsect2>
160     <refsect2>
161       <title>Security</title>
163       <para>The <varname>interactive</varname> boolean parameters can be used to control whether
164       <ulink url="https://www.freedesktop.org/software/polkit/docs/latest/">polkit</ulink>
165       should interactively ask the user for authentication credentials if required.</para>
167       <para>The polkit action for <function>SetTimezone()</function> is
168       <interfacename>org.freedesktop.timedate1.set-timezone</interfacename>. For
169       <function>SetLocalRTC()</function> it is
170       <interfacename>org.freedesktop.timedate1.set-local-rtc</interfacename>, for
171       <function>SetTime()</function> it is <interfacename>org.freedesktop.timedate1.set-time</interfacename>
172       and for <function>SetNTP()</function> it is
173       <interfacename>org.freedesktop.timedate1.set-ntp</interfacename>.
174       <function>ListTimezones()</function> does not require any privileges.
175       </para>
176     </refsect2>
177   </refsect1>
179   <refsect1>
180     <title>Examples</title>
182     <example>
183       <title>Introspect <interfacename>org.freedesktop.timedate1</interfacename> on the bus</title>
185       <programlisting>
186 $ gdbus introspect --system \
187   --dest org.freedesktop.timedate1 \
188   --object-path /org/freedesktop/timedate1
189 </programlisting>
190     </example>
191   </refsect1>
193   <xi:include href="org.freedesktop.locale1.xml" xpointer="versioning"/>
195   <refsect1>
196     <title>See Also</title>
197     <para><simplelist type="inline">
198       <member><citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
199       <member><citerefentry><refentrytitle>systemd-timedate.service</refentrytitle><manvolnum>8</manvolnum></citerefentry></member>
200       <member><citerefentry><refentrytitle>timedatectl.service</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
201       <member><ulink url="https://lists.freedesktop.org/archives/systemd-devel/2011-May/002526.html">More information on how the system clock and RTC interact</ulink></member>
202     </simplelist></para>
203   </refsect1>
204 </refentry>