8322 nl: misleading-indentation
[unleashed/tickless.git] / usr / src / cmd / fm / dicts / PCI.po
blobc8a63c56e993bbd0e7428ba0c03393710e31df03
2 # Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
3 # Use is subject to license terms.
5 # CDDL HEADER START
7 # The contents of this file are subject to the terms of the
8 # Common Development and Distribution License (the "License").
9 # You may not use this file except in compliance with the License.
11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 # or http://www.opensolaris.org/os/licensing.
13 # See the License for the specific language governing permissions
14 # and limitations under the License.
16 # When distributing Covered Code, include this CDDL HEADER in each
17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 # If applicable, add the following below this CDDL HEADER, with the
19 # fields enclosed by brackets "[]" replaced with your own identifying
20 # information: Portions Copyright [yyyy] [name of copyright owner]
22 # CDDL HEADER END
24 # DO NOT EDIT -- this file is generated by the Event Registry.
27 # code: PCI-8000-0C
28 # keys: defect.io.pci.driver
30 msgid "PCI-8000-0C.type"
31 msgstr "Fault"
32 msgid "PCI-8000-0C.severity"
33 msgstr "Critical"
34 msgid "PCI-8000-0C.description"
35 msgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
36 msgid "PCI-8000-0C.response"
37 msgstr "One or more of device instances may be disabled."
38 msgid "PCI-8000-0C.impact"
39 msgstr "Loss of services provided by the device instances associated with this problem."
40 msgid "PCI-8000-0C.action"
41 msgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
43 # code: PCI-8000-1Q
44 # keys: fault.io.pci.bus
46 msgid "PCI-8000-1Q.type"
47 msgstr "Fault"
48 msgid "PCI-8000-1Q.severity"
49 msgstr "Critical"
50 msgid "PCI-8000-1Q.description"
51 msgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
52 msgid "PCI-8000-1Q.response"
53 msgstr "One or more device instances may be disabled."
54 msgid "PCI-8000-1Q.impact"
55 msgstr "Loss of services provided by the device instances associated with this fault."
56 msgid "PCI-8000-1Q.action"
57 msgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
59 # code: PCI-8000-24
60 # keys: defect.io.pci.driver fault.io.pci.bus
62 msgid "PCI-8000-24.type"
63 msgstr "Fault"
64 msgid "PCI-8000-24.severity"
65 msgstr "Critical"
66 msgid "PCI-8000-24.description"
67 msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
68 msgid "PCI-8000-24.response"
69 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
70 msgid "PCI-8000-24.impact"
71 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
72 msgid "PCI-8000-24.action"
73 msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
75 # code: PCI-8000-3R
76 # keys: fault.io.pci.device
78 msgid "PCI-8000-3R.type"
79 msgstr "Fault"
80 msgid "PCI-8000-3R.severity"
81 msgstr "Critical"
82 msgid "PCI-8000-3R.description"
83 msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
84 msgid "PCI-8000-3R.response"
85 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
86 msgid "PCI-8000-3R.impact"
87 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
88 msgid "PCI-8000-3R.action"
89 msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
91 # code: PCI-8000-42
92 # keys: defect.io.pci.driver fault.io.pci.device
94 msgid "PCI-8000-42.type"
95 msgstr "Fault"
96 msgid "PCI-8000-42.severity"
97 msgstr "Critical"
98 msgid "PCI-8000-42.description"
99 msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
100 msgid "PCI-8000-42.response"
101 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
102 msgid "PCI-8000-42.impact"
103 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
104 msgid "PCI-8000-42.action"
105 msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
107 # code: PCI-8000-5X
108 # keys: fault.io.pci.bus fault.io.pci.device
110 msgid "PCI-8000-5X.type"
111 msgstr "Fault"
112 msgid "PCI-8000-5X.severity"
113 msgstr "Critical"
114 msgid "PCI-8000-5X.description"
115 msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
116 msgid "PCI-8000-5X.response"
117 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
118 msgid "PCI-8000-5X.impact"
119 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
120 msgid "PCI-8000-5X.action"
121 msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
123 # code: PCI-8000-6E
124 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
126 msgid "PCI-8000-6E.type"
127 msgstr "Fault"
128 msgid "PCI-8000-6E.severity"
129 msgstr "Critical"
130 msgid "PCI-8000-6E.description"
131 msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
132 msgid "PCI-8000-6E.response"
133 msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
134 msgid "PCI-8000-6E.impact"
135 msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
136 msgid "PCI-8000-6E.action"
137 msgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
139 # code: PCI-8000-7J
140 # keys: fault.io.pci.device-interr
142 msgid "PCI-8000-7J.type"
143 msgstr "Fault"
144 msgid "PCI-8000-7J.severity"
145 msgstr "Critical"
146 msgid "PCI-8000-7J.description"
147 msgstr "An unrecoverable problem was detected for a PCI device.\n  Refer to %s for more information."
148 msgid "PCI-8000-7J.response"
149 msgstr "One or more device instances may be disabled\n"
150 msgid "PCI-8000-7J.impact"
151 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
152 msgid "PCI-8000-7J.action"
153 msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
155 # code: PCI-8000-8S
156 # keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
158 msgid "PCI-8000-8S.type"
159 msgstr "Fault"
160 msgid "PCI-8000-8S.severity"
161 msgstr "Critical"
162 msgid "PCI-8000-8S.description"
163 msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
164 msgid "PCI-8000-8S.response"
165 msgstr "One or more device instances may be disabled\n"
166 msgid "PCI-8000-8S.impact"
167 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
168 msgid "PCI-8000-8S.action"
169 msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
171 # code: PCI-8000-95
172 # keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
174 msgid "PCI-8000-95.type"
175 msgstr "Fault"
176 msgid "PCI-8000-95.severity"
177 msgstr "Major"
178 msgid "PCI-8000-95.description"
179 msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
180 msgid "PCI-8000-95.response"
181 msgstr "One or more device instances may be disabled\n"
182 msgid "PCI-8000-95.impact"
183 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
184 msgid "PCI-8000-95.action"
185 msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
187 # code: PCI-8000-AP
188 # keys: fault.io.pci.device-interr fault.io.pci.device-invreq
190 msgid "PCI-8000-AP.type"
191 msgstr "Fault"
192 msgid "PCI-8000-AP.severity"
193 msgstr "Major"
194 msgid "PCI-8000-AP.description"
195 msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
196 msgid "PCI-8000-AP.response"
197 msgstr "One or more device instances may be disabled\n"
198 msgid "PCI-8000-AP.impact"
199 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
200 msgid "PCI-8000-AP.action"
201 msgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact Sun for support.\n"
203 # code: PCI-8000-CA
204 # keys: fault.io.pci.device-noresp
206 msgid "PCI-8000-CA.type"
207 msgstr "Fault"
208 msgid "PCI-8000-CA.severity"
209 msgstr "Major"
210 msgid "PCI-8000-CA.description"
211 msgstr "A device is failing to respond\n  Refer to %s for more information."
212 msgid "PCI-8000-CA.response"
213 msgstr "One or more device instances may be disabled\n"
214 msgid "PCI-8000-CA.impact"
215 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
216 msgid "PCI-8000-CA.action"
217 msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
219 # code: PCI-8000-DH
220 # keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf
222 msgid "PCI-8000-DH.type"
223 msgstr "Fault"
224 msgid "PCI-8000-DH.severity"
225 msgstr "Major"
226 msgid "PCI-8000-DH.description"
227 msgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n  Refer to %s for more information."
228 msgid "PCI-8000-DH.response"
229 msgstr "One or more device instances may be disabled\n"
230 msgid "PCI-8000-DH.impact"
231 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
232 msgid "PCI-8000-DH.action"
233 msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
235 # code: PCI-8000-ED
236 # keys: fault.io.pci.device-interr-corr
238 msgid "PCI-8000-ED.type"
239 msgstr "Fault"
240 msgid "PCI-8000-ED.severity"
241 msgstr "Major"
242 msgid "PCI-8000-ED.description"
243 msgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n  Refer to %s for more information."
244 msgid "PCI-8000-ED.response"
245 msgstr "One or more device instances may be disabled\n"
246 msgid "PCI-8000-ED.impact"
247 msgstr "Possible loss of services provided by the device instances associated with this fault\n"
248 msgid "PCI-8000-ED.action"
249 msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
251 # code: PCI-8000-FY
252 # keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg
254 msgid "PCI-8000-FY.type"
255 msgstr "Fault"
256 msgid "PCI-8000-FY.severity"
257 msgstr "Major"
258 msgid "PCI-8000-FY.description"
259 msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
260 msgid "PCI-8000-FY.response"
261 msgstr "None\n"
262 msgid "PCI-8000-FY.impact"
263 msgstr "Degraded services provided by the device instances associated with this fault\n"
264 msgid "PCI-8000-FY.action"
265 msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact Sun for support.\n"
267 # code: PCI-8000-G3
268 # keys: fault.io.pci.device-interr-deg
270 msgid "PCI-8000-G3.type"
271 msgstr "Fault"
272 msgid "PCI-8000-G3.severity"
273 msgstr "Major"
274 msgid "PCI-8000-G3.description"
275 msgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
276 msgid "PCI-8000-G3.response"
277 msgstr "None\n"
278 msgid "PCI-8000-G3.impact"
279 msgstr "Degraded services provided by the device instances associated with this fault\n"
280 msgid "PCI-8000-G3.action"
281 msgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact Sun for support.\n"
283 # code: PCI-8000-HR
284 # keys: fault.io.pci.fw_corrupt
286 msgid "PCI-8000-HR.type"
287 msgstr "Fault"
288 msgid "PCI-8000-HR.severity"
289 msgstr "Major"
290 msgid "PCI-8000-HR.description"
291 msgstr "A firmware corruption was detected for a PCI device.\n  Refer to %s for more information."
292 msgid "PCI-8000-HR.response"
293 msgstr "One or more device instances may be disabled.\n"
294 msgid "PCI-8000-HR.impact"
295 msgstr "Degraded services provided by the device instances associated with this fault.\n"
296 msgid "PCI-8000-HR.action"
297 msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n"
299 # code: PCI-8000-J4
300 # keys: fault.io.pci.fw_mismatch
302 msgid "PCI-8000-J4.type"
303 msgstr "Fault"
304 msgid "PCI-8000-J4.severity"
305 msgstr "Major"
306 msgid "PCI-8000-J4.description"
307 msgstr "A firmware version mismatch was detected for a PCI device.\n  Refer to %s for more information."
308 msgid "PCI-8000-J4.response"
309 msgstr "One or more device instances may be disabled.\n"
310 msgid "PCI-8000-J4.impact"
311 msgstr "Degraded services provided by the device instances associated with this fault.\n"
312 msgid "PCI-8000-J4.action"
313 msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n"