2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
6 # The contents of this file are subject to the terms of the
7 # Common Development and Distribution License (the "License").
8 # You may not use this file except in compliance with the License.
10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11 # or http://www.opensolaris.org/os/licensing.
12 # See the License for the specific language governing permissions
13 # and limitations under the License.
15 # When distributing Covered Code, include this CDDL HEADER in each
16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17 # If applicable, add the following below this CDDL HEADER, with the
18 # fields enclosed by brackets "[]" replaced with your own identifying
19 # information: Portions Copyright [yyyy] [name of copyright owner]
24 # DO NOT EDIT -- this file is generated by the Event Registry.
27 # code: STORAGE-8000-1Q
28 # keys: fault.config.fan-fail
30 msgid "STORAGE-8000-1Q.type"
32 msgid "STORAGE-8000-1Q.severity"
34 msgid "STORAGE-8000-1Q.description"
35 msgstr "The minimum number of required chassis fans '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
36 msgid "STORAGE-8000-1Q.response"
37 msgstr "The service required LED on the chassis will be illuminated."
38 msgid "STORAGE-8000-1Q.impact"
39 msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
40 msgid "STORAGE-8000-1Q.action"
41 msgstr "Check that the minimum required number of fans are configured."
43 # code: STORAGE-8000-24
44 # keys: fault.config.fantray-fail
46 msgid "STORAGE-8000-24.type"
48 msgid "STORAGE-8000-24.severity"
50 msgid "STORAGE-8000-24.description"
51 msgstr "The minimum number of required chassis fan trays '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
52 msgid "STORAGE-8000-24.response"
53 msgstr "The service required LED on the chassis will be illuminated."
54 msgid "STORAGE-8000-24.impact"
55 msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
56 msgid "STORAGE-8000-24.action"
57 msgstr "Check that the minimum required number of fan trays are configured."
59 # code: STORAGE-8000-3R
60 # keys: fault.config.psu-fail
62 msgid "STORAGE-8000-3R.type"
64 msgid "STORAGE-8000-3R.severity"
66 msgid "STORAGE-8000-3R.description"
67 msgstr "The minimum number of required chassis power supplies '%<fault-list[0].resource.hc-specific.min-required>' were not detected. The missing devices are '%<fault-list[0].resource.hc-specific.devices>'."
68 msgid "STORAGE-8000-3R.response"
69 msgstr "The service required LED on the chassis will be illuminated."
70 msgid "STORAGE-8000-3R.impact"
71 msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved."
72 msgid "STORAGE-8000-3R.action"
73 msgstr "Check that the minimum required number of power supplies are configured."
75 # code: STORAGE-8000-42
76 # keys: fault.device.controller.fail
78 msgid "STORAGE-8000-42.type"
80 msgid "STORAGE-8000-42.severity"
82 msgid "STORAGE-8000-42.description"
83 msgstr "Controller card '%<fault-list[0].location>' is not functioning correctly."
84 msgid "STORAGE-8000-42.response"
85 msgstr "The service required LED on the chassis will be illuminated."
86 msgid "STORAGE-8000-42.impact"
87 msgstr "The SAS fabric may be in a degraded state."
88 msgid "STORAGE-8000-42.action"
89 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
91 # code: STORAGE-8000-5X
92 # keys: fault.device.ethernet.fail
94 msgid "STORAGE-8000-5X.type"
96 msgid "STORAGE-8000-5X.severity"
98 msgid "STORAGE-8000-5X.description"
99 msgstr "An out-of-band management interface failure has occurred on '%<fault-list[0].location>'."
100 msgid "STORAGE-8000-5X.response"
101 msgstr "The service required LED on the chassis will be illuminated."
102 msgid "STORAGE-8000-5X.impact"
103 msgstr "The SAS fabric may be in a degraded state. User data storage is still available."
104 msgid "STORAGE-8000-5X.action"
105 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
107 # code: STORAGE-8000-6E
108 # keys: fault.device.fan.fail
110 msgid "STORAGE-8000-6E.type"
112 msgid "STORAGE-8000-6E.severity"
114 msgid "STORAGE-8000-6E.description"
115 msgstr "A fan on '%<fault-list[0].location>' is not functioning correctly."
116 msgid "STORAGE-8000-6E.response"
117 msgstr "The service required LED on the chassis will be illuminated."
118 msgid "STORAGE-8000-6E.impact"
119 msgstr "The chassis may be getting inadequate cooling. If the problem persists, components may overheat and the chassis may shutdown."
120 msgid "STORAGE-8000-6E.action"
121 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
123 # code: STORAGE-8000-7J
124 # keys: fault.device.psu.fail
126 msgid "STORAGE-8000-7J.type"
128 msgid "STORAGE-8000-7J.severity"
130 msgid "STORAGE-8000-7J.description"
131 msgstr "Power supply '%<fault-list[0].location>' is not functioning correctly."
132 msgid "STORAGE-8000-7J.response"
133 msgstr "The service required LED on the chassis will be illuminated."
134 msgid "STORAGE-8000-7J.impact"
135 msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown."
136 msgid "STORAGE-8000-7J.action"
137 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
139 # code: STORAGE-8000-8S
140 # keys: fault.device.sas-expander.fail
142 msgid "STORAGE-8000-8S.type"
144 msgid "STORAGE-8000-8S.severity"
146 msgid "STORAGE-8000-8S.description"
147 msgstr "A SAS expander on '%<fault-list[0].location>' is not functioning correctly."
148 msgid "STORAGE-8000-8S.response"
149 msgstr "The service required LED on the chassis will be illuminated."
150 msgid "STORAGE-8000-8S.impact"
151 msgstr "The SAS fabric is in a degraded state. User data storage may be degraded or unavailable."
152 msgid "STORAGE-8000-8S.action"
153 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
155 # code: STORAGE-8000-95
156 # keys: fault.device.unusable-chassis-id
158 msgid "STORAGE-8000-95.type"
160 msgid "STORAGE-8000-95.severity"
162 msgid "STORAGE-8000-95.description"
163 msgstr "The chassis ID was determined to be unusable."
164 msgid "STORAGE-8000-95.response"
165 msgstr "The service required LED on the chassis will be illuminated."
166 msgid "STORAGE-8000-95.impact"
167 msgstr "The SAS fabric is down, and user data storage is unavailable."
168 msgid "STORAGE-8000-95.action"
169 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
171 # code: STORAGE-8000-AP
172 # keys: fault.io.i2c.fail
174 msgid "STORAGE-8000-AP.type"
176 msgid "STORAGE-8000-AP.severity"
178 msgid "STORAGE-8000-AP.description"
179 msgstr "An I2C bus on '%<fault-list[0].location>' is not functioning correctly."
180 msgid "STORAGE-8000-AP.response"
181 msgstr "The service required LED on the chassis will be illuminated."
182 msgid "STORAGE-8000-AP.impact"
183 msgstr "The system is in an unknown state."
184 msgid "STORAGE-8000-AP.action"
185 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
187 # code: STORAGE-8000-CA
188 # keys: fault.io.sas.log.fatal
190 msgid "STORAGE-8000-CA.type"
192 msgid "STORAGE-8000-CA.severity"
194 msgid "STORAGE-8000-CA.description"
195 msgstr "A fatal error has been detected by a SAS expander on '%<fault-list[0].location>' requiring it to reset."
196 msgid "STORAGE-8000-CA.response"
197 msgstr "The service required LED on the chassis will be illuminated."
198 msgid "STORAGE-8000-CA.impact"
199 msgstr "The SAS expander is not functioning correctly. The SAS fabric will be in a degraded state while the expander resets. Downstream devices may be inaccessible."
200 msgid "STORAGE-8000-CA.action"
201 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
203 # code: STORAGE-8000-DH
204 # keys: fault.io.sas.log.non-fatal
206 msgid "STORAGE-8000-DH.type"
208 msgid "STORAGE-8000-DH.severity"
210 msgid "STORAGE-8000-DH.description"
211 msgstr "A non-fatal error has been detected by a SAS expander on '%<fault-list[0].location>'."
212 msgid "STORAGE-8000-DH.response"
213 msgstr "The service required LED on the chassis will be illuminated."
214 msgid "STORAGE-8000-DH.impact"
215 msgstr "The SAS expander may not be functioning correctly. The SAS fabric may be in a degraded state. Downstream devices may be inaccessible."
216 msgid "STORAGE-8000-DH.action"
217 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
219 # code: STORAGE-8000-ED
220 # keys: fault.power.ext-fail
222 msgid "STORAGE-8000-ED.type"
224 msgid "STORAGE-8000-ED.severity"
226 msgid "STORAGE-8000-ED.description"
227 msgstr "A power failure external to the chassis has occurred."
228 msgid "STORAGE-8000-ED.response"
230 msgid "STORAGE-8000-ED.impact"
231 msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown."
232 msgid "STORAGE-8000-ED.action"
233 msgstr "Check that external AC power is available and that all the power cords are plugged into the chassis power supplies."
235 # code: STORAGE-8000-FY
236 # keys: fault.power.fail
238 msgid "STORAGE-8000-FY.type"
240 msgid "STORAGE-8000-FY.severity"
242 msgid "STORAGE-8000-FY.description"
243 msgstr "A power failure has occurred on '%<fault-list[0].location>'."
244 msgid "STORAGE-8000-FY.response"
245 msgstr "The service required LED on the chassis will be illuminated."
246 msgid "STORAGE-8000-FY.impact"
247 msgstr "A device in the chassis may be getting inadequate power. Subsequent loss of the device may force the chassis to shutdown."
248 msgid "STORAGE-8000-FY.action"
249 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
251 # code: STORAGE-8000-G3
252 # keys: fault.sensor.read-fail
254 msgid "STORAGE-8000-G3.type"
256 msgid "STORAGE-8000-G3.severity"
258 msgid "STORAGE-8000-G3.description"
259 msgstr "An attempt to read a sensor on '%<fault-list[0].location>' failed."
260 msgid "STORAGE-8000-G3.response"
261 msgstr "The service required LED on the chassis will be illuminated."
262 msgid "STORAGE-8000-G3.impact"
263 msgstr "Data from the affected sensor will be unavailable. Data from other sensors may be used instead if available."
264 msgid "STORAGE-8000-G3.action"
265 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
267 # code: STORAGE-8000-HR
268 # keys: fault.sp.fail
270 msgid "STORAGE-8000-HR.type"
272 msgid "STORAGE-8000-HR.severity"
274 msgid "STORAGE-8000-HR.description"
275 msgstr "A Service Processor on '%<fault-list[0].location>' is not functioning correctly."
276 msgid "STORAGE-8000-HR.response"
277 msgstr "The service required LED on the chassis will be illuminated."
278 msgid "STORAGE-8000-HR.impact"
279 msgstr "The SAS fabric may be in a degraded state."
280 msgid "STORAGE-8000-HR.action"
281 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
283 # code: STORAGE-8000-J4
284 # keys: fault.sp.unavailable
286 msgid "STORAGE-8000-J4.type"
288 msgid "STORAGE-8000-J4.severity"
290 msgid "STORAGE-8000-J4.description"
291 msgstr "A Service Processor has detected that its peer is unavailable."
292 msgid "STORAGE-8000-J4.response"
293 msgstr "The service required LED on the chassis will be illuminated."
294 msgid "STORAGE-8000-J4.impact"
295 msgstr "IMP_FAB_MB_DEG"
296 msgid "STORAGE-8000-J4.action"
297 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
299 # code: STORAGE-8000-KQ
300 # keys: fault.sp.svc-fail
302 msgid "STORAGE-8000-KQ.type"
304 msgid "STORAGE-8000-KQ.severity"
306 msgid "STORAGE-8000-KQ.description"
307 msgstr "A Service Processor software service failure has occurred on '%<fault-list[0].location>'. The service which restarted was '%<fault-list[0].resource.hc-specific.service>'."
308 msgid "STORAGE-8000-KQ.response"
309 msgstr "The service required LED on the chassis will be illuminated."
310 msgid "STORAGE-8000-KQ.impact"
311 msgstr "The SAS fabric may be in a degraded state. User data storage is still available."
312 msgid "STORAGE-8000-KQ.action"
313 msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI."
315 # code: STORAGE-8000-LC
316 # keys: fault.temp.fail
318 msgid "STORAGE-8000-LC.type"
320 msgid "STORAGE-8000-LC.severity"
322 msgid "STORAGE-8000-LC.description"
323 msgstr "Ambient temperature is outside of normal operating range."
324 msgid "STORAGE-8000-LC.response"
325 msgstr "The service required LED on the chassis will be illuminated."
326 msgid "STORAGE-8000-LC.impact"
327 msgstr "A device in the chassis may be overheating. Subsequent loss of the device may force the chassis to shutdown."
328 msgid "STORAGE-8000-LC.action"
329 msgstr "Check that the ambient temperature is adequately cool, and none of the chassis air inlets are blocked."