2 # Copyright 2009 Sun Microsystems, Inc. All rights reserved.
3 # Use is subject to license terms.
7 # The contents of this file are subject to the terms of the
8 # Common Development and Distribution License (the "License").
9 # You may not use this file except in compliance with the License.
11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 # or http://www.opensolaris.org/os/licensing.
13 # See the License for the specific language governing permissions
14 # and limitations under the License.
16 # When distributing Covered Code, include this CDDL HEADER in each
17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 # If applicable, add the following below this CDDL HEADER, with the
19 # fields enclosed by brackets "[]" replaced with your own identifying
20 # information: Portions Copyright [yyyy] [name of copyright owner]
24 # DO NOT EDIT -- this file is generated by the Event Registry.
28 # keys: fault.cpu.ultraSPARC-T1.ireg
30 msgid "SUN4V-8000-1S.type"
32 msgid "SUN4V-8000-1S.severity"
34 msgid "SUN4V-8000-1S.description"
35 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
36 msgid "SUN4V-8000-1S.response"
37 msgstr "The fault manager will attempt to remove the affected CPU from service."
38 msgid "SUN4V-8000-1S.impact"
39 msgstr "System performance may be affected."
40 msgid "SUN4V-8000-1S.action"
41 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
44 # keys: fault.cpu.ultraSPARC-T1.freg
46 msgid "SUN4V-8000-2A.type"
48 msgid "SUN4V-8000-2A.severity"
50 msgid "SUN4V-8000-2A.description"
51 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
52 msgid "SUN4V-8000-2A.response"
54 msgid "SUN4V-8000-2A.impact"
55 msgstr "System performance may be affected."
56 msgid "SUN4V-8000-2A.action"
57 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
60 # keys: fault.cpu.ultraSPARC-T1.itlb
62 msgid "SUN4V-8000-3P.type"
64 msgid "SUN4V-8000-3P.severity"
66 msgid "SUN4V-8000-3P.description"
67 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
68 msgid "SUN4V-8000-3P.response"
69 msgstr "The fault manager will attempt to remove the affected CPU from service."
70 msgid "SUN4V-8000-3P.impact"
71 msgstr "System performance may be affected.\n"
72 msgid "SUN4V-8000-3P.action"
73 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
76 # keys: fault.cpu.ultraSPARC-T1.dtlb
78 msgid "SUN4V-8000-4D.type"
80 msgid "SUN4V-8000-4D.severity"
82 msgid "SUN4V-8000-4D.description"
83 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
84 msgid "SUN4V-8000-4D.response"
85 msgstr "The fault manager will attempt to remove the affected CPU from service."
86 msgid "SUN4V-8000-4D.impact"
87 msgstr "System performance may be affected.\n"
88 msgid "SUN4V-8000-4D.action"
89 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
92 # keys: fault.cpu.ultraSPARC-T1.icache
94 msgid "SUN4V-8000-5H.type"
96 msgid "SUN4V-8000-5H.severity"
98 msgid "SUN4V-8000-5H.description"
99 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
100 msgid "SUN4V-8000-5H.response"
101 msgstr "The fault manager will attempt to remove the affected CPU from service."
102 msgid "SUN4V-8000-5H.impact"
103 msgstr "System performance may be affected.\n"
104 msgid "SUN4V-8000-5H.action"
105 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
107 # code: SUN4V-8000-63
108 # keys: fault.cpu.ultraSPARC-T1.dcache
110 msgid "SUN4V-8000-63.type"
112 msgid "SUN4V-8000-63.severity"
114 msgid "SUN4V-8000-63.description"
115 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
116 msgid "SUN4V-8000-63.response"
117 msgstr "The fault manager will attempt to remove the affected CPU from service."
118 msgid "SUN4V-8000-63.impact"
119 msgstr "System performance may be affected.\n"
120 msgid "SUN4V-8000-63.action"
121 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
123 # code: SUN4V-8000-7Y
124 # keys: fault.cpu.ultraSPARC-T1.mau
126 msgid "SUN4V-8000-7Y.type"
128 msgid "SUN4V-8000-7Y.severity"
130 msgid "SUN4V-8000-7Y.description"
131 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
132 msgid "SUN4V-8000-7Y.response"
134 msgid "SUN4V-8000-7Y.impact"
135 msgstr "System performance may be affected.\n"
136 msgid "SUN4V-8000-7Y.action"
137 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
139 # code: SUN4V-8000-8Q
140 # keys: fault.cpu.ultraSPARC-T1.l2cachedata
142 msgid "SUN4V-8000-8Q.type"
144 msgid "SUN4V-8000-8Q.severity"
146 msgid "SUN4V-8000-8Q.description"
147 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
148 msgid "SUN4V-8000-8Q.response"
150 msgid "SUN4V-8000-8Q.impact"
151 msgstr "System performance may be affected.\n"
152 msgid "SUN4V-8000-8Q.action"
153 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
155 # code: SUN4V-8000-9C
156 # keys: fault.cpu.ultraSPARC-T1.l2cachetag
158 msgid "SUN4V-8000-9C.type"
160 msgid "SUN4V-8000-9C.severity"
162 msgid "SUN4V-8000-9C.description"
163 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
164 msgid "SUN4V-8000-9C.response"
166 msgid "SUN4V-8000-9C.impact"
167 msgstr "System performance may be affected.\n"
168 msgid "SUN4V-8000-9C.action"
169 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
171 # code: SUN4V-8000-AR
172 # keys: fault.cpu.ultraSPARC-T1.l2cachectl
174 msgid "SUN4V-8000-AR.type"
176 msgid "SUN4V-8000-AR.severity"
178 msgid "SUN4V-8000-AR.description"
179 msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information."
180 msgid "SUN4V-8000-AR.response"
182 msgid "SUN4V-8000-AR.impact"
183 msgstr "System performance may be affected.\n"
184 msgid "SUN4V-8000-AR.action"
185 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
187 # code: SUN4V-8000-C4
188 # keys: fault.memory.page
190 msgid "SUN4V-8000-C4.type"
192 msgid "SUN4V-8000-C4.severity"
194 msgid "SUN4V-8000-C4.description"
195 msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information."
196 msgid "SUN4V-8000-C4.response"
197 msgstr "An attempt will be made to remove this memory page from service."
198 msgid "SUN4V-8000-C4.impact"
199 msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
200 msgid "SUN4V-8000-C4.action"
201 msgstr "No repair action is recommended at this time."
203 # code: SUN4V-8000-DX
204 # keys: fault.memory.dimm
206 msgid "SUN4V-8000-DX.type"
208 msgid "SUN4V-8000-DX.severity"
210 msgid "SUN4V-8000-DX.description"
211 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information."
212 msgid "SUN4V-8000-DX.response"
213 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached."
214 msgid "SUN4V-8000-DX.impact"
215 msgstr "Total system memory capacity has been reduced."
216 msgid "SUN4V-8000-DX.action"
217 msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty' to identify the memory module."
219 # code: SUN4V-8000-E2
220 # keys: fault.memory.bank
222 msgid "SUN4V-8000-E2.type"
224 msgid "SUN4V-8000-E2.severity"
226 msgid "SUN4V-8000-E2.description"
227 msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information."
228 msgid "SUN4V-8000-E2.response"
229 msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
230 msgid "SUN4V-8000-E2.impact"
231 msgstr "Total system memory capacity will be reduced as pages are retired."
232 msgid "SUN4V-8000-E2.action"
233 msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
235 # code: SUN4V-8000-FJ
236 # keys: fault.memory.link-c
238 msgid "SUN4V-8000-FJ.type"
240 msgid "SUN4V-8000-FJ.severity"
242 msgid "SUN4V-8000-FJ.description"
243 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
244 msgid "SUN4V-8000-FJ.response"
245 msgstr "No automated response.\n"
246 msgid "SUN4V-8000-FJ.impact"
247 msgstr "System performance may be impacted.\n"
248 msgid "SUN4V-8000-FJ.action"
249 msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n"
251 # code: SUN4V-8000-GE
252 # keys: fault.cpu.ultraSPARC-T2.ireg
254 msgid "SUN4V-8000-GE.type"
256 msgid "SUN4V-8000-GE.severity"
258 msgid "SUN4V-8000-GE.description"
259 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
260 msgid "SUN4V-8000-GE.response"
261 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
262 msgid "SUN4V-8000-GE.impact"
263 msgstr "System performance may be affected. \n"
264 msgid "SUN4V-8000-GE.action"
265 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
267 # code: SUN4V-8000-HP
268 # keys: fault.cpu.ultraSPARC-T2.freg
270 msgid "SUN4V-8000-HP.type"
272 msgid "SUN4V-8000-HP.severity"
274 msgid "SUN4V-8000-HP.description"
275 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
276 msgid "SUN4V-8000-HP.response"
277 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
278 msgid "SUN4V-8000-HP.impact"
279 msgstr "System performance may be affected. \n"
280 msgid "SUN4V-8000-HP.action"
281 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
283 # code: SUN4V-8000-JA
284 # keys: fault.cpu.ultraSPARC-T2.misc_reg
286 msgid "SUN4V-8000-JA.type"
288 msgid "SUN4V-8000-JA.severity"
290 msgid "SUN4V-8000-JA.description"
291 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
292 msgid "SUN4V-8000-JA.response"
293 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
294 msgid "SUN4V-8000-JA.impact"
295 msgstr "System performance may be affected. \n"
296 msgid "SUN4V-8000-JA.action"
297 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
299 # code: SUN4V-8000-KS
300 # keys: fault.cpu.ultraSPARC-T2.itlb
302 msgid "SUN4V-8000-KS.type"
304 msgid "SUN4V-8000-KS.severity"
306 msgid "SUN4V-8000-KS.description"
307 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
308 msgid "SUN4V-8000-KS.response"
309 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
310 msgid "SUN4V-8000-KS.impact"
311 msgstr "System performance is likely to be affected. \n"
312 msgid "SUN4V-8000-KS.action"
313 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
315 # code: SUN4V-8000-L5
316 # keys: fault.cpu.ultraSPARC-T2.dtlb
318 msgid "SUN4V-8000-L5.type"
320 msgid "SUN4V-8000-L5.severity"
322 msgid "SUN4V-8000-L5.description"
323 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
324 msgid "SUN4V-8000-L5.response"
325 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
326 msgid "SUN4V-8000-L5.impact"
327 msgstr "System performance is likely to be affected. \n"
328 msgid "SUN4V-8000-L5.action"
329 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
331 # code: SUN4V-8000-MY
332 # keys: fault.cpu.ultraSPARC-T2.icache
334 msgid "SUN4V-8000-MY.type"
336 msgid "SUN4V-8000-MY.severity"
338 msgid "SUN4V-8000-MY.description"
339 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
340 msgid "SUN4V-8000-MY.response"
341 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
342 msgid "SUN4V-8000-MY.impact"
343 msgstr "System performance is likely to be affected. \n"
344 msgid "SUN4V-8000-MY.action"
345 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
347 # code: SUN4V-8000-N3
348 # keys: fault.cpu.ultraSPARC-T2.dcache
350 msgid "SUN4V-8000-N3.type"
352 msgid "SUN4V-8000-N3.severity"
354 msgid "SUN4V-8000-N3.description"
355 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
356 msgid "SUN4V-8000-N3.response"
357 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
358 msgid "SUN4V-8000-N3.impact"
359 msgstr "System performance is likely to be affected. \n"
360 msgid "SUN4V-8000-N3.action"
361 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
363 # code: SUN4V-8000-PH
364 # keys: fault.cpu.ultraSPARC-T2.mau
366 msgid "SUN4V-8000-PH.type"
368 msgid "SUN4V-8000-PH.severity"
370 msgid "SUN4V-8000-PH.description"
371 msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n Refer to %s for more information."
372 msgid "SUN4V-8000-PH.response"
373 msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
374 msgid "SUN4V-8000-PH.impact"
375 msgstr "System performance is likely to be affected. \n"
376 msgid "SUN4V-8000-PH.action"
377 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
379 # code: SUN4V-8000-QD
380 # keys: fault.cpu.ultraSPARC-T2.l2data-c
382 msgid "SUN4V-8000-QD.type"
384 msgid "SUN4V-8000-QD.severity"
386 msgid "SUN4V-8000-QD.description"
387 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information."
388 msgid "SUN4V-8000-QD.response"
389 msgstr "No automated response.\n"
390 msgid "SUN4V-8000-QD.impact"
391 msgstr "System performance is likely to be affected. \n"
392 msgid "SUN4V-8000-QD.action"
393 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
395 # code: SUN4V-8000-R4
396 # keys: fault.cpu.ultraSPARC-T2.l2cachetag
398 msgid "SUN4V-8000-R4.type"
400 msgid "SUN4V-8000-R4.severity"
402 msgid "SUN4V-8000-R4.description"
403 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information."
404 msgid "SUN4V-8000-R4.response"
405 msgstr "No automated response.\n"
406 msgid "SUN4V-8000-R4.impact"
407 msgstr "System performance is likely to be affected. \n"
408 msgid "SUN4V-8000-R4.action"
409 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
411 # code: SUN4V-8000-SR
412 # keys: fault.cpu.ultraSPARC-T2.l2cachectl
414 msgid "SUN4V-8000-SR.type"
416 msgid "SUN4V-8000-SR.severity"
418 msgid "SUN4V-8000-SR.description"
419 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information."
420 msgid "SUN4V-8000-SR.response"
421 msgstr "No automated response.\n"
422 msgid "SUN4V-8000-SR.impact"
423 msgstr "System performance is likely to be affected. System may be unstable.\n"
424 msgid "SUN4V-8000-SR.action"
425 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
427 # code: SUN4V-8000-TC
428 # keys: fault.memory.link-u
430 msgid "SUN4V-8000-TC.type"
432 msgid "SUN4V-8000-TC.severity"
434 msgid "SUN4V-8000-TC.description"
435 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information."
436 msgid "SUN4V-8000-TC.response"
437 msgstr "No automated response.\n"
438 msgid "SUN4V-8000-TC.impact"
439 msgstr "System performance may be impacted.\n"
440 msgid "SUN4V-8000-TC.action"
441 msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n"
443 # code: SUN4V-8000-UQ
444 # keys: fault.cpu.ultraSPARC-T2.l2data-u
446 msgid "SUN4V-8000-UQ.type"
448 msgid "SUN4V-8000-UQ.severity"
450 msgid "SUN4V-8000-UQ.description"
451 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
452 msgid "SUN4V-8000-UQ.response"
453 msgstr "No automated response.\n"
454 msgid "SUN4V-8000-UQ.impact"
455 msgstr "System performance is likely to be affected. \n"
456 msgid "SUN4V-8000-UQ.action"
457 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
459 # code: SUN4V-8000-VE
460 # keys: fault.cpu.ultraSPARC-T1.l2data-c
462 msgid "SUN4V-8000-VE.type"
464 msgid "SUN4V-8000-VE.severity"
466 msgid "SUN4V-8000-VE.description"
467 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information."
468 msgid "SUN4V-8000-VE.response"
469 msgstr "No automated response.\n"
470 msgid "SUN4V-8000-VE.impact"
471 msgstr "System performance is likely to be affected. \n"
472 msgid "SUN4V-8000-VE.action"
473 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
475 # code: SUN4V-8000-WJ
476 # keys: fault.cpu.ultraSPARC-T1.l2data-u
478 msgid "SUN4V-8000-WJ.type"
480 msgid "SUN4V-8000-WJ.severity"
482 msgid "SUN4V-8000-WJ.description"
483 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
484 msgid "SUN4V-8000-WJ.response"
485 msgstr "No automated response.\n"
486 msgid "SUN4V-8000-WJ.impact"
487 msgstr "System performance is likely to be affected. \n"
488 msgid "SUN4V-8000-WJ.action"
489 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
491 # code: SUN4V-8000-X2
492 # keys: fault.memory.datapath
494 msgid "SUN4V-8000-X2.type"
496 msgid "SUN4V-8000-X2.severity"
498 msgid "SUN4V-8000-X2.description"
499 msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information."
500 msgid "SUN4V-8000-X2.response"
501 msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
502 msgid "SUN4V-8000-X2.impact"
503 msgstr "System performance and stability may be affected. \n"
504 msgid "SUN4V-8000-X2.action"
505 msgstr "Contact your service provider for further diagnosis.\n"
507 # code: SUN4V-8000-YX
508 # keys: fault.io.n2.ncu
510 msgid "SUN4V-8000-YX.type"
512 msgid "SUN4V-8000-YX.severity"
514 msgid "SUN4V-8000-YX.description"
515 msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information."
516 msgid "SUN4V-8000-YX.response"
517 msgstr "One or more device instances may be disabled\n"
518 msgid "SUN4V-8000-YX.impact"
519 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
520 msgid "SUN4V-8000-YX.action"
521 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
523 # code: SUN4V-8001-02
524 # keys: fault.io.n2.dmu
526 msgid "SUN4V-8001-02.type"
528 msgid "SUN4V-8001-02.severity"
530 msgid "SUN4V-8001-02.description"
531 msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information."
532 msgid "SUN4V-8001-02.response"
533 msgstr "One or more device instances may be disabled\n"
534 msgid "SUN4V-8001-02.impact"
535 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
536 msgid "SUN4V-8001-02.action"
537 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
539 # code: SUN4V-8001-1X
540 # keys: fault.io.n2.niu
542 msgid "SUN4V-8001-1X.type"
544 msgid "SUN4V-8001-1X.severity"
546 msgid "SUN4V-8001-1X.description"
547 msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information."
548 msgid "SUN4V-8001-1X.response"
549 msgstr "One or more device instances may be disabled\n"
550 msgid "SUN4V-8001-1X.impact"
551 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
552 msgid "SUN4V-8001-1X.action"
553 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
555 # code: SUN4V-8001-2E
556 # keys: fault.io.n2.siu
558 msgid "SUN4V-8001-2E.type"
560 msgid "SUN4V-8001-2E.severity"
562 msgid "SUN4V-8001-2E.description"
563 msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information."
564 msgid "SUN4V-8001-2E.response"
565 msgstr "One or more device instances may be disabled\n"
566 msgid "SUN4V-8001-2E.impact"
567 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
568 msgid "SUN4V-8001-2E.action"
569 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
571 # code: SUN4V-8001-3J
572 # keys: fault.io.n2.soc
574 msgid "SUN4V-8001-3J.type"
576 msgid "SUN4V-8001-3J.severity"
578 msgid "SUN4V-8001-3J.description"
579 msgstr "A problem was detected in N2's SOC\n Refer to %s for more information."
580 msgid "SUN4V-8001-3J.response"
581 msgstr "One or more device instances may be disabled\n"
582 msgid "SUN4V-8001-3J.impact"
583 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
584 msgid "SUN4V-8001-3J.action"
585 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
587 # code: SUN4V-8001-4C
588 # keys: fault.io.n2.crossbar
590 msgid "SUN4V-8001-4C.type"
592 msgid "SUN4V-8001-4C.severity"
594 msgid "SUN4V-8001-4C.description"
595 msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information."
596 msgid "SUN4V-8001-4C.response"
597 msgstr "One or more device instances may be disabled\n"
598 msgid "SUN4V-8001-4C.impact"
599 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
600 msgid "SUN4V-8001-4C.action"
601 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
603 # code: SUN4V-8001-5Q
604 # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
606 msgid "SUN4V-8001-5Q.type"
608 msgid "SUN4V-8001-5Q.severity"
610 msgid "SUN4V-8001-5Q.description"
611 msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n Refer to %s for more information."
612 msgid "SUN4V-8001-5Q.response"
613 msgstr "One or more device instances may be disabled\n"
614 msgid "SUN4V-8001-5Q.impact"
615 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
616 msgid "SUN4V-8001-5Q.action"
617 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
619 # code: SUN4V-8001-64
620 # keys: fault.io.vf.ncx
622 msgid "SUN4V-8001-64.type"
624 msgid "SUN4V-8001-64.severity"
626 msgid "SUN4V-8001-64.description"
627 msgstr "An uncorrectable problem was detected in the NCX subsystem.\n Refer to %s for more information."
628 msgid "SUN4V-8001-64.response"
629 msgstr "One or more device instances may be disabled\n"
630 msgid "SUN4V-8001-64.impact"
631 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
632 msgid "SUN4V-8001-64.action"
633 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
635 # code: SUN4V-8001-7R
636 # keys: fault.memory.link-f
638 msgid "SUN4V-8001-7R.type"
640 msgid "SUN4V-8001-7R.severity"
642 msgid "SUN4V-8001-7R.description"
643 msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. A lane failover has taken place.\n Refer to %s for more information."
644 msgid "SUN4V-8001-7R.response"
645 msgstr "No automated response.\n"
646 msgid "SUN4V-8001-7R.impact"
647 msgstr "System performance may be impacted.\n"
648 msgid "SUN4V-8001-7R.action"
649 msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n"
651 # code: SUN4V-8001-8H
652 # keys: fault.cpu.ultraSPARC-T2plus.ireg
654 msgid "SUN4V-8001-8H.type"
656 msgid "SUN4V-8001-8H.severity"
658 msgid "SUN4V-8001-8H.description"
659 msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
660 msgid "SUN4V-8001-8H.response"
661 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
662 msgid "SUN4V-8001-8H.impact"
663 msgstr "System performance may be affected. \n"
664 msgid "SUN4V-8001-8H.action"
665 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
667 # code: SUN4V-8001-9D
668 # keys: fault.cpu.ultraSPARC-T2plus.freg
670 msgid "SUN4V-8001-9D.type"
672 msgid "SUN4V-8001-9D.severity"
674 msgid "SUN4V-8001-9D.description"
675 msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
676 msgid "SUN4V-8001-9D.response"
677 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
678 msgid "SUN4V-8001-9D.impact"
679 msgstr "System performance may be affected. \n"
680 msgid "SUN4V-8001-9D.action"
681 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
683 # code: SUN4V-8001-AY
684 # keys: fault.cpu.ultraSPARC-T2plus.misc_reg
686 msgid "SUN4V-8001-AY.type"
688 msgid "SUN4V-8001-AY.severity"
690 msgid "SUN4V-8001-AY.description"
691 msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
692 msgid "SUN4V-8001-AY.response"
693 msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
694 msgid "SUN4V-8001-AY.impact"
695 msgstr "System performance may be affected. \n"
696 msgid "SUN4V-8001-AY.action"
697 msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
699 # code: SUN4V-8001-C3
700 # keys: fault.cpu.ultraSPARC-T2plus.itlb
702 msgid "SUN4V-8001-C3.type"
704 msgid "SUN4V-8001-C3.severity"
706 msgid "SUN4V-8001-C3.description"
707 msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
708 msgid "SUN4V-8001-C3.response"
709 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
710 msgid "SUN4V-8001-C3.impact"
711 msgstr "System performance is likely to be affected. \n"
712 msgid "SUN4V-8001-C3.action"
713 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
715 # code: SUN4V-8001-DS
716 # keys: fault.cpu.ultraSPARC-T2plus.dtlb
718 msgid "SUN4V-8001-DS.type"
720 msgid "SUN4V-8001-DS.severity"
722 msgid "SUN4V-8001-DS.description"
723 msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
724 msgid "SUN4V-8001-DS.response"
725 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
726 msgid "SUN4V-8001-DS.impact"
727 msgstr "System performance is likely to be affected. \n"
728 msgid "SUN4V-8001-DS.action"
729 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
731 # code: SUN4V-8001-E5
732 # keys: fault.cpu.ultraSPARC-T2plus.icache
734 msgid "SUN4V-8001-E5.type"
736 msgid "SUN4V-8001-E5.severity"
738 msgid "SUN4V-8001-E5.description"
739 msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
740 msgid "SUN4V-8001-E5.response"
741 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
742 msgid "SUN4V-8001-E5.impact"
743 msgstr "System performance is likely to be affected. \n"
744 msgid "SUN4V-8001-E5.action"
745 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
747 # code: SUN4V-8001-FP
748 # keys: fault.cpu.ultraSPARC-T2plus.dcache
750 msgid "SUN4V-8001-FP.type"
752 msgid "SUN4V-8001-FP.severity"
754 msgid "SUN4V-8001-FP.description"
755 msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
756 msgid "SUN4V-8001-FP.response"
757 msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
758 msgid "SUN4V-8001-FP.impact"
759 msgstr "System performance is likely to be affected. \n"
760 msgid "SUN4V-8001-FP.action"
761 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
763 # code: SUN4V-8001-GA
764 # keys: fault.cpu.ultraSPARC-T2plus.mau
766 msgid "SUN4V-8001-GA.type"
768 msgid "SUN4V-8001-GA.severity"
770 msgid "SUN4V-8001-GA.description"
771 msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information."
772 msgid "SUN4V-8001-GA.response"
773 msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
774 msgid "SUN4V-8001-GA.impact"
775 msgstr "System performance is likely to be affected. \n"
776 msgid "SUN4V-8001-GA.action"
777 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
779 # code: SUN4V-8001-HJ
780 # keys: fault.cpu.ultraSPARC-T2plus.l2data-c
782 msgid "SUN4V-8001-HJ.type"
784 msgid "SUN4V-8001-HJ.severity"
786 msgid "SUN4V-8001-HJ.description"
787 msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information."
788 msgid "SUN4V-8001-HJ.response"
789 msgstr "No automated response.\n"
790 msgid "SUN4V-8001-HJ.impact"
791 msgstr "System performance is likely to be affected. \n"
792 msgid "SUN4V-8001-HJ.action"
793 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
795 # code: SUN4V-8001-JE
796 # keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
798 msgid "SUN4V-8001-JE.type"
800 msgid "SUN4V-8001-JE.severity"
802 msgid "SUN4V-8001-JE.description"
803 msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information."
804 msgid "SUN4V-8001-JE.response"
805 msgstr "No automated response.\n"
806 msgid "SUN4V-8001-JE.impact"
807 msgstr "System performance is likely to be affected. \n"
808 msgid "SUN4V-8001-JE.action"
809 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
811 # code: SUN4V-8001-KX
812 # keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
814 msgid "SUN4V-8001-KX.type"
816 msgid "SUN4V-8001-KX.severity"
818 msgid "SUN4V-8001-KX.description"
819 msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information."
820 msgid "SUN4V-8001-KX.response"
821 msgstr "No automated response.\n"
822 msgid "SUN4V-8001-KX.impact"
823 msgstr "System performance is likely to be affected. System may be unstable.\n"
824 msgid "SUN4V-8001-KX.action"
825 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
827 # code: SUN4V-8001-L2
828 # keys: fault.cpu.ultraSPARC-T2plus.l2data-u
830 msgid "SUN4V-8001-L2.type"
832 msgid "SUN4V-8001-L2.severity"
834 msgid "SUN4V-8001-L2.description"
835 msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information."
836 msgid "SUN4V-8001-L2.response"
837 msgstr "No automated response.\n"
838 msgid "SUN4V-8001-L2.impact"
839 msgstr "System performance is likely to be affected. \n"
840 msgid "SUN4V-8001-L2.action"
841 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
843 # code: SUN4V-8001-MR
844 # keys: fault.cpu.ultraSPARC-T2plus.lfu-f
846 msgid "SUN4V-8001-MR.type"
848 msgid "SUN4V-8001-MR.severity"
850 msgid "SUN4V-8001-MR.description"
851 msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n Refer to %s for more information."
852 msgid "SUN4V-8001-MR.response"
853 msgstr "No other automated response.\n"
854 msgid "SUN4V-8001-MR.impact"
855 msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
856 msgid "SUN4V-8001-MR.action"
857 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
859 # code: SUN4V-8001-N4
860 # keys: fault.cpu.ultraSPARC-T2plus.lfu-p
862 msgid "SUN4V-8001-N4.type"
864 msgid "SUN4V-8001-N4.severity"
866 msgid "SUN4V-8001-N4.description"
867 msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n Refer to %s for more information."
868 msgid "SUN4V-8001-N4.response"
869 msgstr "No automated response.\n"
870 msgid "SUN4V-8001-N4.impact"
871 msgstr "The system has most likely taken a fatal reset.\n"
872 msgid "SUN4V-8001-N4.action"
873 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
875 # code: SUN4V-8001-PQ
876 # keys: fault.cpu.ultraSPARC-T2plus.lfu-u
878 msgid "SUN4V-8001-PQ.type"
880 msgid "SUN4V-8001-PQ.severity"
882 msgid "SUN4V-8001-PQ.description"
883 msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n Refer to %s for more information."
884 msgid "SUN4V-8001-PQ.response"
885 msgstr "No automated response.\n"
886 msgid "SUN4V-8001-PQ.impact"
887 msgstr "The system's integrity is seriously compromised.\n"
888 msgid "SUN4V-8001-PQ.action"
889 msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
891 # code: SUN4V-8001-QC
892 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
894 msgid "SUN4V-8001-QC.type"
896 msgid "SUN4V-8001-QC.severity"
898 msgid "SUN4V-8001-QC.description"
899 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n Refer to %s for more information."
900 msgid "SUN4V-8001-QC.response"
901 msgstr "No automated reponse.\n"
902 msgid "SUN4V-8001-QC.impact"
903 msgstr "The system's integrity is compromised.\n"
904 msgid "SUN4V-8001-QC.action"
905 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
907 # code: SUN4V-8001-R3
908 # keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
910 msgid "SUN4V-8001-R3.type"
912 msgid "SUN4V-8001-R3.severity"
914 msgid "SUN4V-8001-R3.description"
915 msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n Refer to %s for more information."
916 msgid "SUN4V-8001-R3.response"
917 msgstr "No automated reponse.\n"
918 msgid "SUN4V-8001-R3.impact"
919 msgstr "The system's integrity is compromised.\n"
920 msgid "SUN4V-8001-R3.action"
921 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
923 # code: SUN4V-8001-SY
924 # keys: fault.cpu.ultraSPARC-T2plus.chip
926 msgid "SUN4V-8001-SY.type"
928 msgid "SUN4V-8001-SY.severity"
930 msgid "SUN4V-8001-SY.description"
931 msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n Refer to %s for more information."
932 msgid "SUN4V-8001-SY.response"
933 msgstr "No automated reponse.\n"
934 msgid "SUN4V-8001-SY.impact"
935 msgstr "The system's integrity is seriously compromised.\n"
936 msgid "SUN4V-8001-SY.action"
937 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
939 # code: SUN4V-8001-TD
940 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
942 msgid "SUN4V-8001-TD.type"
944 msgid "SUN4V-8001-TD.severity"
946 msgid "SUN4V-8001-TD.description"
947 msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n Refer to %s for more information."
948 msgid "SUN4V-8001-TD.response"
949 msgstr "No automated reponse.\n"
950 msgid "SUN4V-8001-TD.impact"
951 msgstr "The system's integrity is seriously compromised.\n"
952 msgid "SUN4V-8001-TD.action"
953 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
955 # code: SUN4V-8001-UH
956 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
958 msgid "SUN4V-8001-UH.type"
960 msgid "SUN4V-8001-UH.severity"
962 msgid "SUN4V-8001-UH.description"
963 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n Refer to %s for more information."
964 msgid "SUN4V-8001-UH.response"
965 msgstr "No automated reponse.\n"
966 msgid "SUN4V-8001-UH.impact"
967 msgstr "The system's performance may be impacted.\n"
968 msgid "SUN4V-8001-UH.action"
969 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
971 # code: SUN4V-8001-VA
972 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
974 msgid "SUN4V-8001-VA.type"
976 msgid "SUN4V-8001-VA.severity"
978 msgid "SUN4V-8001-VA.description"
979 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n Refer to %s for more information."
980 msgid "SUN4V-8001-VA.response"
981 msgstr "No automated reponse.\n"
982 msgid "SUN4V-8001-VA.impact"
983 msgstr "The system's integrity is seriously compromised.\n"
984 msgid "SUN4V-8001-VA.action"
985 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
987 # code: SUN4V-8001-WP
988 # keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
990 msgid "SUN4V-8001-WP.type"
992 msgid "SUN4V-8001-WP.severity"
994 msgid "SUN4V-8001-WP.description"
995 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n Refer to %s for more information."
996 msgid "SUN4V-8001-WP.response"
997 msgstr "No automated reponse.\n"
998 msgid "SUN4V-8001-WP.impact"
999 msgstr "The system's integrity is seriously compromised.\n"
1000 msgid "SUN4V-8001-WP.action"
1001 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1003 # code: SUN4V-8001-X5
1004 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
1006 msgid "SUN4V-8001-X5.type"
1008 msgid "SUN4V-8001-X5.severity"
1010 msgid "SUN4V-8001-X5.description"
1011 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n Refer to %s for more information."
1012 msgid "SUN4V-8001-X5.response"
1013 msgstr "No automated reponse.\n"
1014 msgid "SUN4V-8001-X5.impact"
1015 msgstr "The system's performance may be compromised.\n"
1016 msgid "SUN4V-8001-X5.action"
1017 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1019 # code: SUN4V-8001-YS
1020 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
1022 msgid "SUN4V-8001-YS.type"
1024 msgid "SUN4V-8001-YS.severity"
1026 msgid "SUN4V-8001-YS.description"
1027 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n Refer to %s for more information."
1028 msgid "SUN4V-8001-YS.response"
1029 msgstr "No automated reponse.\n"
1030 msgid "SUN4V-8001-YS.impact"
1031 msgstr "The system's integrity may be seriously compromised.\n"
1032 msgid "SUN4V-8001-YS.action"
1033 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1035 # code: SUN4V-8002-0C
1036 # keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1038 msgid "SUN4V-8002-0C.type"
1040 msgid "SUN4V-8002-0C.severity"
1042 msgid "SUN4V-8002-0C.description"
1043 msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n Refer to %s for more information."
1044 msgid "SUN4V-8002-0C.response"
1045 msgstr "No automated reponse.\n"
1046 msgid "SUN4V-8002-0C.impact"
1047 msgstr "The system's performance may be impacted.\n"
1048 msgid "SUN4V-8002-0C.action"
1049 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1051 # code: SUN4V-8002-1Q
1052 # keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1054 msgid "SUN4V-8002-1Q.type"
1056 msgid "SUN4V-8002-1Q.severity"
1058 msgid "SUN4V-8002-1Q.description"
1059 msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n Refer to %s for more information."
1060 msgid "SUN4V-8002-1Q.response"
1061 msgstr "No automated reponse.\n"
1062 msgid "SUN4V-8002-1Q.impact"
1063 msgstr "The system's performance may be impacted.\n"
1064 msgid "SUN4V-8002-1Q.action"
1065 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1067 # code: SUN4V-8002-24
1068 # keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
1070 msgid "SUN4V-8002-24.type"
1072 msgid "SUN4V-8002-24.severity"
1074 msgid "SUN4V-8002-24.description"
1075 msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n Refer to %s for more information."
1076 msgid "SUN4V-8002-24.response"
1077 msgstr "No automated reponse.\n"
1078 msgid "SUN4V-8002-24.impact"
1079 msgstr "The system's integrity is seriously compromised.\n"
1080 msgid "SUN4V-8002-24.action"
1081 msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1083 # code: SUN4V-8002-3R
1084 # keys: fault.memory.dimm-page-retires-excessive
1086 msgid "SUN4V-8002-3R.type"
1088 msgid "SUN4V-8002-3R.severity"
1090 msgid "SUN4V-8002-3R.description"
1091 msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n Refer to %s for more information."
1092 msgid "SUN4V-8002-3R.response"
1093 msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
1094 msgid "SUN4V-8002-3R.impact"
1095 msgstr "Total system memory capacity has been reduced.\n"
1096 msgid "SUN4V-8002-3R.action"
1097 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1099 # code: SUN4V-8002-42
1100 # keys: fault.memory.dimm-ue-imminent
1102 msgid "SUN4V-8002-42.type"
1104 msgid "SUN4V-8002-42.severity"
1106 msgid "SUN4V-8002-42.description"
1107 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information."
1108 msgid "SUN4V-8002-42.response"
1109 msgstr "None at this time.\n"
1110 msgid "SUN4V-8002-42.impact"
1111 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1112 msgid "SUN4V-8002-42.action"
1113 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1115 # code: SUN4V-8002-5X
1116 # keys: fault.memory.dram-ue-imminent
1118 msgid "SUN4V-8002-5X.type"
1120 msgid "SUN4V-8002-5X.severity"
1122 msgid "SUN4V-8002-5X.description"
1123 msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information."
1124 msgid "SUN4V-8002-5X.response"
1125 msgstr "None at this time.\n"
1126 msgid "SUN4V-8002-5X.impact"
1127 msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1128 msgid "SUN4V-8002-5X.action"
1129 msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1131 # code: SUN4V-8002-6E
1132 # keys: fault.cpu.generic-sparc.strand
1134 msgid "SUN4V-8002-6E.type"
1136 msgid "SUN4V-8002-6E.severity"
1138 msgid "SUN4V-8002-6E.description"
1139 msgstr "The number of correctable errors associated with this strand has exceeded acceptable levels.\n Refer to %s for more information."
1140 msgid "SUN4V-8002-6E.response"
1141 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1142 msgid "SUN4V-8002-6E.impact"
1143 msgstr "System performance may be affected. \n"
1144 msgid "SUN4V-8002-6E.action"
1145 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1147 # code: SUN4V-8002-7J
1148 # keys: fault.cpu.generic-sparc.strand-nr
1150 msgid "SUN4V-8002-7J.type"
1152 msgid "SUN4V-8002-7J.severity"
1154 msgid "SUN4V-8002-7J.description"
1155 msgstr "The number of correctable errors in internal memory associated with this strand have exceeded acceptable levels.\n Refer to %s for more information."
1156 msgid "SUN4V-8002-7J.response"
1157 msgstr "The system may attempt to avoid using internal memory associated with this\nstrand.\n"
1158 msgid "SUN4V-8002-7J.impact"
1159 msgstr "System performance may be affected. \n"
1160 msgid "SUN4V-8002-7J.action"
1161 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1163 # code: SUN4V-8002-8S
1164 # keys: fault.cpu.generic-sparc.strand-uc
1166 msgid "SUN4V-8002-8S.type"
1168 msgid "SUN4V-8002-8S.severity"
1170 msgid "SUN4V-8002-8S.description"
1171 msgstr "This strand has encountered an uncorrectable error.\n Refer to %s for more information."
1172 msgid "SUN4V-8002-8S.response"
1173 msgstr "The fault manager will attempt to remove the affected strand\nfrom service.\n"
1174 msgid "SUN4V-8002-8S.impact"
1175 msgstr "System performance may be affected. \n"
1176 msgid "SUN4V-8002-8S.action"
1177 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1179 # code: SUN4V-8002-95
1180 # keys: fault.cpu.generic-sparc.strand-uc-nr
1182 msgid "SUN4V-8002-95.type"
1184 msgid "SUN4V-8002-95.severity"
1186 msgid "SUN4V-8002-95.description"
1187 msgstr "Internal memory associated with this strand has encountered an uncorrectable error.\n Refer to %s for more information."
1188 msgid "SUN4V-8002-95.response"
1189 msgstr "The system may attempt to avoid using internal memory associated with\nthis strand.\n"
1190 msgid "SUN4V-8002-95.impact"
1191 msgstr "System performance may be affected. \n"
1192 msgid "SUN4V-8002-95.action"
1193 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1195 # code: SUN4V-8002-AP
1196 # keys: fault.cpu.generic-sparc.core
1198 msgid "SUN4V-8002-AP.type"
1200 msgid "SUN4V-8002-AP.severity"
1202 msgid "SUN4V-8002-AP.description"
1203 msgstr "The number of correctable errors associated with this core has exceeded acceptable levels.\n Refer to %s for more information."
1204 msgid "SUN4V-8002-AP.response"
1205 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1206 msgid "SUN4V-8002-AP.impact"
1207 msgstr "System performance may be affected. \n"
1208 msgid "SUN4V-8002-AP.action"
1209 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1211 # code: SUN4V-8002-CA
1212 # keys: fault.cpu.generic-sparc.core-nr
1214 msgid "SUN4V-8002-CA.type"
1216 msgid "SUN4V-8002-CA.severity"
1218 msgid "SUN4V-8002-CA.description"
1219 msgstr "The number of correctable errors in internal memory associated with this core have exceeded acceptable levels.\n Refer to %s for more information."
1220 msgid "SUN4V-8002-CA.response"
1221 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1222 msgid "SUN4V-8002-CA.impact"
1223 msgstr "System performance may be affected. \n"
1224 msgid "SUN4V-8002-CA.action"
1225 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1227 # code: SUN4V-8002-DH
1228 # keys: fault.cpu.generic-sparc.core-uc
1230 msgid "SUN4V-8002-DH.type"
1232 msgid "SUN4V-8002-DH.severity"
1234 msgid "SUN4V-8002-DH.description"
1235 msgstr "This core has encountered an uncorrectable error.\n Refer to %s for more information."
1236 msgid "SUN4V-8002-DH.response"
1237 msgstr "The fault manager will attempt to remove all strands associated with\nthis resource from service.\n"
1238 msgid "SUN4V-8002-DH.impact"
1239 msgstr "System performance may be affected. \n"
1240 msgid "SUN4V-8002-DH.action"
1241 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1243 # code: SUN4V-8002-ED
1244 # keys: fault.cpu.generic-sparc.core-uc-nr
1246 msgid "SUN4V-8002-ED.type"
1248 msgid "SUN4V-8002-ED.severity"
1250 msgid "SUN4V-8002-ED.description"
1251 msgstr "An uncorrectable error has occurred in internal memory associated with this core.\n Refer to %s for more information."
1252 msgid "SUN4V-8002-ED.response"
1253 msgstr "The system may attempt to avoid using internal memory associated with this\ncore.\n"
1254 msgid "SUN4V-8002-ED.impact"
1255 msgstr "System performance may be affected. \n"
1256 msgid "SUN4V-8002-ED.action"
1257 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1259 # code: SUN4V-8002-FY
1260 # keys: fault.cpu.generic-sparc.chip
1262 msgid "SUN4V-8002-FY.type"
1264 msgid "SUN4V-8002-FY.severity"
1266 msgid "SUN4V-8002-FY.description"
1267 msgstr "The number of chip-level correctable errors has exceeded acceptable levels.\n Refer to %s for more information."
1268 msgid "SUN4V-8002-FY.response"
1269 msgstr "No automated response.\n"
1270 msgid "SUN4V-8002-FY.impact"
1271 msgstr "System performance may be affected. \n"
1272 msgid "SUN4V-8002-FY.action"
1273 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1275 # code: SUN4V-8002-G3
1276 # keys: fault.cpu.generic-sparc.chip-nr
1278 msgid "SUN4V-8002-G3.type"
1280 msgid "SUN4V-8002-G3.severity"
1282 msgid "SUN4V-8002-G3.description"
1283 msgstr "The number of correctable errors in internal memory associated with this chip have exceeded acceptable levels.\n Refer to %s for more information."
1284 msgid "SUN4V-8002-G3.response"
1285 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1286 msgid "SUN4V-8002-G3.impact"
1287 msgstr "System performance may be affected. \n"
1288 msgid "SUN4V-8002-G3.action"
1289 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1291 # code: SUN4V-8002-HR
1292 # keys: fault.cpu.generic-sparc.chip-uc
1294 msgid "SUN4V-8002-HR.type"
1296 msgid "SUN4V-8002-HR.severity"
1298 msgid "SUN4V-8002-HR.description"
1299 msgstr "This chip has encountered a chip-level uncorrectable error.\n Refer to %s for more information."
1300 msgid "SUN4V-8002-HR.response"
1301 msgstr "The system will attempt to retire all strands in this chip.\n"
1302 msgid "SUN4V-8002-HR.impact"
1303 msgstr "System performance may be affected. \n"
1304 msgid "SUN4V-8002-HR.action"
1305 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1307 # code: SUN4V-8002-J4
1308 # keys: fault.cpu.generic-sparc.chip-uc-nr
1310 msgid "SUN4V-8002-J4.type"
1312 msgid "SUN4V-8002-J4.severity"
1314 msgid "SUN4V-8002-J4.description"
1315 msgstr "Internal memory associated with this chip has encountered an uncorrectable\nerror.\n Refer to %s for more information."
1316 msgid "SUN4V-8002-J4.response"
1317 msgstr "The system may attempt to avoid using internal memory associated with this\nchip.\n"
1318 msgid "SUN4V-8002-J4.impact"
1319 msgstr "System performance may be affected. \n"
1320 msgid "SUN4V-8002-J4.action"
1321 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1323 # code: SUN4V-8002-KQ
1324 # keys: fault.cpu.generic-sparc.c2c
1326 msgid "SUN4V-8002-KQ.type"
1328 msgid "SUN4V-8002-KQ.severity"
1330 msgid "SUN4V-8002-KQ.description"
1331 msgstr "The number of chip-to-chip recoverable errors has exceeded acceptable levels.\n Refer to %s for more information."
1332 msgid "SUN4V-8002-KQ.response"
1333 msgstr "No automated response.\n"
1334 msgid "SUN4V-8002-KQ.impact"
1335 msgstr "System performance may be affected.\n"
1336 msgid "SUN4V-8002-KQ.action"
1337 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1339 # code: SUN4V-8002-LC
1340 # keys: fault.cpu.generic-sparc.c2c-failover
1342 msgid "SUN4V-8002-LC.type"
1344 msgid "SUN4V-8002-LC.severity"
1346 msgid "SUN4V-8002-LC.description"
1347 msgstr "A CRC error has occurred in the interconnect between two CPU chips.\nWhile no data has been lost, a lane failover has taken place.\n Refer to %s for more information."
1348 msgid "SUN4V-8002-LC.response"
1349 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1350 msgid "SUN4V-8002-LC.impact"
1351 msgstr "The system's capacity to correct transmission errors between CPU chips\nhas been reduced.\n"
1352 msgid "SUN4V-8002-LC.action"
1353 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1355 # code: SUN4V-8002-MJ
1356 # keys: fault.cpu.generic-sparc.c2c-uc
1358 msgid "SUN4V-8002-MJ.type"
1360 msgid "SUN4V-8002-MJ.severity"
1362 msgid "SUN4V-8002-MJ.description"
1363 msgstr "A chip-to-chip unrecoverable CRC error has occurred.\n Refer to %s for more information."
1364 msgid "SUN4V-8002-MJ.response"
1365 msgstr "The system has halted in order to prevent corruption of data.\nNo further automated response.\n"
1366 msgid "SUN4V-8002-MJ.impact"
1367 msgstr "The system halts and must be restarted. The integrity of this system has\nbeen compromised.\n"
1368 msgid "SUN4V-8002-MJ.action"
1369 msgstr "Schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1371 # code: SUN4V-8002-NE
1372 # keys: fault.memory.memlink
1374 msgid "SUN4V-8002-NE.type"
1376 msgid "SUN4V-8002-NE.severity"
1378 msgid "SUN4V-8002-NE.description"
1379 msgstr "Recoverable CRC errors have occurred in the interconnect between a\nmemory buffer and its memory controller. No data has been lost;\nhowever, the number of CRC errors associated with this memory buffer-controller\npair has exceeded acceptable levels.\n Refer to %s for more information."
1380 msgid "SUN4V-8002-NE.response"
1381 msgstr "The system has recovered from the CRC errors.\n"
1382 msgid "SUN4V-8002-NE.impact"
1383 msgstr "System performance may be impacted by a slight reduction in effective\nmemory bandwidth.\n"
1384 msgid "SUN4V-8002-NE.action"
1385 msgstr "At a convenient time, schedule a repair procedure to replace the affected resource(s), the identity of which can be determined using 'fmadm faulty'.\n"
1387 # code: SUN4V-8002-PX
1388 # keys: fault.memory.memlink-failover
1390 msgid "SUN4V-8002-PX.type"
1392 msgid "SUN4V-8002-PX.severity"
1394 msgid "SUN4V-8002-PX.description"
1395 msgstr "A CRC error has occurred in the interconnect between a memory buffer and\nits memory controller. While no data has been lost, a lane failover\nhas taken place.\n Refer to %s for more information."
1396 msgid "SUN4V-8002-PX.response"
1397 msgstr "The hardware has automatically reconfigured the link to isolate the\nfailing lane, and successful retransmission of the data has occurred.\n"
1398 msgid "SUN4V-8002-PX.impact"
1399 msgstr "The system's capacity to correct transmission errors between the memory\nDIMM and its memory controller has been reduced.\n"
1400 msgid "SUN4V-8002-PX.action"
1401 msgstr "At your earliest convenience, schedule a repair procedure to replace the\naffected resource(s), the identity of which can be determined using\n'fmadm faulty'.\n"
1403 # code: SUN4V-8002-Q2
1404 # keys: fault.memory.memlink-uc
1406 msgid "SUN4V-8002-Q2.type"
1408 msgid "SUN4V-8002-Q2.severity"
1410 msgid "SUN4V-8002-Q2.description"
1411 msgstr "A problem was detected in the interconnect between a memory buffer\nand its memory controller.\n Refer to %s for more information."
1412 msgid "SUN4V-8002-Q2.response"
1413 msgstr "The system crashed to prevent data corruption. Memory in the affected\npartition may have been deconfigured. (Consult system-specific\ndocumentation to find out how to determine if memory has been\ndeconfigured.)\n"
1414 msgid "SUN4V-8002-Q2.impact"
1415 msgstr "If memory has been deconfigured, system performance may be impacted. \n"
1416 msgid "SUN4V-8002-Q2.action"
1417 msgstr "Schedule a repair procedure to replace the appropriate part(s), the identity of which can be determined using 'fmadm faulty'.\n"
1419 # code: SUN4V-8002-RA
1420 # keys: defect.fw.generic-sparc.addr-oob
1422 msgid "SUN4V-8002-RA.type"
1424 msgid "SUN4V-8002-RA.severity"
1426 msgid "SUN4V-8002-RA.description"
1427 msgstr "An address-out-of-bounds error has occurred.\n Refer to %s for more information."
1428 msgid "SUN4V-8002-RA.response"
1429 msgstr "No automated response.\n"
1430 msgid "SUN4V-8002-RA.impact"
1431 msgstr "The system may have taken a fatal reset.\n"
1432 msgid "SUN4V-8002-RA.action"
1433 msgstr "Call your service provider to determine if your system requires a firmware upgrade.\n"
1435 # code: SUN4V-8002-SP
1436 # keys: defect.fw.generic-sparc.erpt-gen
1438 msgid "SUN4V-8002-SP.type"
1440 msgid "SUN4V-8002-SP.severity"
1442 msgid "SUN4V-8002-SP.description"
1443 msgstr "The error report generator has received input data that is inconsistent or\nimproperly formatted.\n Refer to %s for more information."
1444 msgid "SUN4V-8002-SP.response"
1445 msgstr "No automated response.\n"
1446 msgid "SUN4V-8002-SP.impact"
1447 msgstr "This error does not affect system operation. The error which\ncould not be reported may have more serious impact which cannot be determined.\n"
1448 msgid "SUN4V-8002-SP.action"
1449 msgstr "Call your service provider to determine if your system requires a firmware\nupgrade. Please retain the error log file.\n"
1451 # code: SUN4V-8002-T5
1452 # keys: fault.cpu.generic-sparc.bootbus
1454 msgid "SUN4V-8002-T5.type"
1456 msgid "SUN4V-8002-T5.severity"
1458 msgid "SUN4V-8002-T5.description"
1459 msgstr "A system boot bus error has occurred.\n Refer to %s for more information."
1460 msgid "SUN4V-8002-T5.response"
1461 msgstr "No automated response.\n"
1462 msgid "SUN4V-8002-T5.impact"
1463 msgstr "The system's integrity is seriously compromised. Processor chip(s)\nmay be unavailable.\n"
1464 msgid "SUN4V-8002-T5.action"
1465 msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using 'fmadm faulty'.\n"
1467 # code: SUN4V-8002-US
1468 # keys: fault.sp.failed
1470 msgid "SUN4V-8002-US.type"
1472 msgid "SUN4V-8002-US.severity"
1474 msgid "SUN4V-8002-US.description"
1475 msgstr "The Service Processor failed.\n Refer to %s for more information."
1476 msgid "SUN4V-8002-US.response"
1477 msgstr "No automated response.\n"
1478 msgid "SUN4V-8002-US.impact"
1479 msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n"
1480 msgid "SUN4V-8002-US.action"
1481 msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n"