8322 nl: misleading-indentation
[unleashed/tickless.git] / usr / src / cmd / picl / plugins / sun4u / snowbird / conf / SUNW,Netra-CP2300.conf
blob8970f5f94c2516a5fc5277507ff3240a06a004e4
2 # CDDL HEADER START
4 # The contents of this file are subject to the terms of the
5 # Common Development and Distribution License, Version 1.0 only
6 # (the "License").  You may not use this file except in compliance
7 # with the License.
9 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
10 # or http://www.opensolaris.org/os/licensing.
11 # See the License for the specific language governing permissions
12 # and limitations under the License.
14 # When distributing Covered Code, include this CDDL HEADER in each
15 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
16 # If applicable, add the following below this CDDL HEADER, with the
17 # fields enclosed by brackets "[]" replaced with your own identifying
18 # information: Portions Copyright [yyyy] [name of copyright owner]
20 # CDDL HEADER END
23 # Copyright 2004 Sun Microsystems, Inc.  All rights reserved.
24 # Use is subject to license terms.
26 #pragma ident   "%Z%%M% %I%     %E% SMI"
27 VERSION 1.0
29 NODE CPU location
30         PROP State string r 0 "connected"
31         PROP SlotType string r 0 "pci"
32         PROP Label string r 0 "CPU"
33         PROP bus-addr string r 0 "1,1"
34         PROP devfs-path string r 0 "/pci@1f,0"
35         PROP PdevProbePath string r 0 "/pci@1f,0"
36         NODE CPU fru
37                 PROP FRUType string r 0 "bridge/fhs"
38                 PROP State string r 0 "configured"
39                 PROP Condition string r 0 "unknown"
40                 PROP AdminLock string rw 0 "disabled"
41                 NODE PMC-1 location
42                         PROP SlotType string r 0 "pci"
43                         PROP Label string r 0 "PMC-A"
44                         PROP bus-addr string r 0 "0x1"
45                         PROP GeoAddr uint r 1 1
46                         PROP devfs-path string r 0 "/pci@1f,0/pci@1"
47                 ENDNODE
48                 NODE PMC-2 location
49                         PROP SlotType string r 0 "pci"
50                         PROP Label string r 0 "PMC-B"
51                         PROP bus-addr string r 0 "0x2"
52                         PROP GeoAddr uint r 1 2
53                         PROP devfs-path string r 0 "/pci@1f,0/pci@1"
54                 ENDNODE
55                 NODE su0 port
56                         PROP Label string r 0 "COM"
57                         PROP bus-addr string r 0 "0,3f8"
58                         PROP GeoAddr uint r 1 1
59                         PROP PortType string r 0 "serial"
60                         PROP devfs-path string r 0 "/pci@1f,0/pci@1,1/isa@7"
61                 ENDNODE
62                 NODE dmfe0 port
63                         PROP Label string r 0 "ETHERNET A"
64                         PROP bus-addr string r 0 "1"
65                         PROP GeoAddr uint r 1 1
66                         PROP PortType string r 0 "network"
67                         PROP devfs-path string r 0 "/pci@1f,0/pci@1,1"
68                 ENDNODE
70                 NODE dmfe1 port
71                         PROP Label string r 0 "ETHERNET B"
72                         PROP bus-addr string r 0 "2"
73                         PROP GeoAddr uint r 1 2
74                         PROP PortType string r 0 "network"
75                         PROP devfs-path string r 0 "/pci@1f,0/pci@1,1"
76                 ENDNODE
77         ENDNODE
78 ENDNODE
79 NODE RTM location
80         PROP Label string r 0 "RTM"
81         PROP State string r 0 "empty"
82         PROP SlotType string r 0 "rtm"
83 ENDNODE