2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
6 # The contents of this file are subject to the terms of the
7 # Common Development and Distribution License (the "License").
8 # You may not use this file except in compliance with the License.
10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11 # or http://www.opensolaris.org/os/licensing.
12 # See the License for the specific language governing permissions
13 # and limitations under the License.
15 # When distributing Covered Code, include this CDDL HEADER in each
16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17 # If applicable, add the following below this CDDL HEADER, with the
18 # fields enclosed by brackets "[]" replaced with your own identifying
19 # information: Portions Copyright [yyyy] [name of copyright owner]
24 # DO NOT EDIT -- this file is generated by the Event Registry.
27 # General-purpose messages
29 msgid "syslog-msgs-message-template"
30 msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
32 # Fault-related messages
37 # keys: defect.sunos.fmd.nosub
39 msgid "FMD-8000-0W.type"
41 msgid "FMD-8000-0W.severity"
43 msgid "FMD-8000-0W.description"
44 msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information."
45 msgid "FMD-8000-0W.response"
46 msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
47 msgid "FMD-8000-0W.impact"
48 msgstr "Automated diagnosis and response for these events will not occur."
49 msgid "FMD-8000-0W.action"
50 msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
53 # keys: defect.sunos.fmd.nodiagcode
55 msgid "FMD-8000-11.type"
57 msgid "FMD-8000-11.severity"
59 msgid "FMD-8000-11.description"
60 msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information."
61 msgid "FMD-8000-11.response"
62 msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team."
63 msgid "FMD-8000-11.impact"
64 msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
65 msgid "FMD-8000-11.action"
66 msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Ensure that fault management software is installed properly."
69 # keys: defect.sunos.fmd.module
71 msgid "FMD-8000-2K.type"
73 msgid "FMD-8000-2K.severity"
75 msgid "FMD-8000-2K.description"
76 msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information."
77 msgid "FMD-8000-2K.response"
78 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis."
79 msgid "FMD-8000-2K.impact"
80 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
81 msgid "FMD-8000-2K.action"
82 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module."
85 # keys: defect.sunos.fmd.config
87 msgid "FMD-8000-3F.type"
89 msgid "FMD-8000-3F.severity"
91 msgid "FMD-8000-3F.description"
92 msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information."
93 msgid "FMD-8000-3F.response"
94 msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis."
95 msgid "FMD-8000-3F.impact"
96 msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
97 msgid "FMD-8000-3F.action"
98 msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration."
101 # keys: list.repaired
103 msgid "FMD-8000-4M.type"
105 msgid "FMD-8000-4M.severity"
107 msgid "FMD-8000-4M.description"
108 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information."
109 msgid "FMD-8000-4M.response"
110 msgstr "Some system components offlined because of the original fault may have been brought back online."
111 msgid "FMD-8000-4M.impact"
112 msgstr "Performance degradation of the system due to the original fault may have been recovered."
113 msgid "FMD-8000-4M.action"
114 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
119 msgid "FMD-8000-58.type"
121 msgid "FMD-8000-58.severity"
123 msgid "FMD-8000-58.description"
124 msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information."
125 msgid "FMD-8000-58.response"
126 msgstr "Some system components offlined because of the original fault may have been brought back online."
127 msgid "FMD-8000-58.impact"
128 msgstr "Performance degradation of the system due to the original fault may have been recovered."
129 msgid "FMD-8000-58.action"
130 msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
133 # keys: list.resolved
135 msgid "FMD-8000-6U.type"
137 msgid "FMD-8000-6U.severity"
139 msgid "FMD-8000-6U.description"
140 msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information."
141 msgid "FMD-8000-6U.response"
142 msgstr "All system components offlined because of the original fault have been brought back online."
143 msgid "FMD-8000-6U.impact"
144 msgstr "Performance degradation of the system due to the original fault has been recovered."
145 msgid "FMD-8000-6U.action"
146 msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."