2 # Copyright 2007 Sun Microsystems, Inc. All rights reserved.
3 # Use is subject to license terms.
7 # The contents of this file are subject to the terms of the
8 # Common Development and Distribution License (the "License").
9 # You may not use this file except in compliance with the License.
11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 # or http://www.opensolaris.org/os/licensing.
13 # See the License for the specific language governing permissions
14 # and limitations under the License.
16 # When distributing Covered Code, include this CDDL HEADER in each
17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 # If applicable, add the following below this CDDL HEADER, with the
19 # fields enclosed by brackets "[]" replaced with your own identifying
20 # information: Portions Copyright [yyyy] [name of copyright owner]
24 # DO NOT EDIT -- this file is generated by the Event Registry.
28 # keys: fault.chassis.SPARC-Enterprise.if.fe-asic-clk
30 msgid "SCF-8000-1D.type"
32 msgid "SCF-8000-1D.severity"
34 msgid "SCF-8000-1D.description"
35 msgstr "A fatal clock distribution error was detected by an ASIC or a CPU chip.\n Refer to %s for more information."
36 msgid "SCF-8000-1D.response"
37 msgstr "An attempt will be made to deconfigure the faulty components after one or more domains are reset.\n"
38 msgid "SCF-8000-1D.impact"
39 msgstr "One or more domains will be reset. Please consult the detail section of the knowledge article for \nadditional information.\n"
40 msgid "SCF-8000-1D.action"
41 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
44 # keys: fault.chassis.SPARC-Enterprise.if.fe-clk-cable
46 msgid "SCF-8000-2Y.type"
48 msgid "SCF-8000-2Y.severity"
50 msgid "SCF-8000-2Y.description"
51 msgstr "A Clock chip has detected a lack of connectivity between the base cabinet and the expansion cabinet.\n Refer to %s for more information."
52 msgid "SCF-8000-2Y.response"
53 msgstr "The entire platform is reset and the active Clock Units are deconfigured during recovery.\n"
54 msgid "SCF-8000-2Y.impact"
55 msgstr "The entire platform is reset and the active Clock Units are deconfigured during recovery.\n"
56 msgid "SCF-8000-2Y.action"
57 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
60 # keys: fault.chassis.SPARC-Enterprise.asic.clk.fe
62 msgid "SCF-8000-33.type"
64 msgid "SCF-8000-33.severity"
66 msgid "SCF-8000-33.description"
67 msgstr "A fatal error was detected within a Clock chip.\n Refer to %s for more information."
68 msgid "SCF-8000-33.response"
69 msgstr "The platform will be reset. If there is redundant clock capability, an attempt will be made to deconfigure \nthe active Clock Unit from service. \n"
70 msgid "SCF-8000-33.impact"
71 msgstr "If the platform lacks redundant clock capability, the platform will be powered down and will not\npower up. If the platform has redundant clock capability, the platform will be reset and the\nfaulty Clock Unit will be deconfigured during recovery.\n"
72 msgid "SCF-8000-33.action"
73 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
76 # keys: fault.chassis.SPARC-Enterprise.asic.clk.test
78 msgid "SCF-8000-4S.type"
80 msgid "SCF-8000-4S.severity"
82 msgid "SCF-8000-4S.description"
83 msgstr "Fault was detected during poweron self-test, either within a Clock chip with within one of the external\ninterfaces of a Clock chip.\n Refer to %s for more information."
84 msgid "SCF-8000-4S.response"
85 msgstr "An attempt will be made to remove the affected components from service. Please consult the detail \nsection of the knowledge article for additional information.\n"
86 msgid "SCF-8000-4S.impact"
87 msgstr "The entire platform is reset. If the platform lacks redundant clock capability, the platform will be \npowered down and will not power up. If the platform has redundant clock capability, the platform will be \nreset and the faulty Clock Unit will be deconfigured during recovery.\n"
88 msgid "SCF-8000-4S.action"
89 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
92 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.fe
94 msgid "SCF-8000-CJ.type"
96 msgid "SCF-8000-CJ.severity"
98 msgid "SCF-8000-CJ.description"
99 msgstr "An internal fatal error within a CPU chip was detected.\n Refer to %s for more information."
100 msgid "SCF-8000-CJ.response"
101 msgstr "The domain using this CPU will be reset and the CPU chip will be deconfigured.\n"
102 msgid "SCF-8000-CJ.impact"
103 msgstr "The CPU chip will be deconfigured after the domain is reset.\n"
104 msgid "SCF-8000-CJ.action"
105 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
108 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.fe
110 msgid "SCF-8000-DC.type"
112 msgid "SCF-8000-DC.severity"
114 msgid "SCF-8000-DC.description"
115 msgstr "An internal fatal error within a core on a CPU chip was detected.\n Refer to %s for more information."
116 msgid "SCF-8000-DC.response"
117 msgstr "The domain using this CPU will be reset and the core will be deconfigured.\n"
118 msgid "SCF-8000-DC.impact"
119 msgstr "The domain using this CPU chip is reset.\n"
120 msgid "SCF-8000-DC.action"
121 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
124 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.strand.fe
126 msgid "SCF-8000-EQ.type"
128 msgid "SCF-8000-EQ.severity"
130 msgid "SCF-8000-EQ.description"
131 msgstr "An internal fatal error within a strand on a CPU chip was detected.\n Refer to %s for more information."
132 msgid "SCF-8000-EQ.response"
133 msgstr "The domain using this CPU will be reset and the strand will be deconfigured.\n"
134 msgid "SCF-8000-EQ.impact"
135 msgstr "The domain using this CPU chip is reset.\n"
136 msgid "SCF-8000-EQ.action"
137 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
140 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se
142 msgid "SCF-8000-F4.type"
144 msgid "SCF-8000-F4.severity"
146 msgid "SCF-8000-F4.description"
147 msgstr "An internal non-fatal uncorrectable error within a CPU chip has been detected.\n Refer to %s for more information."
148 msgid "SCF-8000-F4.response"
149 msgstr "The CPU chip will be deconfigured after the platform is power cycled or after the domain reboots \nor after a Dynamic Reconfiguration operation is performed.\n"
150 msgid "SCF-8000-F4.impact"
151 msgstr "The non-fatal uncorrectable error may cause domain to panic. The CPU chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
152 msgid "SCF-8000-F4.action"
153 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
156 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.se
158 msgid "SCF-8000-GR.type"
160 msgid "SCF-8000-GR.severity"
162 msgid "SCF-8000-GR.description"
163 msgstr "A non-fatal uncorrectable error associated with a core on a CPU chip has been detected.\n Refer to %s for more information."
164 msgid "SCF-8000-GR.response"
165 msgstr "The domain software will attempt to offline the core on the CPU chip.\n"
166 msgid "SCF-8000-GR.impact"
167 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. If the domain\ndoes not panic, the domain software will attempt to offline the core on the CPU chip.\nThe core of the CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
168 msgid "SCF-8000-GR.action"
169 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
172 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.se-offlinereq
174 msgid "SCF-8000-H3.type"
176 msgid "SCF-8000-H3.severity"
178 msgid "SCF-8000-H3.description"
179 msgstr "When a non-fatal uncorrectable error occurs on a core on a CPU chip, domain software attempts to\noffline the core. This fault occurs when the number of offline attempts has exceeded an\nacceptable threshold.\n Refer to %s for more information."
180 msgid "SCF-8000-H3.response"
181 msgstr "Future non-fatal uncorrectable errors for this core on a CPU chip will not be recorded on the XSCF.\n"
182 msgid "SCF-8000-H3.impact"
183 msgstr "The uncorrectable error trap may cause the domain to panic.\n"
184 msgid "SCF-8000-H3.action"
185 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
188 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.strand.se
190 msgid "SCF-8000-JY.type"
192 msgid "SCF-8000-JY.severity"
194 msgid "SCF-8000-JY.description"
195 msgstr "A non-fatal uncorrectable error has been detected on a strand on a CPU chip.\n Refer to %s for more information."
196 msgid "SCF-8000-JY.response"
197 msgstr "The strand on the CPU chip is deconfigured.\n"
198 msgid "SCF-8000-JY.impact"
199 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic.\n"
200 msgid "SCF-8000-JY.action"
201 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
204 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.ce
206 msgid "SCF-8000-KD.type"
208 msgid "SCF-8000-KD.severity"
210 msgid "SCF-8000-KD.description"
211 msgstr "The number of correctable errors associated with a CPU chip has exceeded an acceptable threshold.\n Refer to %s for more information."
212 msgid "SCF-8000-KD.response"
213 msgstr "The CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
214 msgid "SCF-8000-KD.impact"
215 msgstr "No immediate impact. The CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
216 msgid "SCF-8000-KD.action"
217 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
220 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.ce
222 msgid "SCF-8000-LH.type"
224 msgid "SCF-8000-LH.severity"
226 msgid "SCF-8000-LH.description"
227 msgstr "The number of correctable errors associated with a core on a CPU chip have exceeded an acceptable threshold.\n Refer to %s for more information."
228 msgid "SCF-8000-LH.response"
229 msgstr "A request is sent to the domain software to attempt to offline the core on the CPU chip.\nThe core of the CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
230 msgid "SCF-8000-LH.impact"
231 msgstr "No immediate impact.\n"
232 msgid "SCF-8000-LH.action"
233 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
236 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.ce-offlinereq
238 msgid "SCF-8000-MA.type"
240 msgid "SCF-8000-MA.severity"
242 msgid "SCF-8000-MA.description"
243 msgstr "The number of correctable errors on a core on a CPU chip has exceeded an acceptable threshold. \nThis fault occurs when the number of offline attempts has exceeded an acceptable threshold.\n Refer to %s for more information."
244 msgid "SCF-8000-MA.response"
245 msgstr "Future correctable errors for this core on a CPU chip will not be recorded on the XSCF.\n"
246 msgid "SCF-8000-MA.impact"
247 msgstr "No immediate impact.\n"
248 msgid "SCF-8000-MA.action"
249 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
252 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.way.ce
254 msgid "SCF-8000-NP.type"
256 msgid "SCF-8000-NP.severity"
258 msgid "SCF-8000-NP.description"
259 msgstr "The number of correctable errors within a way of a CPU chip's L2 cache has exceeded an acceptable threshold.\n Refer to %s for more information."
260 msgid "SCF-8000-NP.response"
261 msgstr "The way of the CPU chip's cache is deconfigured. The performance of the CPU chip is reduced.\n"
262 msgid "SCF-8000-NP.impact"
263 msgstr "There is a performance loss for the CPU chip.\n"
264 msgid "SCF-8000-NP.action"
265 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
268 # keys: upset.chassis.SPARC-Enterprise.cpu.SPARC64-VI.fe
270 msgid "SCF-8000-P5.type"
272 msgid "SCF-8000-P5.severity"
274 msgid "SCF-8000-P5.description"
275 msgstr "A hard-to-diagnose problem was detected by the CPU chip.\n Refer to %s for more information."
276 msgid "SCF-8000-P5.response"
277 msgstr "Nothing is deconfigured.\n"
278 msgid "SCF-8000-P5.impact"
279 msgstr "The domain may drop to the OpenBoot PROM 'OK' prompt.\n"
280 msgid "SCF-8000-P5.action"
281 msgstr "The platform administrator should check to see if any other hardware failure has occurred on the platform.\nIf the problem occurs while running OpenBoot PROM, then the platform administrator should check to make sure that \nthe OpenBoot PROM environment variables have not been set incorrectly. If neither of these courses of action \nprovide a resolution, then the platform administrator should schedule a service action.\nPlease consult the detail section of the knowledge article for additional information.\n"
284 # keys: upset.chassis.SPARC-Enterprise.cpu.SPARC64-VI.fe-unexpected-trap
286 msgid "SCF-8000-QS.type"
288 msgid "SCF-8000-QS.severity"
290 msgid "SCF-8000-QS.description"
291 msgstr "An unexpected trap with some unknown cause was detected by a CPU chip during POST.\n Refer to %s for more information."
292 msgid "SCF-8000-QS.response"
293 msgstr "Nothing is deconfigured.\n"
294 msgid "SCF-8000-QS.impact"
295 msgstr "The domain is reset.\n"
296 msgid "SCF-8000-QS.action"
297 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
300 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se-tmo
302 msgid "SCF-8000-RJ.type"
304 msgid "SCF-8000-RJ.severity"
306 msgid "SCF-8000-RJ.description"
307 msgstr "An internal non-fatal uncorrectable error has been detected within the CPU chip.\n Refer to %s for more information."
308 msgid "SCF-8000-RJ.response"
309 msgstr "Nothing is deconfigured.\n"
310 msgid "SCF-8000-RJ.impact"
311 msgstr "The non-fatal uncorrectable error may cause the domain to panic.\n"
312 msgid "SCF-8000-RJ.action"
313 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
316 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se-uncertain
318 msgid "SCF-8000-SE.type"
320 msgid "SCF-8000-SE.severity"
322 msgid "SCF-8000-SE.description"
323 msgstr "An internal non-fatal uncorrectable error has been detected within the CPU chip.\n Refer to %s for more information."
324 msgid "SCF-8000-SE.response"
325 msgstr "Nothing is deconfigured.\n"
326 msgid "SCF-8000-SE.impact"
327 msgstr "The non-fatal uncorrectable error may cause the domain to panic.\n"
328 msgid "SCF-8000-SE.action"
329 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
332 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.ce-warn
334 msgid "SCF-8000-TX.type"
336 msgid "SCF-8000-TX.severity"
338 msgid "SCF-8000-TX.description"
339 msgstr "The number of correctable errors associated with a CPU chip has exceeded an acceptable threshold.\n Refer to %s for more information."
340 msgid "SCF-8000-TX.response"
341 msgstr "Nothing is deconfigured.\n"
342 msgid "SCF-8000-TX.impact"
343 msgstr "No immediate impact.\n"
344 msgid "SCF-8000-TX.action"
345 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
348 # keys: fault.chassis.SPARC-Enterprise.memory.fe
350 msgid "SCF-8000-YC.type"
352 msgid "SCF-8000-YC.severity"
354 msgid "SCF-8000-YC.description"
355 msgstr "A fatal error in a DIMM was detected by POST.\n Refer to %s for more information."
356 msgid "SCF-8000-YC.response"
357 msgstr "The memory associated with the memory bank that contains this\nDIMM is deconfigured.\n"
358 msgid "SCF-8000-YC.impact"
359 msgstr "POST is restarted after the memory associated with the memory bank that contains\nthis DIMM has been deconfigured.\n"
360 msgid "SCF-8000-YC.action"
361 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
364 # keys: fault.chassis.SPARC-Enterprise.memory.block.ue
366 msgid "SCF-8001-0Q.type"
368 msgid "SCF-8001-0Q.severity"
370 msgid "SCF-8001-0Q.description"
371 msgstr "An uncorrectable memory error (UE) has been detected.\n Refer to %s for more information."
372 msgid "SCF-8001-0Q.response"
373 msgstr "The 64MB of memory containing the memory that caused the UE will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed.\n"
374 msgid "SCF-8001-0Q.impact"
375 msgstr "The domain will receive an uncorrectable error trap which may cause the domain to panic. \n"
376 msgid "SCF-8001-0Q.action"
377 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
380 # keys: fault.chassis.SPARC-Enterprise.memory.block.mirror.ue
382 msgid "SCF-8001-1C.type"
384 msgid "SCF-8001-1C.severity"
386 msgid "SCF-8001-1C.description"
387 msgstr "A data compare error has been detected within a MAC chip when memory is in mirror mode.\n Refer to %s for more information."
388 msgid "SCF-8001-1C.response"
389 msgstr "The memory associated with the MAC chip will be deconfigured after the platform is power cycled \nor after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
390 msgid "SCF-8001-1C.impact"
391 msgstr "The domain will receive an uncorrectable error trap which may cause the domain to panic. \n"
392 msgid "SCF-8001-1C.action"
393 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
396 # keys: fault.chassis.SPARC-Enterprise.memory.block.pce
398 msgid "SCF-8001-2R.type"
400 msgid "SCF-8001-2R.severity"
402 msgid "SCF-8001-2R.description"
403 msgstr "A permanent correctable memory error (PCE) has been detected.\n Refer to %s for more information."
404 msgid "SCF-8001-2R.response"
405 msgstr "The 64MB chunk of memory that contains the permanent correctable error will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
406 msgid "SCF-8001-2R.impact"
407 msgstr "Minimal impact.\n"
408 msgid "SCF-8001-2R.action"
409 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
412 # keys: fault.chassis.SPARC-Enterprise.memory.dimm.pce
414 msgid "SCF-8001-34.type"
416 msgid "SCF-8001-34.severity"
418 msgid "SCF-8001-34.description"
419 msgstr "The number of permanent correctable errors (PCE's) on single DIMM exceeds an\nacceptable threshold.\n Refer to %s for more information."
420 msgid "SCF-8001-34.response"
421 msgstr "No immediate action is taken and nothing is deconfigured.\n"
422 msgid "SCF-8001-34.impact"
423 msgstr "Minimal impact to system.\n"
424 msgid "SCF-8001-34.action"
425 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
428 # keys: fault.chassis.SPARC-Enterprise.memory.bank.err
430 msgid "SCF-8001-4X.type"
432 msgid "SCF-8001-4X.severity"
434 msgid "SCF-8001-4X.description"
435 msgstr "The number of uncorrectable and correctable errors on single DIMM exceeds an\nacceptable threshold. This fault is detected while running POST.\n Refer to %s for more information."
436 msgid "SCF-8001-4X.response"
437 msgstr "The memory associated with the memory bank containing the errors is deconfigured.\n"
438 msgid "SCF-8001-4X.impact"
439 msgstr "POST is restarted after the memory associated with the memory bank has been deconfigured.\n"
440 msgid "SCF-8001-4X.action"
441 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
444 # keys: fault.chassis.SPARC-Enterprise.asic.flp.fe
446 msgid "SCF-8001-9S.type"
448 msgid "SCF-8001-9S.severity"
450 msgid "SCF-8001-9S.description"
451 msgstr "A fatal error has occurred within a FLP chip.\n Refer to %s for more information."
452 msgid "SCF-8001-9S.response"
453 msgstr "A single domain will be reset and the IO Channel associated with the\nFLP chip will be deconfigured during recovery.\n"
454 msgid "SCF-8001-9S.impact"
455 msgstr "Domain will be reset.\n"
456 msgid "SCF-8001-9S.action"
457 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
460 # keys: fault.chassis.SPARC-Enterprise.asic.flp.ce
462 msgid "SCF-8001-AA.type"
464 msgid "SCF-8001-AA.severity"
466 msgid "SCF-8001-AA.description"
467 msgstr "The number of correctable errors associated with a FLP chip has exceeded an\nacceptable threshold.\n Refer to %s for more information."
468 msgid "SCF-8001-AA.response"
469 msgstr "The IO Channel associated with the FLP chip will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
470 msgid "SCF-8001-AA.impact"
471 msgstr "No immediate impact. The IO Channel associated with the FLP chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is \nperformed.\n"
472 msgid "SCF-8001-AA.action"
473 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
476 # keys: upset.chassis.SPARC-Enterprise.io.disk.boot
478 msgid "SCF-8001-KC.type"
480 msgid "SCF-8001-KC.severity"
482 msgid "SCF-8001-KC.description"
483 msgstr "Failure to boot illumos on a domain via an internal disk drive on the SAS controller.\n Refer to %s for more information."
484 msgid "SCF-8001-KC.response"
485 msgstr "Nothing is deconfigured.\n"
486 msgid "SCF-8001-KC.impact"
487 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
488 msgid "SCF-8001-KC.action"
489 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
492 # keys: fault.chassis.SPARC-Enterprise.if.fe-ioc-flp
494 msgid "SCF-8001-LQ.type"
496 msgid "SCF-8001-LQ.severity"
498 msgid "SCF-8001-LQ.description"
499 msgstr "A fatal error occurred on the interface between an IOC chip and a FLP chip.\n Refer to %s for more information."
500 msgid "SCF-8001-LQ.response"
501 msgstr "The IO Channel associated with the FLP chip will be deconfigured after the domain\nusing the IO Channel is reset.\n"
502 msgid "SCF-8001-LQ.impact"
503 msgstr "The domain using the IO Channel associated with the FLP chip is reset. The IO Channel will\ndeconfigured after the domain is reset.\n"
504 msgid "SCF-8001-LQ.action"
505 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
508 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.fe
510 msgid "SCF-8001-ME.type"
512 msgid "SCF-8001-ME.severity"
514 msgid "SCF-8001-ME.description"
515 msgstr "A fatal error was detected within an IOC chip.\n Refer to %s for more information."
516 msgid "SCF-8001-ME.response"
517 msgstr "The IOC chip (two IO Channels) will be deconfigured after the domains (one or two domains) using\nthe IOC chip are reset.\n"
518 msgid "SCF-8001-ME.impact"
519 msgstr "The domains (one or two domains) using the IOC chip are reset. The IOC chip (two IO Channels) will be \ndeconfigured after the domains are reset.\n"
520 msgid "SCF-8001-ME.action"
521 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
524 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.fe-tmo-dma
526 msgid "SCF-8001-NJ.type"
528 msgid "SCF-8001-NJ.severity"
530 msgid "SCF-8001-NJ.description"
531 msgstr "A fatal DMA master timeout detected by an IOC chip.\n Refer to %s for more information."
532 msgid "SCF-8001-NJ.response"
533 msgstr "The domains (one or two domains) using the IOC chip are reset. No components are deconfigured.\n"
534 msgid "SCF-8001-NJ.impact"
535 msgstr "The domains (one or two domains) using the IOC chip are reset.\n"
536 msgid "SCF-8001-NJ.action"
537 msgstr "The precise cause of the fault cannot be isolated. Please schedule a repair action.\nPlease consult the detail section of the knowledge article for additional information.\n"
540 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.fe
542 msgid "SCF-8001-P2.type"
544 msgid "SCF-8001-P2.severity"
546 msgid "SCF-8001-P2.description"
547 msgstr "A fatal error was detected within an IOC chip. This fatal error affects only a single\nIO Channel.\n Refer to %s for more information."
548 msgid "SCF-8001-P2.response"
549 msgstr "The IO Channel will be deconfigured after the domain is reset.\n"
550 msgid "SCF-8001-P2.impact"
551 msgstr "The domain using the IO Channel is reset. The IO Channel will be deconfigured after\nthe domain is reset.\n"
552 msgid "SCF-8001-P2.action"
553 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information\n"
556 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.fe
558 msgid "SCF-8001-QX.type"
560 msgid "SCF-8001-QX.severity"
562 msgid "SCF-8001-QX.description"
563 msgstr "A fatal error was detected within an IOC chip. The fatal error affects only one leaf within\nan IO Channel (1/2 an IO Channel).\n Refer to %s for more information."
564 msgid "SCF-8001-QX.response"
565 msgstr "The IO Channel leaf (1/2 an IO Channel) will be deconfigured after the domain using the IO\nChannel is reset.\n"
566 msgid "SCF-8001-QX.impact"
567 msgstr "The domain using the IO Channel leaf is reset. The IO Channel leaf (1/2 an IO Channel) will be\ndeconfigured after the domain is reset.\n"
568 msgid "SCF-8001-QX.action"
569 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
572 # keys: fault.chassis.SPARC-Enterprise.io.pciex.card.fe
574 msgid "SCF-8001-RP.type"
576 msgid "SCF-8001-RP.severity"
578 msgid "SCF-8001-RP.description"
579 msgstr "A fatal error was detected on a PCI-Express card in a PCI slot.\n Refer to %s for more information."
580 msgid "SCF-8001-RP.response"
581 msgstr "The PCI-Express card is deconfigured.\n"
582 msgid "SCF-8001-RP.impact"
583 msgstr "The domain using the PCI slot is reset.\n"
584 msgid "SCF-8001-RP.action"
585 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
588 # keys: fault.chassis.SPARC-Enterprise.io.pci.card.fe
590 msgid "SCF-8001-SA.type"
592 msgid "SCF-8001-SA.severity"
594 msgid "SCF-8001-SA.description"
595 msgstr "A fatal error was detected on a PCI-X card in a PCI slot.\n Refer to %s for more information."
596 msgid "SCF-8001-SA.response"
597 msgstr "The PCI-X card is deconfigured.\n"
598 msgid "SCF-8001-SA.impact"
599 msgstr "The domain using the PCI slot is reset.\n"
600 msgid "SCF-8001-SA.action"
601 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
604 # keys: fault.chassis.SPARC-Enterprise.io.pciex.bridge.fe
606 msgid "SCF-8001-TS.type"
608 msgid "SCF-8001-TS.severity"
610 msgid "SCF-8001-TS.description"
611 msgstr "A fatal error was detected within a PCIe/PCI-X bridge chip.\n Refer to %s for more information."
612 msgid "SCF-8001-TS.response"
613 msgstr "All internal I/O behind the PCIe/PCI-X bridge chip is deconfigured (if the\nPCIe/PCI-X bridge chip is located on an IOU or IOUA) or all the PCI-X slots \nin an I/O Boat are deconfigured (if the PCIe/PCI-X bridge chip is located on\nan I/O Boat).\n"
614 msgid "SCF-8001-TS.impact"
615 msgstr "The domain using the PCIe/PCI-X bridge chip is reset.\n"
616 msgid "SCF-8001-TS.action"
617 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
620 # keys: fault.chassis.SPARC-Enterprise.io.pciex.switch.fe
622 msgid "SCF-8001-U5.type"
624 msgid "SCF-8001-U5.severity"
626 msgid "SCF-8001-U5.description"
627 msgstr "A fatal error was detected within a PCIe switch chip.\n Refer to %s for more information."
628 msgid "SCF-8001-U5.response"
629 msgstr "All internal I/O behind the PCIe switch chip is deconfigured (if the PCIe switch chip\nis located on an IOU) or all the PCI-Express slots or PCI-X slots in an I/O Boat are \ndeconfigured (if the PCIe switch chip is located on an I/O Boat).\n"
630 msgid "SCF-8001-U5.impact"
631 msgstr "The domain using the PCIe switch chip is reset.\n"
632 msgid "SCF-8001-U5.action"
633 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
636 # keys: fault.chassis.SPARC-Enterprise.io.pci.gbe.fe
638 msgid "SCF-8001-VY.type"
640 msgid "SCF-8001-VY.severity"
642 msgid "SCF-8001-VY.description"
643 msgstr "A fatal error was detected within a Gigabit Ethernet (GbE) controller.\n Refer to %s for more information."
644 msgid "SCF-8001-VY.response"
645 msgstr "The Gigabit Ethernet (GbE) controller is deconfigured.\n"
646 msgid "SCF-8001-VY.impact"
647 msgstr "The domain using the Gigabit Ethernet (GbE) controller is reset.\n"
648 msgid "SCF-8001-VY.action"
649 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
652 # keys: fault.chassis.SPARC-Enterprise.io.pci.sas.fe
654 msgid "SCF-8001-W3.type"
656 msgid "SCF-8001-W3.severity"
658 msgid "SCF-8001-W3.description"
659 msgstr "A fatal error was detected within a SAS (Serial Attached SCSI) controller.\n Refer to %s for more information."
660 msgid "SCF-8001-W3.response"
661 msgstr "The internal SAS devices behind the SAS controller (internal HDDs, internal DVD drives, internal\ntape drives) are deconfigured.\n"
662 msgid "SCF-8001-W3.impact"
663 msgstr "The domain using the SAS controller is reset.\n"
664 msgid "SCF-8001-W3.action"
665 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
668 # keys: fault.chassis.SPARC-Enterprise.if.se-ioc-flp
670 msgid "SCF-8001-XH.type"
672 msgid "SCF-8001-XH.severity"
674 msgid "SCF-8001-XH.description"
675 msgstr "A non-fatal uncorrectable error occurred on the interface between an IOC chip and a FLP chip.\n Refer to %s for more information."
676 msgid "SCF-8001-XH.response"
677 msgstr "The IO Channel corresponding to the FLP chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
678 msgid "SCF-8001-XH.impact"
679 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe IO Channel corresponding to the FLP chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
680 msgid "SCF-8001-XH.action"
681 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
684 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.se
686 msgid "SCF-8001-YD.type"
688 msgid "SCF-8001-YD.severity"
690 msgid "SCF-8001-YD.description"
691 msgstr "A non-fatal uncorrectable error was detected within an IOC chip. This error affects\na single IO Channel.\n Refer to %s for more information."
692 msgid "SCF-8001-YD.response"
693 msgstr "The IO Channel will be deconfigured after the platform is power cycled or after the domain reboots or \nafter a Dynamic Reconfiguration operation is performed.\n"
694 msgid "SCF-8001-YD.impact"
695 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. The IO Channel will be deconfigured \nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed.\n"
696 msgid "SCF-8001-YD.action"
697 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
700 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.se
702 msgid "SCF-8002-0X.type"
704 msgid "SCF-8002-0X.severity"
706 msgid "SCF-8002-0X.description"
707 msgstr "Non-fatal uncorrectable error was detected within an IOC chip. This error affects\na single IO Channel leaf (1/2 an IO Channel).\n Refer to %s for more information."
708 msgid "SCF-8002-0X.response"
709 msgstr "The IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
710 msgid "SCF-8002-0X.impact"
711 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
712 msgid "SCF-8002-0X.action"
713 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
716 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.se-no-credit-pci
718 msgid "SCF-8002-12.type"
720 msgid "SCF-8002-12.severity"
722 msgid "SCF-8002-12.description"
723 msgstr "A non-fatal uncorrectable \"PCI-E card no-credit update\" error has been detected by an IOC chip.\n Refer to %s for more information."
724 msgid "SCF-8002-12.response"
725 msgstr "The IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
726 msgid "SCF-8002-12.impact"
727 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
728 msgid "SCF-8002-12.action"
729 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
732 # keys: fault.chassis.SPARC-Enterprise.io.pciex.card.se
734 msgid "SCF-8002-2J.type"
736 msgid "SCF-8002-2J.severity"
738 msgid "SCF-8002-2J.description"
739 msgstr "A non-fatal uncorrectable error occurred due to a PCI-Express card in a PCI-Express slot.\n Refer to %s for more information."
740 msgid "SCF-8002-2J.response"
741 msgstr "The PCI-Express slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
742 msgid "SCF-8002-2J.impact"
743 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe PCI-Express slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
744 msgid "SCF-8002-2J.action"
745 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
748 # keys: fault.chassis.SPARC-Enterprise.io.pci.card.se
750 msgid "SCF-8002-3E.type"
752 msgid "SCF-8002-3E.severity"
754 msgid "SCF-8002-3E.description"
755 msgstr "A non-fatal uncorrectable error occcurred due to a PCI-X card in a PCI slot.\n Refer to %s for more information."
756 msgid "SCF-8002-3E.response"
757 msgstr "The PCI-X slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
758 msgid "SCF-8002-3E.impact"
759 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe PCI-X slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
760 msgid "SCF-8002-3E.action"
761 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
764 # keys: fault.chassis.SPARC-Enterprise.io.pciex.bridge.se
766 msgid "SCF-8002-4Q.type"
768 msgid "SCF-8002-4Q.severity"
770 msgid "SCF-8002-4Q.description"
771 msgstr "A non-fatal uncorrectable error was detected within a PCIe/PCI-X bridge chip.\n Refer to %s for more information."
772 msgid "SCF-8002-4Q.response"
773 msgstr "All internal I/O behind the PCIe/PCI-X bridge chip is deconfigured (if the\nPCIe/PCI-X bridge chip is located on an IOU or IOUA) or all the PCI-X slots \nin an I/O Boat are deconfigured (if the PCIe/PCI-X bridge chip is located on\nan I/O Boat). The deconfiguration will take place after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
774 msgid "SCF-8002-4Q.impact"
775 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nAll internal I/O behind the PCIe/PCI-X bridge chip is deconfigured (if the\nPCIe/PCI-X bridge chip is located on an IOU or IOUA) or all the PCI-X slots \nin an I/O Boat are deconfigured (if the PCIe/PCI-X bridge chip is located on\nan I/O Boat). The deconfiguration will take place after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
776 msgid "SCF-8002-4Q.action"
777 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
780 # keys: fault.chassis.SPARC-Enterprise.io.pciex.switch.se
782 msgid "SCF-8002-5C.type"
784 msgid "SCF-8002-5C.severity"
786 msgid "SCF-8002-5C.description"
787 msgstr "A non-fatal uncorrectable error was detected within a PCIe switch chip.\n Refer to %s for more information."
788 msgid "SCF-8002-5C.response"
789 msgstr "All internal I/O behind the PCIe switch chip is deconfigured (if the PCIe switch chip\nis located on an IOU) or all the PCI-Express slots or PCI-X slots in an I/O Boat are \ndeconfigured (if the PCIe switch chip is located on an I/O Boat). The deconfiguration\nwill take place after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
790 msgid "SCF-8002-5C.impact"
791 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nAll internal I/O behind the PCIe switch chip is deconfigured (if the PCIe switch chip\nis located on an IOU) or all the PCI-Express slots or PCI-X slots in an I/O Boat are \ndeconfigured (if the PCIe switch chip is located on an I/O Boat). The deconfiguration\nwill take place after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
792 msgid "SCF-8002-5C.action"
793 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
796 # keys: fault.chassis.SPARC-Enterprise.if.ce-ioc-flp
798 msgid "SCF-8002-6R.type"
800 msgid "SCF-8002-6R.severity"
802 msgid "SCF-8002-6R.description"
803 msgstr "The number of correctable errors on the interface between an IOC chip and a FLP chip has exceeded \nan acceptable threshold.\n Refer to %s for more information."
804 msgid "SCF-8002-6R.response"
805 msgstr "The IO Channel that is associated with the FLP chip will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
806 msgid "SCF-8002-6R.impact"
807 msgstr "No immediate impact. The IO Channel that is associated with the FLP chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is \nperformed.\n"
808 msgid "SCF-8002-6R.action"
809 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
812 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.ce
814 msgid "SCF-8002-74.type"
816 msgid "SCF-8002-74.severity"
818 msgid "SCF-8002-74.description"
819 msgstr "The number of correctable errors within a IOC Chip has exceeded an acceptable threshold. This fault\naffects a single IO Channel.\n Refer to %s for more information."
820 msgid "SCF-8002-74.response"
821 msgstr "The IO Channel is deconfigured after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
822 msgid "SCF-8002-74.impact"
823 msgstr "No immediate impact. The IO Channel is deconfigured after the platform is power cycled or after the \ndomain reboots or after a Dynamic Reconfiguration operation is performed.\n"
824 msgid "SCF-8002-74.action"
825 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
828 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.ce
830 msgid "SCF-8002-8D.type"
832 msgid "SCF-8002-8D.severity"
834 msgid "SCF-8002-8D.description"
835 msgstr "The number of correctable errors within a IOC Chip has exceeded an acceptable threshold. This fault\naffects a single IO Channel leaf (1/2 an IO Channel).\n Refer to %s for more information."
836 msgid "SCF-8002-8D.response"
837 msgstr "The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is power cycled or after \nthe domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
838 msgid "SCF-8002-8D.impact"
839 msgstr "No immediate impact. The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is \npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
840 msgid "SCF-8002-8D.action"
841 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
844 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.boot
846 msgid "SCF-8002-9H.type"
848 msgid "SCF-8002-9H.severity"
850 msgid "SCF-8002-9H.description"
851 msgstr "Failure to boot illumos on a domain using a device on an IO Channel.\n Refer to %s for more information."
852 msgid "SCF-8002-9H.response"
853 msgstr "Nothing is deconfigured.\n"
854 msgid "SCF-8002-9H.impact"
855 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
856 msgid "SCF-8002-9H.action"
857 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
860 # keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.boot
862 msgid "SCF-8002-A3.type"
864 msgid "SCF-8002-A3.severity"
866 msgid "SCF-8002-A3.description"
867 msgstr "Failure to boot illumos on a domain using a device on IO Channel leaf (1/2 an IO Channel).\n Refer to %s for more information."
868 msgid "SCF-8002-A3.response"
869 msgstr "Nothing is deconfigured.\n"
870 msgid "SCF-8002-A3.impact"
871 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
872 msgid "SCF-8002-A3.action"
873 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
876 # keys: upset.chassis.SPARC-Enterprise.io.pci.gbe.boot
878 msgid "SCF-8002-CY.type"
880 msgid "SCF-8002-CY.severity"
882 msgid "SCF-8002-CY.description"
883 msgstr "Failure to boot illumos on a domain via GbE.\n Refer to %s for more information."
884 msgid "SCF-8002-CY.response"
885 msgstr "Nothing is deconfigured.\n"
886 msgid "SCF-8002-CY.impact"
887 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
888 msgid "SCF-8002-CY.action"
889 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
892 # keys: upset.chassis.SPARC-Enterprise.io.pci.card.boot
894 msgid "SCF-8002-D5.type"
896 msgid "SCF-8002-D5.severity"
898 msgid "SCF-8002-D5.description"
899 msgstr "Failure to boot illumos on a domain using a device in a PCI-X slot.\n Refer to %s for more information."
900 msgid "SCF-8002-D5.response"
901 msgstr "Nothing is deconfigured.\n"
902 msgid "SCF-8002-D5.impact"
903 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt\n"
904 msgid "SCF-8002-D5.action"
905 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
908 # keys: upset.chassis.SPARC-Enterprise.io.pciex.card.boot
910 msgid "SCF-8002-ES.type"
912 msgid "SCF-8002-ES.severity"
914 msgid "SCF-8002-ES.description"
915 msgstr "Failure to boot illumos on a domain using a device in a PCI-Express slot.\n Refer to %s for more information."
916 msgid "SCF-8002-ES.response"
917 msgstr "Nothing is deconfigured.\n"
918 msgid "SCF-8002-ES.impact"
919 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
920 msgid "SCF-8002-ES.action"
921 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
924 # keys: upset.chassis.SPARC-Enterprise.io.pciex.bridge.boot
926 msgid "SCF-8002-FA.type"
928 msgid "SCF-8002-FA.severity"
930 msgid "SCF-8002-FA.description"
931 msgstr "Failure to boot illumos on a domain using a device behind a PCI-Express/PCI-X \nbridge chip. This includes the PCI-X slot and internal I/O on an IOU (if the\nPCI-Express/PCI-X bridge is located on an IOU or IOUA) and the PCI-X slots of\nan I/O Boat (if the PCI-Express/PCI-X bridge is located on an I/O Boat).\n Refer to %s for more information."
932 msgid "SCF-8002-FA.response"
933 msgstr "Nothing is deconfigured.\n"
934 msgid "SCF-8002-FA.impact"
935 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
936 msgid "SCF-8002-FA.action"
937 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
940 # keys: upset.chassis.SPARC-Enterprise.io.pciex.switch.boot
942 msgid "SCF-8002-GP.type"
944 msgid "SCF-8002-GP.severity"
946 msgid "SCF-8002-GP.description"
947 msgstr "Failure to boot illumos on a domain using a device behind a PCI-Express switch chip.\nThis includes PCI-X slot and internal I/O devices (if the PCI-Express switch chip \nis located on an IOU), and the PCI-Express slots and PCI-X slots on an I/O Boat\n(if the PCI-Express switch chip is located on an I/O Boat).\n Refer to %s for more information."
948 msgid "SCF-8002-GP.response"
949 msgstr "Nothing is deconfigured.\n"
950 msgid "SCF-8002-GP.impact"
951 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
952 msgid "SCF-8002-GP.action"
953 msgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
956 # keys: upset.chassis.SPARC-Enterprise.io.pci.sas.boot
958 msgid "SCF-8002-HE.type"
960 msgid "SCF-8002-HE.severity"
962 msgid "SCF-8002-HE.description"
963 msgstr "Failure to boot illumos on a domain using an internal SAS (Serial Attached\nSCSI) device. This includes the internal hard drives and the internal DVD drives\nand the internal tape drives.\n Refer to %s for more information."
964 msgid "SCF-8002-HE.response"
965 msgstr "Nothing is deconfigured.\n"
966 msgid "SCF-8002-HE.impact"
967 msgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
968 msgid "SCF-8002-HE.action"
969 msgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
972 # keys: fault.chassis.jtag.device
974 msgid "SCF-8002-JJ.type"
976 msgid "SCF-8002-JJ.severity"
978 msgid "SCF-8002-JJ.description"
979 msgstr "JTAG read or write failure to a specific chip.\n Refer to %s for more information."
980 msgid "SCF-8002-JJ.response"
981 msgstr "The resources associated with the chip will be deconfigured. Please consult the detail section \nof the knowledge article for additional information.\n"
982 msgid "SCF-8002-JJ.impact"
983 msgstr "The platform may be reset or a domain may be reset. The platform may be unable to restart.\nPlease consult the detail section of the knowledge article for additional information.\n"
984 msgid "SCF-8002-JJ.action"
985 msgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
988 # keys: fault.chassis.jtag.device-internal
990 msgid "SCF-8002-K2.type"
992 msgid "SCF-8002-K2.severity"
994 msgid "SCF-8002-K2.description"
995 msgstr "JTAG access failure to a specific chip when attempting a reconfiguration operation.\nPlease consult the detail section of the knowledge article for additional information.\n Refer to %s for more information."
996 msgid "SCF-8002-K2.response"
997 msgstr "The resources associated with the chip will be deconfigured. Please consult the detail section of \nthe knowledge article for additional information.\n"
998 msgid "SCF-8002-K2.impact"
999 msgstr "The platform may be reset or a domain may be reset. The platform may become unbootable.\nIt is also possible that some other problem may occur. Please consult the detail section of the \nknowledge article for additional information.\n"
1000 msgid "SCF-8002-K2.action"
1001 msgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1004 # keys: fault.chassis.i2c.device
1006 msgid "SCF-8002-LX.type"
1008 msgid "SCF-8002-LX.severity"
1010 msgid "SCF-8002-LX.description"
1011 msgstr "I2C access failure to an I2C device.\n Refer to %s for more information."
1012 msgid "SCF-8002-LX.response"
1013 msgstr "The resources associated with the I2C device may deconfigured. The speed of all fans on the platform\nmay be raised. Please consult the detail section of the knowledge article for additional information.\n"
1014 msgid "SCF-8002-LX.impact"
1015 msgstr "It is possible that the platform will not be able to be be restarted. Please consult the detail section \nof the knowledge article for additional information.\n"
1016 msgid "SCF-8002-LX.action"
1017 msgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1020 # keys: fault.chassis.i2c.device-internal
1022 msgid "SCF-8002-M4.type"
1024 msgid "SCF-8002-M4.severity"
1026 msgid "SCF-8002-M4.description"
1027 msgstr "I2C access failure to a specific chip when attempting a reconfiguration operation.\nPlease consult the detail section of the knowledge article for additional information.\n Refer to %s for more information."
1028 msgid "SCF-8002-M4.response"
1029 msgstr "The resources associated with the chip will be deconfigured. Please consult the detail section of the \nknowledge article for additional information.\n"
1030 msgid "SCF-8002-M4.impact"
1031 msgstr "One or more domains may be reset. It is also possible that some other problem may occur. \nPlease consult the detail section of the knowledge article for additional information.\n"
1032 msgid "SCF-8002-M4.action"
1033 msgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1036 # keys: fault.chassis.SPARC-Enterprise.asic.mac.fe
1038 msgid "SCF-8002-UD.type"
1040 msgid "SCF-8002-UD.severity"
1042 msgid "SCF-8002-UD.description"
1043 msgstr "A fatal error was detected within a MAC chip.\n Refer to %s for more information."
1044 msgid "SCF-8002-UD.response"
1045 msgstr "Memory associated within the MAC chip will be deconfigured.\n"
1046 msgid "SCF-8002-UD.impact"
1047 msgstr "Platform may be reset or domains using the MAC chip will be reset.\n"
1048 msgid "SCF-8002-UD.action"
1049 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1052 # keys: fault.chassis.SPARC-Enterprise.asic.mac.bank.fe
1054 msgid "SCF-8002-VP.type"
1056 msgid "SCF-8002-VP.severity"
1058 msgid "SCF-8002-VP.description"
1059 msgstr "A fatal error was detected within the part of a MAC chip that controls a memory bank.\n Refer to %s for more information."
1060 msgid "SCF-8002-VP.response"
1061 msgstr "The bank of memory is deconfigured.\n"
1062 msgid "SCF-8002-VP.impact"
1063 msgstr "Domain using the memory bank will be reset.\n"
1064 msgid "SCF-8002-VP.action"
1065 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1068 # keys: fault.chassis.SPARC-Enterprise.asic.mac.se
1070 msgid "SCF-8002-WA.type"
1072 msgid "SCF-8002-WA.severity"
1074 msgid "SCF-8002-WA.description"
1075 msgstr "A non-fatal uncorrectable error was detected within a MAC chip.\n Refer to %s for more information."
1076 msgid "SCF-8002-WA.response"
1077 msgstr "Memory associated with the MAC chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1078 msgid "SCF-8002-WA.impact"
1079 msgstr "The domain may panic, the MAC memory patrol feature may stop working, or access to MAC registers from the\ndomain may fail.\n"
1080 msgid "SCF-8002-WA.action"
1081 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1084 # keys: fault.chassis.SPARC-Enterprise.asic.mac.bank.se
1086 msgid "SCF-8002-XS.type"
1088 msgid "SCF-8002-XS.severity"
1090 msgid "SCF-8002-XS.description"
1091 msgstr "A non-fatal uncorrectable error was detected within the part of a MAC chip that controls a memory bank.\n Refer to %s for more information."
1092 msgid "SCF-8002-XS.response"
1093 msgstr "Memory associated with this memory bank is deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1094 msgid "SCF-8002-XS.impact"
1095 msgstr "The domain will encounter an non-fatal uncorrectable error and the domain may panic.\n"
1096 msgid "SCF-8002-XS.action"
1097 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1100 # keys: fault.chassis.SPARC-Enterprise.asic.mac.ce
1102 msgid "SCF-8002-Y5.type"
1104 msgid "SCF-8002-Y5.severity"
1106 msgid "SCF-8002-Y5.description"
1107 msgstr "The number of correctable errors detected within a MAC chip has exceeded an\nacceptable threshold.\n Refer to %s for more information."
1108 msgid "SCF-8002-Y5.response"
1109 msgstr "Memory associated to the MAC will be deconfigured after the platform is power cycled or after \nthe domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1110 msgid "SCF-8002-Y5.impact"
1111 msgstr "No immediate impact. Memory associated to the MAC will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1112 msgid "SCF-8002-Y5.action"
1113 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1116 # keys: fault.chassis.SPARC-Enterprise.asic.mac.bank.ce
1118 msgid "SCF-8003-0S.type"
1120 msgid "SCF-8003-0S.severity"
1122 msgid "SCF-8003-0S.description"
1123 msgstr "The number of correctable errors detected within the part of a MAC chip that controls a memory\nbank has exceeded an acceptable threshold.\n Refer to %s for more information."
1124 msgid "SCF-8003-0S.response"
1125 msgstr "Memory associated with the memory bank will be deconfigured after the platform is power cycled or after \nthe domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1126 msgid "SCF-8003-0S.impact"
1127 msgstr "No immediate impact. Memory associated with the memory bank will be deconfigured after the platform \nis power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1128 msgid "SCF-8003-0S.action"
1129 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1132 # keys: fault.chassis.SPARC-Enterprise.madm.io.se
1134 msgid "SCF-8003-5D.type"
1136 msgid "SCF-8003-5D.severity"
1138 msgid "SCF-8003-5D.description"
1139 msgstr "Machine Administration Sofware (MADM) on the domain detected a serious I/O problem.\n Refer to %s for more information."
1140 msgid "SCF-8003-5D.response"
1141 msgstr "No immediate action is taken and nothing is deconfigured.\n"
1142 msgid "SCF-8003-5D.impact"
1143 msgstr "Problem with an I/O device.\n"
1144 msgid "SCF-8003-5D.action"
1145 msgstr "The platform administrator should use the output of the showlogs command to determine\nif a service action is necessary. Please consult the detail section of the knowledge\narticle for additional information.\n"
1148 # keys: fault.chassis.SPARC-Enterprise.madm.io.fe
1150 msgid "SCF-8003-6Y.type"
1152 msgid "SCF-8003-6Y.severity"
1154 msgid "SCF-8003-6Y.description"
1155 msgstr "Machine Administration Sofware (MADM) on the domain detected a fatal I/O problem.\n Refer to %s for more information."
1156 msgid "SCF-8003-6Y.response"
1157 msgstr "Nothing is deconfigured on the XSCF, but the domain will deconfigure the I/O device.\n"
1158 msgid "SCF-8003-6Y.impact"
1159 msgstr "Problem with an I/O device.\n"
1160 msgid "SCF-8003-6Y.action"
1161 msgstr "The platform administrator should use the output of the showlogs command to determine\nif a service action is necessary. Please consult the detail section of the knowledge\narticle for additional information.\n"
1164 # keys: fault.chassis.SPARC-Enterprise.if.fe-mbc-sc
1166 msgid "SCF-8003-GJ.type"
1168 msgid "SCF-8003-GJ.severity"
1170 msgid "SCF-8003-GJ.description"
1171 msgstr "A fatal error occurred on the interface between a MBC chip and a SC chip.\n Refer to %s for more information."
1172 msgid "SCF-8003-GJ.response"
1173 msgstr "Resources associated with the faulty FRU will be deconfigured. Please consult the \ndetail section of the knowledge article for additional information.\n"
1174 msgid "SCF-8003-GJ.impact"
1175 msgstr "Either the platform or a domain is reset. The platform may become unbootable.\nPlease consult the detail section of the knowledge article for additional information.\n"
1176 msgid "SCF-8003-GJ.action"
1177 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1180 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.fe
1182 msgid "SCF-8003-HA.type"
1184 msgid "SCF-8003-HA.severity"
1186 msgid "SCF-8003-HA.description"
1187 msgstr "A fatal error was detected within a MBC chip.\n Refer to %s for more information."
1188 msgid "SCF-8003-HA.response"
1189 msgstr "Resources associated with the faulty FRU will be deconfigured. Please consult the \ndetail section of the knowledge article for additional information.\n"
1190 msgid "SCF-8003-HA.impact"
1191 msgstr "Either the platform will be reset or a domain may be reset. The platform may become unbootable.\nPlease consult the detail section of the knowledge article for additional information.\n"
1192 msgid "SCF-8003-HA.action"
1193 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1196 # keys: fault.chassis.SPARC-Enterprise.if.se-mbc-sc
1198 msgid "SCF-8003-JP.type"
1200 msgid "SCF-8003-JP.severity"
1202 msgid "SCF-8003-JP.description"
1203 msgstr "A non-fatal uncorrectable error occurred on the interface between a MBC chip and a SC chip.\n Refer to %s for more information."
1204 msgid "SCF-8003-JP.response"
1205 msgstr "No immediate action is taken by XSCF software due to this fault.\nResources associated with the faulty FRU will be deconfigured after the platform is\npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed. This resource deconfiguration may cause the platform to become\nunbootable. Please consult the detail section of the knowledge article for additional information.\n"
1206 msgid "SCF-8003-JP.impact"
1207 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \n"
1208 msgid "SCF-8003-JP.action"
1209 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1212 # keys: fault.chassis.SPARC-Enterprise.if.se-mbc-xscf
1214 msgid "SCF-8003-K5.type"
1216 msgid "SCF-8003-K5.severity"
1218 msgid "SCF-8003-K5.description"
1219 msgstr "A non-fatal uncorrectable error occurred on the interface between a MBC chip and the XSCF.\n Refer to %s for more information."
1220 msgid "SCF-8003-K5.response"
1221 msgstr "No immediate action is taken by XSCF software due to this fault.\nResources associated with the faulty FRU will be deconfigured after the platform is\npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed. This resource deconfiguration may cause the platform to become\nunbootable. Please consult the detail section of the knowledge article for additional information.\n"
1222 msgid "SCF-8003-K5.impact"
1223 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \n"
1224 msgid "SCF-8003-K5.action"
1225 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1228 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.se
1230 msgid "SCF-8003-LS.type"
1232 msgid "SCF-8003-LS.severity"
1234 msgid "SCF-8003-LS.description"
1235 msgstr "A non-fatal uncorrectable error was detected within a MBC chip.\n Refer to %s for more information."
1236 msgid "SCF-8003-LS.response"
1237 msgstr "No immediate action is taken by XSCF software due to this fault.\nResources associated with the faulty FRU will be deconfigured after the platform is\npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed. This resource deconfiguration may cause the platform to become\nunbootable. Please consult the detail section of the knowledge article for additional information.\n"
1238 msgid "SCF-8003-LS.impact"
1239 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \n"
1240 msgid "SCF-8003-LS.action"
1241 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1244 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.se-dma
1246 msgid "SCF-8003-M3.type"
1248 msgid "SCF-8003-M3.severity"
1250 msgid "SCF-8003-M3.description"
1251 msgstr "An uncorrectable error was detected on a DMA channel between two MBC chips on two\ndifferent FRUs. Please consult the detail section of the knowledge article for additional information.\n Refer to %s for more information."
1252 msgid "SCF-8003-M3.response"
1253 msgstr "There are two DMA channels between MBC chips. If the first DMA channel fails, the system\nwill switch to using the second DMA channel. If the second DMA channel fails, then the\nFRU with the MBC chip becomes unmanageable. If the second DMA channel fails, then resources\nassociated with the FRU with the MBC chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\nDeconfiguration of these resources may reduce system performance or may cause the\nplatform to become unbootable. Please consult the detail section of the knowledge article for \nadditional information.\n"
1254 msgid "SCF-8003-M3.impact"
1255 msgstr "If it is the second DMA channel for the MBC chip that has failed, the XSCF will no longer be able \nto contact the chips and devices that are connected to the faulty MBC chip.\n"
1256 msgid "SCF-8003-M3.action"
1257 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1260 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.se-dma-dscp
1262 msgid "SCF-8003-NY.type"
1264 msgid "SCF-8003-NY.severity"
1266 msgid "SCF-8003-NY.description"
1267 msgstr "A non-fatal uncorrectable internal error was detected on the DMA interface used by DSCP \non a MBC chip.\n Refer to %s for more information."
1268 msgid "SCF-8003-NY.response"
1269 msgstr "DSCP will switch to use some other XSB's DMA interface, if there is an operational DMA interface\non another XSB in this domain. Otherwise, the system will continue to use the existing DMA interface.\nThe XSB with this DMA interface will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\nPlease consult the detail section of the knowledge article for additional information.\n"
1270 msgid "SCF-8003-NY.impact"
1271 msgstr "The domain may encounter an uncorrectable error, but the domain will not panic.\n"
1272 msgid "SCF-8003-NY.action"
1273 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1276 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.se-cmd
1278 msgid "SCF-8003-PD.type"
1280 msgid "SCF-8003-PD.severity"
1282 msgid "SCF-8003-PD.description"
1283 msgstr "XSCF software detected a problem on the command interface between the XSCF and an XSB.\n Refer to %s for more information."
1284 msgid "SCF-8003-PD.response"
1285 msgstr "If the problem can be isolated to a specific XSB, the system will switch to use some other XSB's \ncommand interface, if there is an operational command interface on another XSB in this domain. Otherwise, \nthe system will continue to use the existing command interface. The XSB with this command interface will \nbe deconfigured after the platform is power cycled or after the domain reboots or after a Dynamic \nReconfiguration operation is performed. If the problem cannot be isolated to a specific XSB, no\ndeconfiguration is performed. Please consult the detail section of the knowledge article for additional \ninformation.\n"
1286 msgid "SCF-8003-PD.impact"
1287 msgstr "No immediate impact.\n"
1288 msgid "SCF-8003-PD.action"
1289 msgstr "If the problem can be isolated to a specific XSB, schedule a repair action to replace the affected \nField Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1292 # keys: fault.chassis.SPARC-Enterprise.if.ce-mbc-sc
1294 msgid "SCF-8003-QH.type"
1296 msgid "SCF-8003-QH.severity"
1298 msgid "SCF-8003-QH.description"
1299 msgstr "The number of correctable errors on the interface between a MBC chip and a SC chip has exceeded \nan acceptable threshold.\n Refer to %s for more information."
1300 msgid "SCF-8003-QH.response"
1301 msgstr "Resources associated with this SC chip (this includes CPU chips, memory, and I/O) will be deconfigured\nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration \noperation is performed. Please consult the detail section of the knowledge article for additional information.\n"
1302 msgid "SCF-8003-QH.impact"
1303 msgstr "No immediate action. Resources associated with this SC chip (this includes CPU chips, memory, and I/O) \nwill be deconfigured after the platform is power cycled or after the domain reboots or after a Dynamic \nReconfiguration operation is performed. Please consult the detail section of the knowledge article for \nadditional information.\n"
1304 msgid "SCF-8003-QH.action"
1305 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1308 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.ce
1310 msgid "SCF-8003-RR.type"
1312 msgid "SCF-8003-RR.severity"
1314 msgid "SCF-8003-RR.description"
1315 msgstr "The number of correctable errors within the SRAM of a MBC chip has exceeded an acceptable threshold.\n Refer to %s for more information."
1316 msgid "SCF-8003-RR.response"
1317 msgstr "The resources associated with this MBC chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for \nadditional information.\n"
1318 msgid "SCF-8003-RR.impact"
1319 msgstr "No immediate impact.\n"
1320 msgid "SCF-8003-RR.action"
1321 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1324 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.test
1326 msgid "SCF-8003-S4.type"
1328 msgid "SCF-8003-S4.severity"
1330 msgid "SCF-8003-S4.description"
1331 msgstr "An error was detected within the section of a MBC chip dealing with a specific\nXSB. This error is detected during self-test.\n Refer to %s for more information."
1332 msgid "SCF-8003-S4.response"
1333 msgstr "The XSB is deconfigured.\n"
1334 msgid "SCF-8003-S4.impact"
1335 msgstr "No immediate impact. The XSB is deconfigured.\n"
1336 msgid "SCF-8003-S4.action"
1337 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1340 # keys: fault.chassis.SPARC-Enterprise.asic.mac.power.fail
1342 msgid "SCF-8004-3Y.type"
1344 msgid "SCF-8004-3Y.severity"
1346 msgid "SCF-8004-3Y.description"
1347 msgstr "The MAC chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1348 msgid "SCF-8004-3Y.response"
1349 msgstr "Nothing is deconfigured.\n"
1350 msgid "SCF-8004-3Y.impact"
1351 msgstr "The domain using the MAC chip will be reset.\n"
1352 msgid "SCF-8004-3Y.action"
1353 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1356 # keys: fault.chassis.SPARC-Enterprise.asic.sc.power.fail
1358 msgid "SCF-8004-45.type"
1360 msgid "SCF-8004-45.severity"
1362 msgid "SCF-8004-45.description"
1363 msgstr "The SC chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1364 msgid "SCF-8004-45.response"
1365 msgstr "Resources may be deconfigured after a platform reset.\nPlease consult the detail section of the knowledge article for additional information.\n"
1366 msgid "SCF-8004-45.impact"
1367 msgstr "Either the platform or a domain will be reset. Please consult the detail section of the \nknowledge article for additional information.\n"
1368 msgid "SCF-8004-45.action"
1369 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1372 # keys: fault.chassis.SPARC-Enterprise.asic.xb.power.fail
1374 msgid "SCF-8004-5S.type"
1376 msgid "SCF-8004-5S.severity"
1378 msgid "SCF-8004-5S.description"
1379 msgstr "The XB chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1380 msgid "SCF-8004-5S.response"
1381 msgstr "Resources may be deconfigured after a platform reset.\nPlease consult the detail section of the knowledge article for additional information.\n"
1382 msgid "SCF-8004-5S.impact"
1383 msgstr "The platform will be reset.\n"
1384 msgid "SCF-8004-5S.action"
1385 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1388 # keys: fault.chassis.SPARC-Enterprise.asic.ioc.power.fail
1390 msgid "SCF-8004-6A.type"
1392 msgid "SCF-8004-6A.severity"
1394 msgid "SCF-8004-6A.description"
1395 msgstr "The IOC chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1396 msgid "SCF-8004-6A.response"
1397 msgstr "Nothing is deconfigured.\nPlease consult the detail section of the knowledge article for additional information.\n"
1398 msgid "SCF-8004-6A.impact"
1399 msgstr "The domains using the IOC chip will be reset.\n"
1400 msgid "SCF-8004-6A.action"
1401 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1404 # keys: fault.chassis.SPARC-Enterprise.asic.clk.power.fail
1406 msgid "SCF-8004-7P.type"
1408 msgid "SCF-8004-7P.severity"
1410 msgid "SCF-8004-7P.description"
1411 msgstr "The Clock chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1412 msgid "SCF-8004-7P.response"
1413 msgstr "Nothing is deconfigured.\nPlease consult the detail section of the knowledge article for additional information.\n"
1414 msgid "SCF-8004-7P.impact"
1415 msgstr "The platform will be reset.\n"
1416 msgid "SCF-8004-7P.action"
1417 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1420 # keys: fault.chassis.SPARC-Enterprise.asic.cpu.power.fail
1422 msgid "SCF-8004-8X.type"
1424 msgid "SCF-8004-8X.severity"
1426 msgid "SCF-8004-8X.description"
1427 msgstr "A CPU chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1428 msgid "SCF-8004-8X.response"
1429 msgstr "Nothing is deconfigured.\nPlease consult the detail section of the knowledge article for additional information.\n"
1430 msgid "SCF-8004-8X.impact"
1431 msgstr "The domain using the CPU chip will reset.\n"
1432 msgid "SCF-8004-8X.action"
1433 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1436 # keys: fault.chassis.SPARC-Enterprise.asic.flp.power.fail
1438 msgid "SCF-8004-92.type"
1440 msgid "SCF-8004-92.severity"
1442 msgid "SCF-8004-92.description"
1443 msgstr "A FLP chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1444 msgid "SCF-8004-92.response"
1445 msgstr "Nothing is deconfigured.\nPlease consult the detail section of the knowledge article for additional information.\n"
1446 msgid "SCF-8004-92.impact"
1447 msgstr "The domain using the FLP chip will be reset.\n"
1448 msgid "SCF-8004-92.action"
1449 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1452 # keys: fault.chassis.SPARC-Enterprise.asic.mbc.power.fail
1454 msgid "SCF-8004-AJ.type"
1456 msgid "SCF-8004-AJ.severity"
1458 msgid "SCF-8004-AJ.description"
1459 msgstr "A MBC chip has detected it does not have sufficient power to continue operating.\n Refer to %s for more information."
1460 msgid "SCF-8004-AJ.response"
1461 msgstr "Nothing is deconfigured.\nPlease consult the detail section of the knowledge article for additional information.\n"
1462 msgid "SCF-8004-AJ.impact"
1463 msgstr "Either the platform or a domain will be reset. Please consult the detail section of \nthe knowledge article for additional information.\n"
1464 msgid "SCF-8004-AJ.action"
1465 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1468 # keys: fault.chassis.SPARC-Enterprise.asic.power.fail
1470 msgid "SCF-8004-CE.type"
1472 msgid "SCF-8004-CE.severity"
1474 msgid "SCF-8004-CE.description"
1475 msgstr "Some ASIC has detected it does not have sufficient power to continue operating. It is unknown\nwhich type of ASIC detected the falure.\n Refer to %s for more information."
1476 msgid "SCF-8004-CE.response"
1477 msgstr "Nothing is deconfigured.\nPlease consult the detail section of the knowledge article for additional information.\n"
1478 msgid "SCF-8004-CE.impact"
1479 msgstr "Either the platform or a domain will be reset. Please consult the detail section of \nthe knowledge article for additional information.\n"
1480 msgid "SCF-8004-CE.action"
1481 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
1484 # keys: fault.chassis.power.warning
1486 msgid "SCF-8004-DQ.type"
1488 msgid "SCF-8004-DQ.severity"
1490 msgid "SCF-8004-DQ.description"
1491 msgstr "An undervoltage or overvoltage warning was detected by a device or FRU.\n Refer to %s for more information."
1492 msgid "SCF-8004-DQ.response"
1493 msgstr "Nothing is deconfigured and no action is taken as a result of this warning.\n"
1494 msgid "SCF-8004-DQ.impact"
1496 msgid "SCF-8004-DQ.action"
1497 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1500 # keys: fault.chassis.power.undervoltage
1502 msgid "SCF-8004-EC.type"
1504 msgid "SCF-8004-EC.severity"
1506 msgid "SCF-8004-EC.description"
1507 msgstr "A serious undervoltage failure has occurred on a device or FRU.\n Refer to %s for more information."
1508 msgid "SCF-8004-EC.response"
1509 msgstr "The device or FRU will be deconfigured. Please consult the detail section of the \nknowledge article for additional information.\n"
1510 msgid "SCF-8004-EC.impact"
1511 msgstr "Domains may be reset, platform may become unbootable, or the platform may be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
1512 msgid "SCF-8004-EC.action"
1513 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1516 # keys: fault.chassis.power.power-off
1518 msgid "SCF-8004-FR.type"
1520 msgid "SCF-8004-FR.severity"
1522 msgid "SCF-8004-FR.description"
1523 msgstr "An attempt to power-off a FRU or a device has failed during a power-off sequence. \nPlease consult the detail section of the knowledge article for additional information.\n Refer to %s for more information."
1524 msgid "SCF-8004-FR.response"
1525 msgstr "The poweroff sequence continues. The FRU or device will be deconfigured and will\nnot be powered up during the next power-on sequence. Please consult the detail section \nof the knowledge article for additional information.\n"
1526 msgid "SCF-8004-FR.impact"
1527 msgstr "Platform may become unbootable. Please consult the detail section of the knowledge \narticle for additional information.\n"
1528 msgid "SCF-8004-FR.action"
1529 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1532 # keys: fault.chassis.device.fail
1534 msgid "SCF-8004-G4.type"
1536 msgid "SCF-8004-G4.severity"
1538 msgid "SCF-8004-G4.description"
1539 msgstr "A component in a FRU has signaled it has failed. Please consult the detail section of \nthe knowledge article for additional information.\n Refer to %s for more information."
1540 msgid "SCF-8004-G4.response"
1541 msgstr "The component in the FRU will be deconfigured (which may cause the FRU to be deconfigured). Please \nconsult the detail section of the knowledge article for additional information.\n"
1542 msgid "SCF-8004-G4.impact"
1543 msgstr "Domains may be reset, the platform may become unbootable, or the platform may be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
1544 msgid "SCF-8004-G4.action"
1545 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1548 # keys: fault.chassis.device.misconfig
1550 msgid "SCF-8004-HY.type"
1552 msgid "SCF-8004-HY.severity"
1554 msgid "SCF-8004-HY.description"
1555 msgstr "An misconfigured FRU or device has been detected during powerup. Please consult the detail \nsection of the knowledge article for additional information.\n Refer to %s for more information."
1556 msgid "SCF-8004-HY.response"
1557 msgstr "The misconfigured FRU or device will not be powered up. Please consult the detail section of \nthe knowledge article for additional information.\n"
1558 msgid "SCF-8004-HY.impact"
1559 msgstr "The misconfigured FRU or device will not be powered up. The platform may not powerup.\nPlease consult the detail section of the knowledge article for additional information.\n"
1560 msgid "SCF-8004-HY.action"
1561 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1564 # keys: fault.chassis.device.missing
1566 msgid "SCF-8004-J3.type"
1568 msgid "SCF-8004-J3.severity"
1570 msgid "SCF-8004-J3.description"
1571 msgstr "A FRU or device is missing or could not be detected during powerup. Please consult the detail section \nof the knowledge article for additional information.\n Refer to %s for more information."
1572 msgid "SCF-8004-J3.response"
1573 msgstr "If the device is not redundant, powerup of the FRU will be rejected.\nPlease consult the detail section of the knowledge article for additional information.\n"
1574 msgid "SCF-8004-J3.impact"
1575 msgstr "The powerup request for FRU or device may be rejected, or the entire platform may not be powered up.\nPlease consult the detail section of the knowledge article for additional information.\n"
1576 msgid "SCF-8004-J3.action"
1577 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1580 # keys: fault.chassis.device.inserted
1582 msgid "SCF-8004-KH.type"
1584 msgid "SCF-8004-KH.severity"
1586 msgid "SCF-8004-KH.description"
1587 msgstr "A FRU's presence was unexpectedly detected. This may be caused by insertion\nof the FRU without following the correct procedure. Please consult the detail section of the \nknowledge article for additional information.\n Refer to %s for more information."
1588 msgid "SCF-8004-KH.response"
1589 msgstr "Nothing is deconfigured and no immediate action is taken. The FRU will not be\nconfigured into the system.\n"
1590 msgid "SCF-8004-KH.impact"
1592 msgid "SCF-8004-KH.action"
1593 msgstr "If the FRU was inserted without following correct procedure, please use the\ncorrect procedure. Otherwise, schedule a repair action to replace the affected Field \nReplaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1596 # keys: fault.chassis.device.removed
1598 msgid "SCF-8004-LD.type"
1600 msgid "SCF-8004-LD.severity"
1602 msgid "SCF-8004-LD.description"
1603 msgstr "A FRU's presence detect signal has suddenly disappeared. This may be caused\nby removal of the FRU without following the correct procedure.\nPlease consult the detail section of the knowledge article for additional information.\n Refer to %s for more information."
1604 msgid "SCF-8004-LD.response"
1605 msgstr "The FRU will be deconfigured. Please consult the detail section of the \nknowledge article for additional information.\n"
1606 msgid "SCF-8004-LD.impact"
1607 msgstr "The platform may be reset, or the platform may be powered down, or a domain may be reset.\nPlease consult the detail section of the knowledge article for additional information.\n"
1608 msgid "SCF-8004-LD.action"
1609 msgstr "If the FRU has not been removed without following the correct procedure,\nschedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1612 # keys: fault.chassis.env.power.loss
1614 msgid "SCF-8004-MP.type"
1616 msgid "SCF-8004-MP.severity"
1618 msgid "SCF-8004-MP.description"
1619 msgstr "PSU has detected a loss of AC power.\n Refer to %s for more information."
1620 msgid "SCF-8004-MP.response"
1621 msgstr "The PSU will be deconfigured. If sufficient operational PSU's remain, the fan speeds of\nall fans will be increased. Please consult the detail section of the knowledge article for \nadditional information.\n"
1622 msgid "SCF-8004-MP.impact"
1623 msgstr "If there are insufficient operational PSU's, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
1624 msgid "SCF-8004-MP.action"
1625 msgstr "The platform administrator should check the AC power connections and schedule a \nservice action, if necessary. Please consult the detail section of the knowledge article \nfor additional information.\n"
1628 # keys: fault.chassis.env.power.ups
1630 msgid "SCF-8004-NA.type"
1632 msgid "SCF-8004-NA.severity"
1634 msgid "SCF-8004-NA.description"
1635 msgstr "Problems have been detected with an external UPS.\n Refer to %s for more information."
1636 msgid "SCF-8004-NA.response"
1637 msgstr "Nothing is deconfigured and no immediate action is taken.\n"
1638 msgid "SCF-8004-NA.impact"
1640 msgid "SCF-8004-NA.action"
1641 msgstr "The platform administrator should investigate the UPS.\n"
1644 # keys: fault.chassis.SPARC-Enterprise.rci
1646 msgid "SCF-8004-Q5.type"
1648 msgid "SCF-8004-Q5.severity"
1650 msgid "SCF-8004-Q5.description"
1651 msgstr "Error detected by an RCI device on the RCI Network.\n Refer to %s for more information."
1652 msgid "SCF-8004-Q5.response"
1653 msgstr "Nothing is deconfigured. The entire system may be powered down or there may be no \ncommunication with RCI devices. Please consult the detail section of the knowledge article \nfor additional information.\n"
1654 msgid "SCF-8004-Q5.impact"
1655 msgstr "The entire system may be powered down or there may be no communication with RCI devices.\nPlease consult the detail section of the knowledge article for additional information.\n"
1656 msgid "SCF-8004-Q5.action"
1657 msgstr "The platform administrator should use the output of the showlogs command to determine\nwhat type of service action is necessary. Please consult the detail section of the knowledge\narticle for additional information.\n"
1660 # keys: fault.chassis.SPARC-Enterprise.asic.sc.fe-multicmu
1662 msgid "SCF-8005-0C.type"
1664 msgid "SCF-8005-0C.severity"
1666 msgid "SCF-8005-0C.description"
1667 msgstr "A fatal error was detected within a SC chip. This error may affect multiple CMU's.\n Refer to %s for more information."
1668 msgid "SCF-8005-0C.response"
1669 msgstr "The CMU that contains this SC chip and all its associated IO are deconfigured.\n"
1670 msgid "SCF-8005-0C.impact"
1671 msgstr "One or more domains are reset. Please consult the detail section of the knowledge article for \nadditional information.\n"
1672 msgid "SCF-8005-0C.action"
1673 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1676 # keys: fault.chassis.SPARC-Enterprise.if.fe-cpu-sc
1678 msgid "SCF-8005-1Q.type"
1680 msgid "SCF-8005-1Q.severity"
1682 msgid "SCF-8005-1Q.description"
1683 msgstr "A fatal error occurred on the interface between a CPU chip and a SC chip.\n Refer to %s for more information."
1684 msgid "SCF-8005-1Q.response"
1685 msgstr "The CPU chip is deconfigured.\n"
1686 msgid "SCF-8005-1Q.impact"
1687 msgstr "The single domain using the CPU chip is reset.\n"
1688 msgid "SCF-8005-1Q.action"
1689 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1692 # keys: fault.chassis.SPARC-Enterprise.if.fe-sc-cpu
1694 msgid "SCF-8005-24.type"
1696 msgid "SCF-8005-24.severity"
1698 msgid "SCF-8005-24.description"
1699 msgstr "A fatal error occurred on the interface between a SC chip and a CPU chip.\n Refer to %s for more information."
1700 msgid "SCF-8005-24.response"
1701 msgstr "The CPU chip is deconfigured.\n"
1702 msgid "SCF-8005-24.impact"
1703 msgstr "The single domain using the CPU chip is reset.\n"
1704 msgid "SCF-8005-24.action"
1705 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1708 # keys: fault.chassis.SPARC-Enterprise.if.fe-sc-xb
1710 msgid "SCF-8005-3R.type"
1712 msgid "SCF-8005-3R.severity"
1714 msgid "SCF-8005-3R.description"
1715 msgstr "A fatal error occurred on the interface between a SC chip and a XB chip.\n Refer to %s for more information."
1716 msgid "SCF-8005-3R.response"
1717 msgstr "The CMU containing the SC chip along with all its associated IO is deconfigured.\n"
1718 msgid "SCF-8005-3R.impact"
1719 msgstr "All domains using the CMU are reset.\n"
1720 msgid "SCF-8005-3R.action"
1721 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1724 # keys: fault.chassis.SPARC-Enterprise.if.fe-mac-sc
1726 msgid "SCF-8005-5X.type"
1728 msgid "SCF-8005-5X.severity"
1730 msgid "SCF-8005-5X.description"
1731 msgstr "A fatal error occurred on the interface between a MAC chip and a SC chip.\n Refer to %s for more information."
1732 msgid "SCF-8005-5X.response"
1733 msgstr "Memory associated with the MAC chip is deconfigured.\n"
1734 msgid "SCF-8005-5X.impact"
1735 msgstr "One or more domains will be reset. Please consult the detail section of the knowledge \narticle for additional information.\n"
1736 msgid "SCF-8005-5X.action"
1737 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1740 # keys: fault.chassis.SPARC-Enterprise.if.fe-sc-mac
1742 msgid "SCF-8005-6E.type"
1744 msgid "SCF-8005-6E.severity"
1746 msgid "SCF-8005-6E.description"
1747 msgstr "A fatal error occurred on the interface between a SC chip and a MAC chip.\n Refer to %s for more information."
1748 msgid "SCF-8005-6E.response"
1749 msgstr "Memory associated with the MAC chip is deconfigured.\n"
1750 msgid "SCF-8005-6E.impact"
1751 msgstr "One or more domains will be reset. Please consult the detail section of the knowledge \narticle for additional information.\n"
1752 msgid "SCF-8005-6E.action"
1753 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1756 # keys: fault.chassis.SPARC-Enterprise.if.fe-macbank-sc
1758 msgid "SCF-8005-7J.type"
1760 msgid "SCF-8005-7J.severity"
1762 msgid "SCF-8005-7J.description"
1763 msgstr "A fatal error occurred on the interface between a SC chip and the portion of the MAC chip \ninterfaces with a single memory bank.\n Refer to %s for more information."
1764 msgid "SCF-8005-7J.response"
1765 msgstr "Memory associated with the memory bank is deconfigured.\n"
1766 msgid "SCF-8005-7J.impact"
1767 msgstr "One or more domains will be reset. Please consult the detail section of the knowledge \narticle for additional information.\n"
1768 msgid "SCF-8005-7J.action"
1769 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1772 # keys: fault.chassis.SPARC-Enterprise.if.fe-ioc-sc
1774 msgid "SCF-8005-8S.type"
1776 msgid "SCF-8005-8S.severity"
1778 msgid "SCF-8005-8S.description"
1779 msgstr "A fatal error occurred on the interface between an IO Channel and a SC chip.\n Refer to %s for more information."
1780 msgid "SCF-8005-8S.response"
1781 msgstr "The IO Channel is deconfigured.\n"
1782 msgid "SCF-8005-8S.impact"
1783 msgstr "The domain that is using the IO Channel is reset.\n"
1784 msgid "SCF-8005-8S.action"
1785 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1788 # keys: fault.chassis.SPARC-Enterprise.if.fe-sc-ioc
1790 msgid "SCF-8005-95.type"
1792 msgid "SCF-8005-95.severity"
1794 msgid "SCF-8005-95.description"
1795 msgstr "A fatal error occurred on the interface between a SC chip and an IO Channel.\n Refer to %s for more information."
1796 msgid "SCF-8005-95.response"
1797 msgstr "The IO Channel is deconfigured.\n"
1798 msgid "SCF-8005-95.impact"
1799 msgstr "The domain that is using the IO Channel is reset.\n"
1800 msgid "SCF-8005-95.action"
1801 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1804 # keys: fault.chassis.SPARC-Enterprise.if.fe-sc-sc
1806 msgid "SCF-8005-AP.type"
1808 msgid "SCF-8005-AP.severity"
1810 msgid "SCF-8005-AP.description"
1811 msgstr "A fatal error on the interface between two SC chips has occurred.\n Refer to %s for more information."
1812 msgid "SCF-8005-AP.response"
1813 msgstr "Some number of CPU chips, some number of MAC chips, and some amount of IO will be deconfigured.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for \nadditional information.\n"
1814 msgid "SCF-8005-AP.impact"
1815 msgstr "One or more domains will be reset. The platform may become unbootable. \nPlease consult the detail section of the knowledge article for additional information.\n"
1816 msgid "SCF-8005-AP.action"
1817 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1820 # keys: fault.chassis.SPARC-Enterprise.asic.sc.fe
1822 msgid "SCF-8005-CA.type"
1824 msgid "SCF-8005-CA.severity"
1826 msgid "SCF-8005-CA.description"
1827 msgstr "A fatal error was detected within a SC chip.\n Refer to %s for more information."
1828 msgid "SCF-8005-CA.response"
1829 msgstr "Some number of CPU chips, some number of MAC chips, and some amount of IO will be deconfigured.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for \nadditional information.\n"
1830 msgid "SCF-8005-CA.impact"
1831 msgstr "One or more domains will be reset. The platform may become unbootable. Please consult the \ndetail section of the knowledge article for additional information.\n"
1832 msgid "SCF-8005-CA.action"
1833 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1836 # keys: fault.chassis.SPARC-Enterprise.asic.sc.se
1838 msgid "SCF-8005-DH.type"
1840 msgid "SCF-8005-DH.severity"
1842 msgid "SCF-8005-DH.description"
1843 msgstr "A non-fatal uncorrectable error was detected within a SC chip.\n Refer to %s for more information."
1844 msgid "SCF-8005-DH.response"
1845 msgstr "Nothing is deconfigured.\n"
1846 msgid "SCF-8005-DH.impact"
1847 msgstr "No immediate action is taken as a result of this fault. The domain may not\nbe operational. Please consult the detail section of the knowledge article for additional information.\n"
1848 msgid "SCF-8005-DH.action"
1849 msgstr "The platform administrator should investigate and see if there is some other\nhardware fault that might possibly be related to this fault.\nPlease consult the detail section of the knowledge article for additional information.\n"
1852 # keys: fault.chassis.SPARC-Enterprise.if.ce-cpu-sc
1854 msgid "SCF-8005-ED.type"
1856 msgid "SCF-8005-ED.severity"
1858 msgid "SCF-8005-ED.description"
1859 msgstr "The number of correctable errors on the interface between a CPU chip and a SC chip \nhas exceeded an acceptable threshold.\n Refer to %s for more information."
1860 msgid "SCF-8005-ED.response"
1861 msgstr "The CPU chip is deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1862 msgid "SCF-8005-ED.impact"
1863 msgstr "No immediate impact. The CPU chip is deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1864 msgid "SCF-8005-ED.action"
1865 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1868 # keys: fault.chassis.SPARC-Enterprise.if.ce-sc-xb
1870 msgid "SCF-8005-FY.type"
1872 msgid "SCF-8005-FY.severity"
1874 msgid "SCF-8005-FY.description"
1875 msgstr "The number of correctable errors on the interface between a SC chip and a XB chip \nhas exceeded an acceptable threshold.\n Refer to %s for more information."
1876 msgid "SCF-8005-FY.response"
1877 msgstr "The CMU and all its associated IO are deconfigured after the platform is power cycled or \nafter the domains using the CMU reboot or after a Dynamic Reconfiguration operation is performed.\n"
1878 msgid "SCF-8005-FY.impact"
1879 msgstr "No immediate impact. The CMU and all its associated IO are deconfigured after the platform is power \ncycled or after the domains using the CMU reboot or after a Dynamic Reconfiguration operation is performed.\n"
1880 msgid "SCF-8005-FY.action"
1881 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1884 # keys: fault.chassis.SPARC-Enterprise.if.ce-mac-sc
1886 msgid "SCF-8005-G3.type"
1888 msgid "SCF-8005-G3.severity"
1890 msgid "SCF-8005-G3.description"
1891 msgstr "The number of correctable errors on the interface between a MAC chip and a SC chip\nhas exceeded an acceptable threshold.\n Refer to %s for more information."
1892 msgid "SCF-8005-G3.response"
1893 msgstr "Memory associated with the MAC is deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1894 msgid "SCF-8005-G3.impact"
1895 msgstr "No immediate impact. Memory associated with the MAC is deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
1896 msgid "SCF-8005-G3.action"
1897 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1900 # keys: fault.chassis.SPARC-Enterprise.if.ce-ioc-sc
1902 msgid "SCF-8005-HR.type"
1904 msgid "SCF-8005-HR.severity"
1906 msgid "SCF-8005-HR.description"
1907 msgstr "The number of correctable errors on the interface between an IO Channel and a SC chip \nhas exceeded an acceptable threshold.\n Refer to %s for more information."
1908 msgid "SCF-8005-HR.response"
1909 msgstr "The IO Channel is deconfigured after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
1910 msgid "SCF-8005-HR.impact"
1911 msgstr "No immediate impact. The IO Channel is deconfigured after the platform is power cycled or after the domain \nreboots or after a Dynamic Reconfiguration operation is performed.\n"
1912 msgid "SCF-8005-HR.action"
1913 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1916 # keys: fault.chassis.SPARC-Enterprise.if.ce-sc-sc
1918 msgid "SCF-8005-J4.type"
1920 msgid "SCF-8005-J4.severity"
1922 msgid "SCF-8005-J4.description"
1923 msgstr "The number of correctable errors on the interface between two SC chips has exceeded an acceptable threshold.\n Refer to %s for more information."
1924 msgid "SCF-8005-J4.response"
1925 msgstr "Some resources associated with the SC chips (CPU chips, memory, IO Channels) will be deconfigured\nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for additional information.\n"
1926 msgid "SCF-8005-J4.impact"
1927 msgstr "No immediate impact. Some resources associated with the SC chips (CPU chips, memory, IO Channels) will be deconfigured\nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for additional information.\n"
1928 msgid "SCF-8005-J4.action"
1929 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1932 # keys: fault.chassis.SPARC-Enterprise.asic.sc.ce
1934 msgid "SCF-8005-KQ.type"
1936 msgid "SCF-8005-KQ.severity"
1938 msgid "SCF-8005-KQ.description"
1939 msgstr "The number of correctable errors detected within a SC chip has exceeded an acceptable threshold.\n Refer to %s for more information."
1940 msgid "SCF-8005-KQ.response"
1941 msgstr "Some resources associated with the SC chip (CPU chips, memory, IO Channels) will be deconfigured\nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for additional information.\n"
1942 msgid "SCF-8005-KQ.impact"
1943 msgstr "No immediate impact. Some resources associated with the SC chip (CPU chips, memory, IO Channels) will be deconfigured\nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for additional information.\n"
1944 msgid "SCF-8005-KQ.action"
1945 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1948 # keys: fault.chassis.SPARC-Enterprise.asic.sc.ce-l2tagcpu
1950 msgid "SCF-8005-LC.type"
1952 msgid "SCF-8005-LC.severity"
1954 msgid "SCF-8005-LC.description"
1955 msgstr "The number of correctable errors within the L2 cache tags of a SC chip has exceeded an acceptable threshold.\n Refer to %s for more information."
1956 msgid "SCF-8005-LC.response"
1957 msgstr "One of the L2 cache ways is deconfigured for all the CPU chips associated with this SC chip.\n"
1958 msgid "SCF-8005-LC.impact"
1959 msgstr "The domain is unaffected, except for the performance of the CPU chips.\n"
1960 msgid "SCF-8005-LC.action"
1961 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1964 # keys: fault.chassis.SPARC-Enterprise.asic.sc.test
1966 msgid "SCF-8005-MJ.type"
1968 msgid "SCF-8005-MJ.severity"
1970 msgid "SCF-8005-MJ.description"
1971 msgstr "Self-test error detected within a SC chip or a SC chip interface to another chip.\n Refer to %s for more information."
1972 msgid "SCF-8005-MJ.response"
1973 msgstr "Some number of CPU chips, some number of MAC chips, and some amount of IO will be deconfigured.\nThe platform may become unbootable. Please consult the detail section of the knowledge article for \nadditional information.\n"
1974 msgid "SCF-8005-MJ.impact"
1975 msgstr "Running domains are unaffected by this fault, as this occurs during self-test. The\nplatform may become unbootable. Please consult the detail section of the knowledge article for \nadditional information.\n"
1976 msgid "SCF-8005-MJ.action"
1977 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1980 # keys: defect.chassis.software
1982 msgid "SCF-8005-NE.type"
1984 msgid "SCF-8005-NE.severity"
1986 msgid "SCF-8005-NE.description"
1987 msgstr "An XSCF firmware process has unexpectedly terminated. \n Refer to %s for more information."
1988 msgid "SCF-8005-NE.response"
1989 msgstr "The XSCF firmware will be rebooted.\n"
1990 msgid "SCF-8005-NE.impact"
1991 msgstr "XSCF functionality will be unavailable until the XSCF has restarted.\n"
1992 msgid "SCF-8005-NE.action"
1993 msgstr "Schedule a repair action to upgrade the XCP firmware. Please consult the detail section \nof the knowledge article for additional information.\n"
1996 # keys: upset.chassis.domain.panic
1998 msgid "SCF-8005-PX.type"
2000 msgid "SCF-8005-PX.severity"
2002 msgid "SCF-8005-PX.description"
2003 msgstr "The XSCF has detected that an illumos domain has panic'ed.\n Refer to %s for more information."
2004 msgid "SCF-8005-PX.response"
2005 msgstr "No action is taken due to this fault.\n"
2006 msgid "SCF-8005-PX.impact"
2007 msgstr "The illumos domain has panic'ed.\n"
2008 msgid "SCF-8005-PX.action"
2009 msgstr "The administrator should look at the domain's console to identify the cause of the panic.\nPlease consult the detail section of the knowledge article for additional information.\n"
2012 # keys: upset.chassis.domain.config
2014 msgid "SCF-8005-Q2.type"
2016 msgid "SCF-8005-Q2.severity"
2018 msgid "SCF-8005-Q2.description"
2019 msgstr "The XSB could not be successfully configured into a domain.\n Refer to %s for more information."
2020 msgid "SCF-8005-Q2.response"
2021 msgstr "Nothing is deconfigured.\n"
2022 msgid "SCF-8005-Q2.impact"
2023 msgstr "XSB is not successfully configured into a domain.\n"
2024 msgid "SCF-8005-Q2.action"
2025 msgstr "The platform administrator should investigate why the XSB could not be configured \ninto the domain. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2028 # keys: upset.chassis.domain.post
2030 msgid "SCF-8005-RA.type"
2032 msgid "SCF-8005-RA.severity"
2034 msgid "SCF-8005-RA.description"
2035 msgstr "The XSCF could not determine whether POST is running correctly on a domain/XSB.\n Refer to %s for more information."
2036 msgid "SCF-8005-RA.response"
2037 msgstr "Nothing is deconfigured.\n"
2038 msgid "SCF-8005-RA.impact"
2039 msgstr "The domain or the XSB will be powered down.\n"
2040 msgid "SCF-8005-RA.action"
2041 msgstr "The platform administrator should check for some sort of fault that could have\ncaused this failure. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2044 # keys: upset.chassis.domain.keepalive.msg-fail
2046 msgid "SCF-8005-SP.type"
2048 msgid "SCF-8005-SP.severity"
2050 msgid "SCF-8005-SP.description"
2051 msgstr "Domain does not respond to XSCF keep-alive messages.\n Refer to %s for more information."
2052 msgid "SCF-8005-SP.response"
2053 msgstr "The XSCF will send a message to the domain asking it to panic.\n"
2054 msgid "SCF-8005-SP.impact"
2055 msgstr "The XSCF will send a message to the domain asking it to panic.\n"
2056 msgid "SCF-8005-SP.action"
2057 msgstr "To investigate potential hardware problems, the platform administrator should\nlook at the fault logs on the XSCF to determine if there is some other hardware\nproblem that may be causing the upset. Please consult the detail section of \nthe knowledge article for additional information.\n"
2060 # keys: upset.chassis.domain.tty-overflow
2062 msgid "SCF-8005-T5.type"
2064 msgid "SCF-8005-T5.severity"
2066 msgid "SCF-8005-T5.description"
2067 msgstr "TTY buffer for a domain overflowed, resulting in lost domain console data.\n Refer to %s for more information."
2068 msgid "SCF-8005-T5.response"
2069 msgstr "No action is taken as a result of this fault.\n"
2070 msgid "SCF-8005-T5.impact"
2071 msgstr "Domain console data is lost.\n"
2072 msgid "SCF-8005-T5.action"
2073 msgstr "None. Please consult the detail section of the knowledge article for additional information.\n"
2076 # keys: upset.chassis.domain.keepalive.panic-fail
2078 msgid "SCF-8005-US.type"
2080 msgid "SCF-8005-US.severity"
2082 msgid "SCF-8005-US.description"
2083 msgstr "Domain did not respond to an XSCF request for it to panic.\n Refer to %s for more information."
2084 msgid "SCF-8005-US.response"
2085 msgstr "The XSCF will send an XIR interrupt to the domain.\n"
2086 msgid "SCF-8005-US.impact"
2087 msgstr "The XSCF will send an XIR interrupt to the domain.\n"
2088 msgid "SCF-8005-US.action"
2089 msgstr "The platform administrator should look at the fault logs on the XSCF to determine if there is \nsome hardware problem that may be causing the upset. Please consult the detail section of \nthe knowledge article for additional information.\n"
2092 # keys: upset.chassis.domain.keepalive.xir-fail
2094 msgid "SCF-8005-V3.type"
2096 msgid "SCF-8005-V3.severity"
2098 msgid "SCF-8005-V3.description"
2099 msgstr "Domain did not respond to an XIR interrupt sent by the XSCF.\n Refer to %s for more information."
2100 msgid "SCF-8005-V3.response"
2101 msgstr "The XSCF will attempt to reset the domain.\n"
2102 msgid "SCF-8005-V3.impact"
2103 msgstr "The XSCF will attempt to reset the domain.\n"
2104 msgid "SCF-8005-V3.action"
2105 msgstr "The platform administrator should look at the fault logs on the XSCF to determine if there is \nsome hardware problem that may be causing the upset. Please consult the detail section of \nthe knowledge article for additional information.\n"
2108 # keys: upset.chassis.domain.keepalive.reset-fail
2110 msgid "SCF-8005-WY.type"
2112 msgid "SCF-8005-WY.severity"
2114 msgid "SCF-8005-WY.description"
2115 msgstr "Domain does not respond to the XSCF's request to reset itself.\n Refer to %s for more information."
2116 msgid "SCF-8005-WY.response"
2117 msgstr "The XSCF will power the domain down.\n"
2118 msgid "SCF-8005-WY.impact"
2119 msgstr "The XSCF will power the domain down.\n"
2120 msgid "SCF-8005-WY.action"
2121 msgstr "The platform administrator should look at the fault logs on the XSCF to determine if there is \nsome hardware problem that may be causing the upset. Please consult the detail section of \nthe knowledge article for additional information.\n"
2124 # keys: fault.chassis.device.fan.tooslow
2126 msgid "SCF-8005-YH.type"
2128 msgid "SCF-8005-YH.severity"
2130 msgid "SCF-8005-YH.description"
2131 msgstr "The fan rotation speed for a fan is lower is than its predefined threshold or a fan \nhas stopped completely.\n Refer to %s for more information."
2132 msgid "SCF-8005-YH.response"
2133 msgstr "If there are sufficient fans to maintain normal operation, fan speeds for fans on the \nrest of the platform are raised. If there are insufficient fans to maintain normal\noperation, domains are requested to shut down.\n"
2134 msgid "SCF-8005-YH.impact"
2135 msgstr "If there are insufficient fans to maintain normal operation, domains are sent shutdown requests.\nIf the fan is in a PSU, the PSU is deconfigured.\n"
2136 msgid "SCF-8005-YH.action"
2137 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2140 # keys: fault.chassis.device.fan.speedchange
2142 msgid "SCF-8006-02.type"
2144 msgid "SCF-8006-02.severity"
2146 msgid "SCF-8006-02.description"
2147 msgstr "Fan rotation speed either dropped below a threshold or rose above a threshold during fan speed change\ntesting.\n Refer to %s for more information."
2148 msgid "SCF-8006-02.response"
2149 msgstr "Nothing is deconfigured.\n"
2150 msgid "SCF-8006-02.impact"
2151 msgstr "No action is taken.\n"
2152 msgid "SCF-8006-02.action"
2153 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2156 # keys: fault.chassis.env.temp.under
2158 msgid "SCF-8006-1X.type"
2160 msgid "SCF-8006-1X.severity"
2162 msgid "SCF-8006-1X.description"
2163 msgstr "Under temperature condition detected by the inlet temperature sensor.\n Refer to %s for more information."
2164 msgid "SCF-8006-1X.response"
2165 msgstr "Nothing is deconfigured.\n"
2166 msgid "SCF-8006-1X.impact"
2167 msgstr "System may crash due to ASIC's operating outside their intended temperature ranges.\n"
2168 msgid "SCF-8006-1X.action"
2169 msgstr "The platform administrator should check for the cause of the under temperature condition.\nPlease consult the detail section of the knowledge article for additional information.\n"
2172 # keys: fault.chassis.env.temp.over
2174 msgid "SCF-8006-2E.type"
2176 msgid "SCF-8006-2E.severity"
2178 msgid "SCF-8006-2E.description"
2179 msgstr "Over-temperature condition detected by an inlet temperature sensor, exhaust temperature sensor, \nor CPU temperature sensor.\n Refer to %s for more information."
2180 msgid "SCF-8006-2E.response"
2181 msgstr "Fan speed will be raised for all fans on the platform.\n"
2182 msgid "SCF-8006-2E.impact"
2183 msgstr "No immediate impact.\n"
2184 msgid "SCF-8006-2E.action"
2185 msgstr "Platform administrator should investigate the cause of the over-temperature condition.\nPlease consult the detail section of the knowledge article for additional information.\n"
2188 # keys: fault.chassis.env.temp.over-warn
2190 msgid "SCF-8006-3J.type"
2192 msgid "SCF-8006-3J.severity"
2194 msgid "SCF-8006-3J.description"
2195 msgstr "Over-temperature warning condition has been detected by inlet temperature sensor, exhaust temperature \nsensor, or CPU temperature sensor.\n Refer to %s for more information."
2196 msgid "SCF-8006-3J.response"
2197 msgstr "Fan speed will be raised for all fans on the platform. Shutdown messages will be sent to \ndomains on the platform.\n"
2198 msgid "SCF-8006-3J.impact"
2199 msgstr "Shutdown messages will be sent to domains on the platform.\n"
2200 msgid "SCF-8006-3J.action"
2201 msgstr "Platform administrator should investigate the cause of the over-temperature condition.\nPlease consult the detail section of the knowledge article for additional information.\n"
2204 # keys: fault.chassis.env.temp.over-fail
2206 msgid "SCF-8006-4C.type"
2208 msgid "SCF-8006-4C.severity"
2210 msgid "SCF-8006-4C.description"
2211 msgstr "Dangerous over-temperature condition detected by an exhaust temperature sensor or CPU \ntemperature sensor.\n Refer to %s for more information."
2212 msgid "SCF-8006-4C.response"
2213 msgstr "Nothing is deconfigured. Either the platform will be powered down or specific domains will \nbe powered down. Please consult the detail section of the knowledge article for additional information.\n"
2214 msgid "SCF-8006-4C.impact"
2215 msgstr "Either the platform will be powered down or specific domains will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2216 msgid "SCF-8006-4C.action"
2217 msgstr "Platform administrator should investigate the cause of the over-temperature condition.\nPlease consult the detail section of the knowledge article for additional information.\n"
2220 # keys: fault.chassis.SPARC-Enterprise.if.fe-ioc-xb
2222 msgid "SCF-8006-9D.type"
2224 msgid "SCF-8006-9D.severity"
2226 msgid "SCF-8006-9D.description"
2227 msgstr "A fatal error occurred on an interface between a XB chip and an IOC chip.\n Refer to %s for more information."
2228 msgid "SCF-8006-9D.response"
2229 msgstr "Either the entire IOC chip or a single IO Channel will be deconfigured,\ndepending upon whether a crossbar way was deconfigured prior to the fault.\nPlease consult the detail section of the knowledge article for additional information.\n"
2230 msgid "SCF-8006-9D.impact"
2231 msgstr "One or two domains will be reset, depending upon whether a crossbar way was deconfigured\nprior to the fault. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2232 msgid "SCF-8006-9D.action"
2233 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2236 # keys: fault.chassis.SPARC-Enterprise.if.fe-xb-ioc
2238 msgid "SCF-8006-AY.type"
2240 msgid "SCF-8006-AY.severity"
2242 msgid "SCF-8006-AY.description"
2243 msgstr "A fatal error has occurred on an interface between a SC chip and an IOC chip,\nvia an XB chip.\n Refer to %s for more information."
2244 msgid "SCF-8006-AY.response"
2245 msgstr "Either the entire IOC chip or a single IO Channel will be deconfigured depending upon whether a \ncrossbar way was deconfigured prior to the fault. Please consult the detail section of the \nknowledge article for additional information.\n"
2246 msgid "SCF-8006-AY.impact"
2247 msgstr "One or two domains will be reset, depending upon whether a crossbar way was deconfigured\nprior to the fault. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2248 msgid "SCF-8006-AY.action"
2249 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2252 # keys: fault.chassis.SPARC-Enterprise.if.fe-xb-xbucable
2254 msgid "SCF-8006-C3.type"
2256 msgid "SCF-8006-C3.severity"
2258 msgid "SCF-8006-C3.description"
2259 msgstr "A fatal error has been detected on the cable interface between two XBU's.\n Refer to %s for more information."
2260 msgid "SCF-8006-C3.response"
2261 msgstr "If a crossbar way has been deconfigured, the platform is powered down. Otherwise,\na crossbar way is deconfigured. Please consult the detail section of the knowledge \narticle for additional information.\n"
2262 msgid "SCF-8006-C3.impact"
2263 msgstr "The entire platform is reset. If a crossbar way has been deconfigured, the platform is \npowered down. Otherwise, a crossbar way is deconfigured and the platform continues\nto operate with reduced performance. Please consult the detail section of the \nknowledge article for additional information.\n"
2264 msgid "SCF-8006-C3.action"
2265 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2268 # keys: fault.chassis.SPARC-Enterprise.if.fe-xb-xb
2270 msgid "SCF-8006-DS.type"
2272 msgid "SCF-8006-DS.severity"
2274 msgid "SCF-8006-DS.description"
2275 msgstr "A fatal error has been detected on the interface between two XB chips.\n Refer to %s for more information."
2276 msgid "SCF-8006-DS.response"
2277 msgstr "If the fault can be isolated to a CMU, the CMU and all its associated IO are deconfigured. \nIf the fault cannot be isolated to a single CMU, if a crossbar way has been deconfigured, the platform \nis powered down. Otherwise, a crossbar way is deconfigured and the platform continues to operate with \nreduced performance. Please consult the detail section of the knowledge article for additional information.\n"
2278 msgid "SCF-8006-DS.impact"
2279 msgstr "If the fault can be isolated to a CMU, then one or more domains are reset and the CMU and all\nits associated IO are deconfigured. If the fault cannot be isolated to a single CMU, the entire platform is \nreset. If a crossbar way has been deconfigured, the platform is powered down. Otherwise, a crossbar way \nis deconfigured and the platform continues to operate with reduced performance.\nPlease consult the detail section of the knowledge article for additional information.\n"
2280 msgid "SCF-8006-DS.action"
2281 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2284 # keys: upset.chassis.SPARC-Enterprise.if.fe-xb
2286 msgid "SCF-8006-E5.type"
2288 msgid "SCF-8006-E5.severity"
2290 msgid "SCF-8006-E5.description"
2291 msgstr "A fatal protocol error detected by a XB chip.\n Refer to %s for more information."
2292 msgid "SCF-8006-E5.response"
2293 msgstr "Nothing is deconfigured.\n"
2294 msgid "SCF-8006-E5.impact"
2295 msgstr "The entire platform is reset.\n"
2296 msgid "SCF-8006-E5.action"
2297 msgstr "The component that is at fault is difficult to determine.\nPlease consult the detail section of the knowledge article for additional information.\n"
2300 # keys: fault.chassis.SPARC-Enterprise.asic.xb.fe
2302 msgid "SCF-8006-FP.type"
2304 msgid "SCF-8006-FP.severity"
2306 msgid "SCF-8006-FP.description"
2307 msgstr "A fatal error was detected within a XB chip.\n Refer to %s for more information."
2308 msgid "SCF-8006-FP.response"
2309 msgstr "Depending upon which part of the XB chip is faulty, either a crossbar way is deconfigured,\nor a CMU and all its associated IO are deconfigured, or an IOC chip is deconfigured,\nor an IO Channel within an IOC chip is deconfigured. Please consult the detail section of the \nknowledge article for additional information.\n"
2310 msgid "SCF-8006-FP.impact"
2311 msgstr "Depending upon which part of the XB chip is faulty, either the entire platform is\nreset, or one or more domains are reset. If the response includes deconfiguring a crossbar\nway and this is the first crossbar way to be deconfigured, the platform will operate\nwith reduced performance. If the response includes deconfiguring a crossbar way\nand a crossbar way has already been deconfigured, the platform is powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2312 msgid "SCF-8006-FP.action"
2313 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2316 # keys: fault.chassis.SPARC-Enterprise.if.ce-ioc-xb
2318 msgid "SCF-8006-GA.type"
2320 msgid "SCF-8006-GA.severity"
2322 msgid "SCF-8006-GA.description"
2323 msgstr "The number of correctable errors on the interface between an XB chip and an IOC chip\nhas exceeded an acceptable threshold.\n Refer to %s for more information."
2324 msgid "SCF-8006-GA.response"
2325 msgstr "Depending upon whether a crossbar way has already been deconfigured, either an IOC chip or an\nIOC channel will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\nPlease consult the detail section of the knowledge article for additional information.\n"
2326 msgid "SCF-8006-GA.impact"
2327 msgstr "No immediate impact. Depending upon whether a crossbar way has already been deconfigured, either an IOC \nchip or an IOC channel will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\nPlease consult the detail section of the knowledge article for additional information.\n"
2328 msgid "SCF-8006-GA.action"
2329 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2332 # keys: fault.chassis.SPARC-Enterprise.if.ce-xb-xbucable
2334 msgid "SCF-8006-HJ.type"
2336 msgid "SCF-8006-HJ.severity"
2338 msgid "SCF-8006-HJ.description"
2339 msgstr "The number of correctable errors on the interface between two XB chips communicating\nover an XBU cable has exceeded an acceptable threshold.\n Refer to %s for more information."
2340 msgid "SCF-8006-HJ.response"
2341 msgstr "The crossbar way is deconfigured the next time the platform is restarted. If this is the\nfirst crossbar way to be deconfigured, the platform will operate with reduced performance.\nIf a crossbar way has already been deconfigured, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2342 msgid "SCF-8006-HJ.impact"
2343 msgstr "No immediate impact. The crossbar way is deconfigured the next time the platform is restarted. \nIf this is the first crossbar way to be deconfigured, the platform will operate with reduced \nperformance. If a crossbar way has already been deconfigured, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2344 msgid "SCF-8006-HJ.action"
2345 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2348 # keys: fault.chassis.SPARC-Enterprise.if.ce-xb-xb
2350 msgid "SCF-8006-JE.type"
2352 msgid "SCF-8006-JE.severity"
2354 msgid "SCF-8006-JE.description"
2355 msgstr "The number of correctable errors on the interface between two XB chips on the same XBU\nhas exceeded an acceptable threshold.\n Refer to %s for more information."
2356 msgid "SCF-8006-JE.response"
2357 msgstr "The crossbar way is deconfigured the next time the platform is restarted. If this is the\nfirst crossbar way to be deconfigured, the platform will operate with reduced performance.\nIf a crossbar way has already been deconfigured, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2358 msgid "SCF-8006-JE.impact"
2359 msgstr "No immediate impact. The crossbar way is deconfigured the next time the platform is restarted. \nIf this is the first crossbar way to be deconfigured, the platform will operate with reduced \nperformance. If a crossbar way has already been deconfigured, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2360 msgid "SCF-8006-JE.action"
2361 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2364 # keys: fault.chassis.SPARC-Enterprise.asic.xb.ce
2366 msgid "SCF-8006-KX.type"
2368 msgid "SCF-8006-KX.severity"
2370 msgid "SCF-8006-KX.description"
2371 msgstr "The number of correctable errors within a XB chip has exceeded an acceptable threshold.\n Refer to %s for more information."
2372 msgid "SCF-8006-KX.response"
2373 msgstr "The crossbar way is deconfigured the next time the platform is restarted. If this is the\nfirst crossbar way to be deconfigured, the platform will operate with reduced performance.\nIf a crossbar way has already been deconfigured, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2374 msgid "SCF-8006-KX.impact"
2375 msgstr "No immediate impact. The crossbar way is deconfigured the next time the platform is restarted. \nIf this is the first crossbar way to be deconfigured, the platform will operate with reduced \nperformance. If a crossbar way has already been deconfigured, the platform will be powered down.\nPlease consult the detail section of the knowledge article for additional information.\n"
2376 msgid "SCF-8006-KX.action"
2377 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2380 # keys: fault.chassis.SPARC-Enterprise.asic.xb.test
2382 msgid "SCF-8006-L2.type"
2384 msgid "SCF-8006-L2.severity"
2386 msgid "SCF-8006-L2.description"
2387 msgstr "Self-test error detected within a XB chip or within the interface of the\nXB chip to another chip.\n Refer to %s for more information."
2388 msgid "SCF-8006-L2.response"
2389 msgstr "Depending upon which part of the XB chip is faulty, either a crossbar way is deconfigured,\nor a CMU and all its associated IO are deconfigured, or an IOC chip is deconfigured,\nor an IO Channel within an IOC chip is deconfigured. Please consult the detail section of the \nknowledge article for additional information.\n"
2390 msgid "SCF-8006-L2.impact"
2391 msgstr "Depending upon which part of the XB chip is faulty, either the entire platform is\nreset, or one or more domains are reset. If the response includes deconfiguring a crossbar\nway and this is the first crossbar way to be deconfigured, the platform will operate\nwith reduced performance. If the response includes deconfiguring a crossbar way\nand a crossbar way has already been deconfigured, the platform is powered down.\nDomains are not affected, as this fault can only occur while the platform is powering up.\nPlease consult the detail section of the knowledge article for additional information.\n"
2392 msgid "SCF-8006-L2.action"
2393 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2396 # keys: fault.chassis.SPARC-Enterprise.asic.xb.fe-multicmu
2398 msgid "SCF-8006-MR.type"
2400 msgid "SCF-8006-MR.severity"
2402 msgid "SCF-8006-MR.description"
2403 msgstr "Fatal error detected within a XB chip. This fatal error may affect multiple CMU's.\n Refer to %s for more information."
2404 msgid "SCF-8006-MR.response"
2405 msgstr "The CMU and all its associated IO are deconfigured.\n"
2406 msgid "SCF-8006-MR.impact"
2407 msgstr "The domains running on the CMU that is deconfigured will be reset. Other\ndomains on the platform may also be reset. The CMU and all its associated \nIO are deconfigured.\n"
2408 msgid "SCF-8006-MR.action"
2409 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2412 # keys: fault.chassis.SPARC-Enterprise.xscfu
2414 msgid "SCF-8006-WP.type"
2416 msgid "SCF-8006-WP.severity"
2418 msgid "SCF-8006-WP.description"
2419 msgstr "Hardware problem detected within an XSCFU.\n Refer to %s for more information."
2420 msgid "SCF-8006-WP.response"
2421 msgstr "The platform may become unmanageable. The platform may not be able to reboot. If the configuration\nhas redundant XSCFUs, the XSCF software may fail over to the other XSCFU. If the configuration has\nredundant XSCFUs, XSCFU failover may be disabled. Please consult the detail section of the knowledge \narticle for additional information.\n"
2422 msgid "SCF-8006-WP.impact"
2423 msgstr "The domains will continue to run. The platform may become unmanageable. The platform\nmay not be able to reboot. If the configuration has redundant XSCFUs, the XSCF software may\nfail over to the other XSCFU. If the configuration has redundant XSCFUs, XSCFU failover may\nbe disabled. Please consult the detail section of the knowledge article for additional \ninformation.\n"
2424 msgid "SCF-8006-WP.action"
2425 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2428 # keys: fault.chassis.device.mismatch
2430 msgid "SCF-8006-X5.type"
2432 msgid "SCF-8006-X5.severity"
2434 msgid "SCF-8006-X5.description"
2435 msgstr "The XSCFU_C and XSCFU_B have mismatched board numbers. This problem will only\noccur during platform power-on.\n Refer to %s for more information."
2436 msgid "SCF-8006-X5.response"
2437 msgstr "No domains will be allowed to be powered up until the problem is corrected.\n"
2438 msgid "SCF-8006-X5.impact"
2439 msgstr "The entire platform is unbootable.\n"
2440 msgid "SCF-8006-X5.action"
2441 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2444 # keys: upset.chassis.SPARC-Enterprise.xscfu
2446 msgid "SCF-8006-YS.type"
2448 msgid "SCF-8006-YS.severity"
2450 msgid "SCF-8006-YS.description"
2451 msgstr "A hard-to-diagnose failure of the XSCF has occurred.\n Refer to %s for more information."
2452 msgid "SCF-8006-YS.response"
2453 msgstr "The XSCFU will reboot. If the configuration has redundant XSCFU's, the standby XSCFU \nmay take over as the active XSCFU.\n"
2454 msgid "SCF-8006-YS.impact"
2455 msgstr "The XSCFU will reboot. If the configuration has redundant XSCFU's, the standby XSCFU \nmay take over as the active XSCFU. There is no impact to the domains.\n"
2456 msgid "SCF-8006-YS.action"
2457 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
2460 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.fe
2462 msgid "SCF-8007-05.type"
2464 msgid "SCF-8007-05.severity"
2466 msgid "SCF-8007-05.description"
2467 msgstr "An internal fatal error within a CPU chip was detected.\n Refer to %s for more information."
2468 msgid "SCF-8007-05.response"
2469 msgstr "The domain using this CPU will be reset and the CPU chip will be deconfigured.\n"
2470 msgid "SCF-8007-05.impact"
2471 msgstr "The CPU chip will be deconfigured after the domain is reset.\n"
2472 msgid "SCF-8007-05.action"
2473 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2476 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.fe
2478 msgid "SCF-8007-1S.type"
2480 msgid "SCF-8007-1S.severity"
2482 msgid "SCF-8007-1S.description"
2483 msgstr "An internal fatal error within a core on a CPU chip was detected.\n Refer to %s for more information."
2484 msgid "SCF-8007-1S.response"
2485 msgstr "The domain using this CPU will be reset and the core will be deconfigured.\n"
2486 msgid "SCF-8007-1S.impact"
2487 msgstr "The domain using this CPU chip is reset.\n"
2488 msgid "SCF-8007-1S.action"
2489 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2492 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.strand.fe
2494 msgid "SCF-8007-2A.type"
2496 msgid "SCF-8007-2A.severity"
2498 msgid "SCF-8007-2A.description"
2499 msgstr "An internal fatal error within a strand on a CPU chip was detected.\n Refer to %s for more information."
2500 msgid "SCF-8007-2A.response"
2501 msgstr "The domain using this CPU will be reset and the strand will be deconfigured.\n"
2502 msgid "SCF-8007-2A.impact"
2503 msgstr "The domain using this CPU chip is reset.\n"
2504 msgid "SCF-8007-2A.action"
2505 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2508 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.se
2510 msgid "SCF-8007-3P.type"
2512 msgid "SCF-8007-3P.severity"
2514 msgid "SCF-8007-3P.description"
2515 msgstr "An internal non-fatal uncorrectable error within a CPU chip has been detected.\n Refer to %s for more information."
2516 msgid "SCF-8007-3P.response"
2517 msgstr "The CPU chip will be deconfigured after the platform is power cycled or after the domain reboots \nor after a Dynamic Reconfiguration operation is performed.\n"
2518 msgid "SCF-8007-3P.impact"
2519 msgstr "The non-fatal uncorrectable error may cause domain to panic. The CPU chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
2520 msgid "SCF-8007-3P.action"
2521 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2524 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.se
2526 msgid "SCF-8007-4D.type"
2528 msgid "SCF-8007-4D.severity"
2530 msgid "SCF-8007-4D.description"
2531 msgstr "A non-fatal uncorrectable error associated with a core on a CPU chip has been detected.\n Refer to %s for more information."
2532 msgid "SCF-8007-4D.response"
2533 msgstr "The domain software will attempt to offline the core on the CPU chip.\n"
2534 msgid "SCF-8007-4D.impact"
2535 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic. If the domain\ndoes not panic, the domain software will attempt to offline the core on the CPU chip.\nThe core of the CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
2536 msgid "SCF-8007-4D.action"
2537 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2540 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.se-offlinereq
2542 msgid "SCF-8007-5H.type"
2544 msgid "SCF-8007-5H.severity"
2546 msgid "SCF-8007-5H.description"
2547 msgstr "When a non-fatal uncorrectable error occurs on a core on a CPU chip, domain software attempts to\noffline the core. This fault occurs when the number of offline attempts has exceeded an\nacceptable threshold.\n Refer to %s for more information."
2548 msgid "SCF-8007-5H.response"
2549 msgstr "Future non-fatal uncorrectable errors for this core on a CPU chip will not be recorded on the XSCF.\n"
2550 msgid "SCF-8007-5H.impact"
2551 msgstr "The uncorrectable error trap may cause the domain to panic.\n"
2552 msgid "SCF-8007-5H.action"
2553 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2556 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.strand.se
2558 msgid "SCF-8007-63.type"
2560 msgid "SCF-8007-63.severity"
2562 msgid "SCF-8007-63.description"
2563 msgstr "A non-fatal uncorrectable error has been detected on a strand on a CPU chip.\n Refer to %s for more information."
2564 msgid "SCF-8007-63.response"
2565 msgstr "The strand on the CPU chip is deconfigured.\n"
2566 msgid "SCF-8007-63.impact"
2567 msgstr "The non-fatal uncorrectable error trap may cause the domain to panic.\n"
2568 msgid "SCF-8007-63.action"
2569 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2572 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.ce
2574 msgid "SCF-8007-7Y.type"
2576 msgid "SCF-8007-7Y.severity"
2578 msgid "SCF-8007-7Y.description"
2579 msgstr "The number of correctable errors associated with a CPU chip has exceeded an acceptable threshold.\n Refer to %s for more information."
2580 msgid "SCF-8007-7Y.response"
2581 msgstr "The CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
2582 msgid "SCF-8007-7Y.impact"
2583 msgstr "No immediate impact. The CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
2584 msgid "SCF-8007-7Y.action"
2585 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2588 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.ce
2590 msgid "SCF-8007-8Q.type"
2592 msgid "SCF-8007-8Q.severity"
2594 msgid "SCF-8007-8Q.description"
2595 msgstr "The number of correctable errors associated with a core on a CPU chip have exceeded an acceptable threshold.\n Refer to %s for more information."
2596 msgid "SCF-8007-8Q.response"
2597 msgstr "A request is sent to the domain software to attempt to offline the core on the CPU chip.\nThe core of the CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
2598 msgid "SCF-8007-8Q.impact"
2599 msgstr "No immediate impact.\n"
2600 msgid "SCF-8007-8Q.action"
2601 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2604 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.ce-offlinereq
2606 msgid "SCF-8007-9C.type"
2608 msgid "SCF-8007-9C.severity"
2610 msgid "SCF-8007-9C.description"
2611 msgstr "The number of correctable errors on a core on a CPU chip has exceeded an acceptable threshold. \nThis fault occurs when the number of offline attempts has exceeded an acceptable threshold.\n Refer to %s for more information."
2612 msgid "SCF-8007-9C.response"
2613 msgstr "Future correctable errors for this core on a CPU chip will not be recorded on the XSCF.\n"
2614 msgid "SCF-8007-9C.impact"
2615 msgstr "No immediate impact.\n"
2616 msgid "SCF-8007-9C.action"
2617 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2620 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.way.ce
2622 msgid "SCF-8007-AR.type"
2624 msgid "SCF-8007-AR.severity"
2626 msgid "SCF-8007-AR.description"
2627 msgstr "The number of correctable errors within a way of a CPU chip's L2 cache has exceeded an acceptable threshold.\n Refer to %s for more information."
2628 msgid "SCF-8007-AR.response"
2629 msgstr "The way of the CPU chip's cache is deconfigured. The performance of the CPU chip is reduced.\n"
2630 msgid "SCF-8007-AR.impact"
2631 msgstr "There is a performance loss for the CPU chip.\n"
2632 msgid "SCF-8007-AR.action"
2633 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2636 # keys: upset.chassis.SPARC-Enterprise.cpu.SPARC64-VII.fe
2638 msgid "SCF-8007-C4.type"
2640 msgid "SCF-8007-C4.severity"
2642 msgid "SCF-8007-C4.description"
2643 msgstr "A hard-to-diagnose problem was detected by the CPU chip.\n Refer to %s for more information."
2644 msgid "SCF-8007-C4.response"
2645 msgstr "Nothing is deconfigured.\n"
2646 msgid "SCF-8007-C4.impact"
2647 msgstr "The domain may drop to the OpenBoot PROM 'OK' prompt.\n"
2648 msgid "SCF-8007-C4.action"
2649 msgstr "The platform administrator should check to see if any other hardware failure has occurred on the platform.\nIf the problem occurs while running OpenBoot PROM, then the platform administrator should check to make sure that \nthe OpenBoot PROM environment variables have not been set incorrectly. If neither of these courses of action \nprovide a resolution, then the platform administrator should schedule a service action.\nPlease consult the detail section of the knowledge article for additional information.\n"
2652 # keys: upset.chassis.SPARC-Enterprise.cpu.SPARC64-VII.fe-unexpected-trap
2654 msgid "SCF-8007-DX.type"
2656 msgid "SCF-8007-DX.severity"
2658 msgid "SCF-8007-DX.description"
2659 msgstr "An unexpected trap with some unknown cause was detected by a CPU chip during POST.\n Refer to %s for more information."
2660 msgid "SCF-8007-DX.response"
2661 msgstr "Nothing is deconfigured.\n"
2662 msgid "SCF-8007-DX.impact"
2663 msgstr "The domain is reset.\n"
2664 msgid "SCF-8007-DX.action"
2665 msgstr "Please consult the detail section of the knowledge article for additional information.\n"
2668 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.se-tmo
2670 msgid "SCF-8007-E2.type"
2672 msgid "SCF-8007-E2.severity"
2674 msgid "SCF-8007-E2.description"
2675 msgstr "An internal non-fatal uncorrectable error has been detected within the CPU chip.\n Refer to %s for more information."
2676 msgid "SCF-8007-E2.response"
2677 msgstr "Nothing is deconfigured.\n"
2678 msgid "SCF-8007-E2.impact"
2679 msgstr "The non-fatal uncorrectable error may cause the domain to panic.\n"
2680 msgid "SCF-8007-E2.action"
2681 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2684 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.se-uncertain
2686 msgid "SCF-8007-FJ.type"
2688 msgid "SCF-8007-FJ.severity"
2690 msgid "SCF-8007-FJ.description"
2691 msgstr "An internal non-fatal uncorrectable error has been detected within the CPU chip.\n Refer to %s for more information."
2692 msgid "SCF-8007-FJ.response"
2693 msgstr "Nothing is deconfigured.\n"
2694 msgid "SCF-8007-FJ.impact"
2695 msgstr "The non-fatal uncorrectable error may cause the domain to panic.\n"
2696 msgid "SCF-8007-FJ.action"
2697 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
2700 # keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VII.core.ce-warn
2702 msgid "SCF-8007-GE.type"
2704 msgid "SCF-8007-GE.severity"
2706 msgid "SCF-8007-GE.description"
2707 msgstr "The number of correctable errors associated with a CPU chip has exceeded an acceptable threshold.\n Refer to %s for more information."
2708 msgid "SCF-8007-GE.response"
2709 msgstr "Nothing is deconfigured.\n"
2710 msgid "SCF-8007-GE.impact"
2711 msgstr "No immediate impact.\n"
2712 msgid "SCF-8007-GE.action"
2713 msgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"