dmake: do not set MAKEFLAGS=k
[unleashed/tickless.git] / usr / src / cmd / fm / dicts / SUN4.po
blobb1df0f35b10e2b225f446bdb119811084df25e4a
2 # Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
3 # Use is subject to license terms.
5 # CDDL HEADER START
7 # The contents of this file are subject to the terms of the
8 # Common Development and Distribution License (the "License").
9 # You may not use this file except in compliance with the License.
11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 # or http://www.opensolaris.org/os/licensing.
13 # See the License for the specific language governing permissions
14 # and limitations under the License.
16 # When distributing Covered Code, include this CDDL HEADER in each
17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 # If applicable, add the following below this CDDL HEADER, with the
19 # fields enclosed by brackets "[]" replaced with your own identifying
20 # information: Portions Copyright [yyyy] [name of copyright owner]
22 # CDDL HEADER END
24 # DO NOT EDIT -- this file is generated by the Event Registry.
27 # code: SUN4-8000-0Y
28 # keys: fault.io.fire.asic
30 msgid "SUN4-8000-0Y.type"
31 msgstr "Fault"
32 msgid "SUN4-8000-0Y.severity"
33 msgstr "Critical"
34 msgid "SUN4-8000-0Y.description"
35 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
36 msgid "SUN4-8000-0Y.response"
37 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
38 msgid "SUN4-8000-0Y.impact"
39 msgstr "Loss of services provided by the device instances associated with this fault"
40 msgid "SUN4-8000-0Y.action"
41 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
43 # code: SUN4-8000-13
44 # keys: fault.io.ebus
46 msgid "SUN4-8000-13.type"
47 msgstr "Fault"
48 msgid "SUN4-8000-13.severity"
49 msgstr "Critical"
50 msgid "SUN4-8000-13.description"
51 msgstr "A problem was detected in the Ebus.  Refer to %s for more information."
52 msgid "SUN4-8000-13.response"
53 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
54 msgid "SUN4-8000-13.impact"
55 msgstr "Loss of services provided by the device instances associated with this fault"
56 msgid "SUN4-8000-13.action"
57 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help illumos personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
59 # code: SUN4-8000-2H
60 # keys: fault.io.datapath
62 msgid "SUN4-8000-2H.type"
63 msgstr "Fault"
64 msgid "SUN4-8000-2H.severity"
65 msgstr "Critical"
66 msgid "SUN4-8000-2H.description"
67 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
68 msgid "SUN4-8000-2H.response"
69 msgstr "None"
70 msgid "SUN4-8000-2H.impact"
71 msgstr "None"
72 msgid "SUN4-8000-2H.action"
73 msgstr "None"
75 # code: SUN4-8000-3D
76 # keys: fault.io.hbus
78 msgid "SUN4-8000-3D.type"
79 msgstr "Fault"
80 msgid "SUN4-8000-3D.severity"
81 msgstr "Critical"
82 msgid "SUN4-8000-3D.description"
83 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
84 msgid "SUN4-8000-3D.response"
85 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
86 msgid "SUN4-8000-3D.impact"
87 msgstr "Loss of services provided by the device instances associated with this fault"
88 msgid "SUN4-8000-3D.action"
89 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
91 # code: SUN4-8000-4P
92 # keys: fault.io.fire.pciex.device
94 msgid "SUN4-8000-4P.type"
95 msgstr "Fault"
96 msgid "SUN4-8000-4P.severity"
97 msgstr "Critical"
98 msgid "SUN4-8000-4P.description"
99 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
100 msgid "SUN4-8000-4P.response"
101 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
102 msgid "SUN4-8000-4P.impact"
103 msgstr "Loss of services provided by the device instances associated with this fault"
104 msgid "SUN4-8000-4P.action"
105 msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
107 # code: SUN4-8000-5A
108 # keys: defect.io.fire.pciex.driver
110 msgid "SUN4-8000-5A.type"
111 msgstr "Defect"
112 msgid "SUN4-8000-5A.severity"
113 msgstr "Critical"
114 msgid "SUN4-8000-5A.description"
115 msgstr "A problem was detected in the PCI-Express subsystem software.\n  Refer to %s for more information."
116 msgid "SUN4-8000-5A.response"
117 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
118 msgid "SUN4-8000-5A.impact"
119 msgstr "Loss of services provided by the device instances associated with\nthis problem"
120 msgid "SUN4-8000-5A.action"
121 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
123 # code: SUN4-8000-6S
124 # keys: fault.io.datapath fault.io.fire.asic
126 msgid "SUN4-8000-6S.type"
127 msgstr "Fault"
128 msgid "SUN4-8000-6S.severity"
129 msgstr "Critical"
130 msgid "SUN4-8000-6S.description"
131 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
132 msgid "SUN4-8000-6S.response"
133 msgstr "None"
134 msgid "SUN4-8000-6S.impact"
135 msgstr "None"
136 msgid "SUN4-8000-6S.action"
137 msgstr "None"
139 # code: SUN4-8000-75
140 # keys: fault.io.fire.asic fault.io.fire.pciex.device
142 msgid "SUN4-8000-75.type"
143 msgstr "Fault"
144 msgid "SUN4-8000-75.severity"
145 msgstr "Critical"
146 msgid "SUN4-8000-75.description"
147 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
148 msgid "SUN4-8000-75.response"
149 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
150 msgid "SUN4-8000-75.impact"
151 msgstr "Loss of services provided by the device instances associated with this fault"
152 msgid "SUN4-8000-75.action"
153 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
155 # code: SUN4-8000-8E
156 # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
158 msgid "SUN4-8000-8E.type"
159 msgstr "Defect"
160 msgid "SUN4-8000-8E.severity"
161 msgstr "Critical"
162 msgid "SUN4-8000-8E.description"
163 msgstr "A problem was detected in the PCI-Express subsystem software.  Refer to %s for more information."
164 msgid "SUN4-8000-8E.response"
165 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
166 msgid "SUN4-8000-8E.impact"
167 msgstr "Loss of services provided by the device instances associated with this problem"
168 msgid "SUN4-8000-8E.action"
169 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
171 # code: SUN4-8000-9J
172 # keys: fault.io.fire.pci.device fault.io.fire.pciex.device
174 msgid "SUN4-8000-9J.type"
175 msgstr "Fault"
176 msgid "SUN4-8000-9J.severity"
177 msgstr "Critical"
178 msgid "SUN4-8000-9J.description"
179 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
180 msgid "SUN4-8000-9J.response"
181 msgstr "None"
182 msgid "SUN4-8000-9J.impact"
183 msgstr "None"
184 msgid "SUN4-8000-9J.action"
185 msgstr "None"
187 # code: SUN4-8000-A2
188 # keys: fault.io.fire.pci.device
190 msgid "SUN4-8000-A2.type"
191 msgstr "Fault"
192 msgid "SUN4-8000-A2.severity"
193 msgstr "Critical"
194 msgid "SUN4-8000-A2.description"
195 msgstr "A problem was detected in the PCI subsystem.\n  Refer to %s for more information."
196 msgid "SUN4-8000-A2.response"
197 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
198 msgid "SUN4-8000-A2.impact"
199 msgstr "Loss of services provided by the device instances associated with this fault"
200 msgid "SUN4-8000-A2.action"
201 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
203 # code: SUN4-8000-CX
204 # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
206 msgid "SUN4-8000-CX.type"
207 msgstr "Fault"
208 msgid "SUN4-8000-CX.severity"
209 msgstr "Critical"
210 msgid "SUN4-8000-CX.description"
211 msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details.  Refer to %s for more information."
212 msgid "SUN4-8000-CX.response"
213 msgstr "None"
214 msgid "SUN4-8000-CX.impact"
215 msgstr "None"
216 msgid "SUN4-8000-CX.action"
217 msgstr "None"
219 # code: SUN4-8000-D4
220 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
222 msgid "SUN4-8000-D4.type"
223 msgstr "Fault"
224 msgid "SUN4-8000-D4.severity"
225 msgstr "Critical"
226 msgid "SUN4-8000-D4.description"
227 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
228 msgid "SUN4-8000-D4.response"
229 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
230 msgid "SUN4-8000-D4.impact"
231 msgstr "Loss of services provided by the device instances associated with this fault"
232 msgid "SUN4-8000-D4.action"
233 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
235 # code: SUN4-8000-ER
236 # keys: fault.io.fire.asic fault.io.fire.pci.device
238 msgid "SUN4-8000-ER.type"
239 msgstr "Fault"
240 msgid "SUN4-8000-ER.severity"
241 msgstr "Critical"
242 msgid "SUN4-8000-ER.description"
243 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
244 msgid "SUN4-8000-ER.response"
245 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
246 msgid "SUN4-8000-ER.impact"
247 msgstr "Loss of services provided by the device instances associated with this fault"
248 msgid "SUN4-8000-ER.action"
249 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
251 # code: SUN4-8000-FC
252 # keys: fault.io.fire.hbus
254 msgid "SUN4-8000-FC.type"
255 msgstr "Fault"
256 msgid "SUN4-8000-FC.severity"
257 msgstr "Major"
258 msgid "SUN4-8000-FC.description"
259 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
260 msgid "SUN4-8000-FC.response"
261 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
262 msgid "SUN4-8000-FC.impact"
263 msgstr "Loss of services provided by the device instances associated with this fault"
264 msgid "SUN4-8000-FC.action"
265 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
267 # code: SUN4-8000-GQ
268 # keys: fault.io.fire.datapath fault.io.fire.hbus
270 msgid "SUN4-8000-GQ.type"
271 msgstr "Fault"
272 msgid "SUN4-8000-GQ.severity"
273 msgstr "Critical"
274 msgid "SUN4-8000-GQ.description"
275 msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n  Refer to %s for more information."
276 msgid "SUN4-8000-GQ.response"
277 msgstr "One or more device instances may be disabled\n"
278 msgid "SUN4-8000-GQ.impact"
279 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
280 msgid "SUN4-8000-GQ.action"
281 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
283 # code: SUN4-8000-HD
284 # keys: fault.io.fire.hb.sw-config
286 msgid "SUN4-8000-HD.type"
287 msgstr "Fault"
288 msgid "SUN4-8000-HD.severity"
289 msgstr "Critical"
290 msgid "SUN4-8000-HD.description"
291 msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
292 msgid "SUN4-8000-HD.response"
293 msgstr "One or more device instances may be disabled\n"
294 msgid "SUN4-8000-HD.impact"
295 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
296 msgid "SUN4-8000-HD.action"
297 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
299 # code: SUN4-8000-JH
300 # keys: fault.io.fire.dmc.sw-algorithm
302 msgid "SUN4-8000-JH.type"
303 msgstr "Fault"
304 msgid "SUN4-8000-JH.severity"
305 msgstr "Critical"
306 msgid "SUN4-8000-JH.description"
307 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
308 msgid "SUN4-8000-JH.response"
309 msgstr "One or more device instances may be disabled\n"
310 msgid "SUN4-8000-JH.impact"
311 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
312 msgid "SUN4-8000-JH.action"
313 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
315 # code: SUN4-8000-K3
316 # keys: fault.io.fire.dmc.sw-state
318 msgid "SUN4-8000-K3.type"
319 msgstr "Fault"
320 msgid "SUN4-8000-K3.severity"
321 msgstr "Critical"
322 msgid "SUN4-8000-K3.description"
323 msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
324 msgid "SUN4-8000-K3.response"
325 msgstr "One or more device instances may be disabled\n"
326 msgid "SUN4-8000-K3.impact"
327 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
328 msgid "SUN4-8000-K3.action"
329 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
331 # code: SUN4-8000-LY
332 # keys: fault.io.fire.pec.sw-algorithm
334 msgid "SUN4-8000-LY.type"
335 msgstr "Fault"
336 msgid "SUN4-8000-LY.severity"
337 msgstr "Critical"
338 msgid "SUN4-8000-LY.description"
339 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
340 msgid "SUN4-8000-LY.response"
341 msgstr "One or more device instances may be disabled\n"
342 msgid "SUN4-8000-LY.impact"
343 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
344 msgid "SUN4-8000-LY.action"
345 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"