dmake: do not set MAKEFLAGS=k
[unleashed/tickless.git] / usr / src / cmd / fm / dicts / SUNOS.po
blobcaccdfc1b3df9d2d03c61ba1d454ef82784f44c4
2 # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
4 # CDDL HEADER START
6 # The contents of this file are subject to the terms of the
7 # Common Development and Distribution License (the "License").
8 # You may not use this file except in compliance with the License.
10 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11 # or http://www.opensolaris.org/os/licensing.
12 # See the License for the specific language governing permissions
13 # and limitations under the License.
15 # When distributing Covered Code, include this CDDL HEADER in each
16 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17 # If applicable, add the following below this CDDL HEADER, with the
18 # fields enclosed by brackets "[]" replaced with your own identifying
19 # information: Portions Copyright [yyyy] [name of copyright owner]
21 # CDDL HEADER END
24 # DO NOT EDIT -- this file is generated by the Event Registry.
27 # code: SUNOS-8000-0G
28 # keys: ereport.sunos.unix.fm_panic
30 msgid "SUNOS-8000-0G.type"
31 msgstr "Error"
32 msgid "SUNOS-8000-0G.severity"
33 msgstr "Major"
34 msgid "SUNOS-8000-0G.description"
35 msgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
36 msgid "SUNOS-8000-0G.response"
37 msgstr "illumos will attempt to save and diagnose the error telemetry"
38 msgid "SUNOS-8000-0G.impact"
39 msgstr "The system will sync files, save a crash dump if needed, and reboot"
40 msgid "SUNOS-8000-0G.action"
41 msgstr "Save the error summary below in case telemetry cannot be saved"
43 # code: SUNOS-8000-1L
44 # keys: defect.sunos.eft.undiagnosable_problem
46 msgid "SUNOS-8000-1L.type"
47 msgstr "Defect"
48 msgid "SUNOS-8000-1L.severity"
49 msgstr "Minor"
50 msgid "SUNOS-8000-1L.description"
51 msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
52 msgid "SUNOS-8000-1L.response"
53 msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
54 msgid "SUNOS-8000-1L.impact"
55 msgstr "Automated diagnosis and response for these events will not occur."
56 msgid "SUNOS-8000-1L.action"
57 msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
59 # code: SUNOS-8000-20
60 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
62 msgid "SUNOS-8000-20.type"
63 msgstr "Fault"
64 msgid "SUNOS-8000-20.severity"
65 msgstr "Critical"
66 msgid "SUNOS-8000-20.description"
67 msgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
68 msgid "SUNOS-8000-20.response"
69 msgstr "One or more of device instances may be disabled"
70 msgid "SUNOS-8000-20.impact"
71 msgstr "Loss of services provided by the device instances associated with this fault"
72 msgid "SUNOS-8000-20.action"
73 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
75 # code: SUNOS-8000-3V
76 # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
78 msgid "SUNOS-8000-3V.type"
79 msgstr "Fault"
80 msgid "SUNOS-8000-3V.severity"
81 msgstr "Critical"
82 msgid "SUNOS-8000-3V.description"
83 msgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
84 msgid "SUNOS-8000-3V.response"
85 msgstr "One or more of device instances may be disabled"
86 msgid "SUNOS-8000-3V.impact"
87 msgstr "Loss of services provided by the device instances associated with this fault"
88 msgid "SUNOS-8000-3V.action"
89 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
91 # code: SUNOS-8000-46
92 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
94 msgid "SUNOS-8000-46.type"
95 msgstr "Fault"
96 msgid "SUNOS-8000-46.severity"
97 msgstr "Critical"
98 msgid "SUNOS-8000-46.description"
99 msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
100 msgid "SUNOS-8000-46.response"
101 msgstr "One or more of device instances may be disabled"
102 msgid "SUNOS-8000-46.impact"
103 msgstr "Loss of services provided by the device instances associated with this fault"
104 msgid "SUNOS-8000-46.action"
105 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
107 # code: SUNOS-8000-5T
108 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
110 msgid "SUNOS-8000-5T.type"
111 msgstr "Fault"
112 msgid "SUNOS-8000-5T.severity"
113 msgstr "Critical"
114 msgid "SUNOS-8000-5T.description"
115 msgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
116 msgid "SUNOS-8000-5T.response"
117 msgstr "One or more of device instances may be disabled"
118 msgid "SUNOS-8000-5T.impact"
119 msgstr "Loss of services provided by the device instances associated with this fault"
120 msgid "SUNOS-8000-5T.action"
121 msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
123 # code: SUNOS-8000-69
124 # keys: defect.Deprecated fault.io.pci.device
126 msgid "SUNOS-8000-69.type"
127 msgstr "Fault"
128 msgid "SUNOS-8000-69.severity"
129 msgstr "Critical"
130 msgid "SUNOS-8000-69.description"
131 msgstr "A problem was detected for a PCI controller  Refer to %s for more information."
132 msgid "SUNOS-8000-69.response"
133 msgstr "One or more of device instances may be disabled"
134 msgid "SUNOS-8000-69.impact"
135 msgstr "Loss of services provided by the device instances associated with this fault."
136 msgid "SUNOS-8000-69.action"
137 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
139 # code: SUNOS-8000-7N
140 # keys: defect.Deprecated fault.io.pci.bus
142 msgid "SUNOS-8000-7N.type"
143 msgstr "Fault"
144 msgid "SUNOS-8000-7N.severity"
145 msgstr "Critical"
146 msgid "SUNOS-8000-7N.description"
147 msgstr "A problem was detected for a PCI bus  Refer to %s for more information."
148 msgid "SUNOS-8000-7N.response"
149 msgstr "One or more of device instances may be disabled"
150 msgid "SUNOS-8000-7N.impact"
151 msgstr "Loss of services provided by the device instances associated with this fault."
152 msgid "SUNOS-8000-7N.action"
153 msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
155 # code: SUNOS-8000-8W
156 # keys: defect.Deprecated defect.io.pci.driver
158 msgid "SUNOS-8000-8W.type"
159 msgstr "Fault"
160 msgid "SUNOS-8000-8W.severity"
161 msgstr "Critical"
162 msgid "SUNOS-8000-8W.description"
163 msgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
164 msgid "SUNOS-8000-8W.response"
165 msgstr "One or more of device instances may be disabled"
166 msgid "SUNOS-8000-8W.impact"
167 msgstr "Loss of services provided by the device instances associated with this fault."
168 msgid "SUNOS-8000-8W.action"
169 msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
171 # code: SUNOS-8000-91
172 # keys: defect.sunos.zones.upgrade
174 msgid "SUNOS-8000-91.type"
175 msgstr "Defect"
176 msgid "SUNOS-8000-91.severity"
177 msgstr "Minor"
178 msgid "SUNOS-8000-91.description"
179 msgstr "\n      The illumos system or boot environment that is being upgraded\n has non-global zones installed.  The current version of Live\n  Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n        Refer to %s for more information."
180 msgid "SUNOS-8000-91.response"
181 msgstr "The upgrade procedure has been terminated."
182 msgid "SUNOS-8000-91.impact"
183 msgstr "The illumos system or boot environment is not upgraded."
184 msgid "SUNOS-8000-91.action"
185 msgstr "\n      Evaluate each of the choices below and select the one that is\n best for your needs.  Contact your illumos distribution team for support.\n     "
187 # code: SUNOS-8000-AK
188 # keys: ereport.sunos.boot.upgrade.menu_lst
190 msgid "SUNOS-8000-AK.type"
191 msgstr "Error"
192 msgid "SUNOS-8000-AK.severity"
193 msgstr "Critical"
194 msgid "SUNOS-8000-AK.description"
195 msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
196 msgid "SUNOS-8000-AK.response"
197 msgstr "No automated response."
198 msgid "SUNOS-8000-AK.impact"
199 msgstr "Future reboots could fail until this problem is corrected."
200 msgid "SUNOS-8000-AK.action"
201 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
203 # code: SUNOS-8000-CF
204 # keys: ereport.sunos.boot.upgrade.menu_lst_bfu
206 msgid "SUNOS-8000-CF.type"
207 msgstr "Error"
208 msgid "SUNOS-8000-CF.severity"
209 msgstr "Critical"
210 msgid "SUNOS-8000-CF.description"
211 msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
212 msgid "SUNOS-8000-CF.response"
213 msgstr "No automated response."
214 msgid "SUNOS-8000-CF.impact"
215 msgstr "Future reboots could fail until this problem is corrected."
216 msgid "SUNOS-8000-CF.action"
217 msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
219 # code: SUNOS-8000-DM
220 # keys: defect.sunos.smf.svc.maintenance
222 msgid "SUNOS-8000-DM.type"
223 msgstr "Defect"
224 msgid "SUNOS-8000-DM.severity"
225 msgstr "Major"
226 msgid "SUNOS-8000-DM.description"
227 msgstr "A service failed and could not be restarted.  Refer to %s for more information."
228 msgid "SUNOS-8000-DM.response"
229 msgstr "The service has been placed into the maintenance state."
230 msgid "SUNOS-8000-DM.impact"
231 msgstr "The service is unavailable."
232 msgid "SUNOS-8000-DM.action"
233 msgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any."
235 # code: SUNOS-8000-E8
236 # keys: defect.sunos.eft.undiag.checkpoint
238 msgid "SUNOS-8000-E8.type"
239 msgstr "Defect"
240 msgid "SUNOS-8000-E8.severity"
241 msgstr "Minor"
242 msgid "SUNOS-8000-E8.description"
243 msgstr "The diagnosis engine encountered an error while resuming diagnosis.  Refer to %s for more information."
244 msgid "SUNOS-8000-E8.response"
245 msgstr "Error reports have been logged for examination by your illumos distribution team."
246 msgid "SUNOS-8000-E8.impact"
247 msgstr "Automated diagnosis and response for these events will not occur."
248 msgid "SUNOS-8000-E8.action"
249 msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager."
251 # code: SUNOS-8000-FU
252 # keys: defect.sunos.eft.undiag.fme
254 msgid "SUNOS-8000-FU.type"
255 msgstr "Defect"
256 msgid "SUNOS-8000-FU.severity"
257 msgstr "Major"
258 msgid "SUNOS-8000-FU.description"
259 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
260 msgid "SUNOS-8000-FU.response"
261 msgstr "Error reports have been logged for examination by your illumos distribution team."
262 msgid "SUNOS-8000-FU.impact"
263 msgstr "Automated diagnosis and response for these events will not occur."
264 msgid "SUNOS-8000-FU.action"
265 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
267 # code: SUNOS-8000-G7
268 # keys: defect.sunos.eft.undiag.limit
270 msgid "SUNOS-8000-G7.type"
271 msgstr "Defect"
272 msgid "SUNOS-8000-G7.severity"
273 msgstr "Minor"
274 msgid "SUNOS-8000-G7.description"
275 msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis.  Refer to %s for more information."
276 msgid "SUNOS-8000-G7.response"
277 msgstr "Error reports have been logged for examination by your illumos distribution team."
278 msgid "SUNOS-8000-G7.impact"
279 msgstr "Automated diagnosis and response for these events will not occur."
280 msgid "SUNOS-8000-G7.action"
281 msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
283 # code: SUNOS-8000-HV
284 # keys: defect.sunos.eft.undiag.unknown
286 msgid "SUNOS-8000-HV.type"
287 msgstr "Defect"
288 msgid "SUNOS-8000-HV.severity"
289 msgstr "Minor"
290 msgid "SUNOS-8000-HV.description"
291 msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
292 msgid "SUNOS-8000-HV.response"
293 msgstr "Error reports have been logged for examination by your illumos distribution team."
294 msgid "SUNOS-8000-HV.impact"
295 msgstr "Automated diagnosis and response for these events will not occur."
296 msgid "SUNOS-8000-HV.action"
297 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
299 # code: SUNOS-8000-J0
300 # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry
302 msgid "SUNOS-8000-J0.type"
303 msgstr "Fault"
304 msgid "SUNOS-8000-J0.severity"
305 msgstr "Major"
306 msgid "SUNOS-8000-J0.description"
307 msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n  Refer to %s for more information.  Refer to %s for more information."
308 msgid "SUNOS-8000-J0.response"
309 msgstr "Error reports have been logged for examination by your illumos distribution team.\n"
310 msgid "SUNOS-8000-J0.impact"
311 msgstr "Automated diagnosis and response for these events will not occur.\n"
312 msgid "SUNOS-8000-J0.action"
313 msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n"
315 # code: SUNOS-8000-KL
316 # keys: defect.sunos.kernel.panic
318 msgid "SUNOS-8000-KL.type"
319 msgstr "Defect"
320 msgid "SUNOS-8000-KL.severity"
321 msgstr "Major"
322 msgid "SUNOS-8000-KL.description"
323 msgstr "The system has rebooted after a kernel panic.  Refer to %s for more information."
324 msgid "SUNOS-8000-KL.response"
325 msgstr "The failed system image was dumped to the dump device.  If savecore is enabled (see dumpadm(1M)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>."
326 msgid "SUNOS-8000-KL.impact"
327 msgstr "There may be some performance impact while the panic is copied to the savecore directory.  Disk space usage by panics can be substantial."
328 msgid "SUNOS-8000-KL.action"
329 msgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail.  Please refer to the knowledge article for additional information."