1 /*
2 * include/linux/input/adxl34x.h
4 * Digital Accelerometer characteristics are highly application specific
5 * and may vary between boards and models. The platform_data for the
6 * device's "struct device" holds this information.
8 * Copyright 2009 Analog Devices Inc.
10 * Licensed under the GPL-2 or later.
13 #ifndef __LINUX_INPUT_ADXL34X_H__
14 #define __LINUX_INPUT_ADXL34X_H__
16 struct adxl34x_platform_data {
19 * X,Y,Z Axis Offset:
20 * offer user offset adjustments in twoscompliment
21 * form with a scale factor of 15.6 mg/LSB (i.e. 0x7F = +2 g)
24 s8 x_axis_offset;
25 s8 y_axis_offset;
26 s8 z_axis_offset;
29 * TAP_X/Y/Z Enable: Setting TAP_X, Y, or Z Enable enables X,
30 * Y, or Z participation in Tap detection. A '0' excludes the
31 * selected axis from participation in Tap detection.
32 * Setting the SUPPRESS bit suppresses Double Tap detection if
33 * acceleration greater than tap_threshold is present during the
34 * tap_latency period, i.e. after the first tap but before the
35 * opening of the second tap window.
38 #define ADXL_SUPPRESS (1 << 3)
39 #define ADXL_TAP_X_EN (1 << 2)
40 #define ADXL_TAP_Y_EN (1 << 1)
41 #define ADXL_TAP_Z_EN (1 << 0)
43 u8 tap_axis_control;
46 * tap_threshold:
47 * holds the threshold value for tap detection/interrupts.
48 * The data format is unsigned. The scale factor is 62.5 mg/LSB
49 * (i.e. 0xFF = +16 g). A zero value may result in undesirable
50 * behavior if Tap/Double Tap is enabled.
53 u8 tap_threshold;
56 * tap_duration:
57 * is an unsigned time value representing the maximum
58 * time that an event must be above the tap_threshold threshold
59 * to qualify as a tap event. The scale factor is 625 us/LSB. A zero
60 * value will prevent Tap/Double Tap functions from working.
63 u8 tap_duration;
66 * tap_latency:
67 * is an unsigned time value representing the wait time
68 * from the detection of a tap event to the opening of the time
69 * window tap_window for a possible second tap event. The scale
70 * factor is 1.25 ms/LSB. A zero value will disable the Double Tap
71 * function.
74 u8 tap_latency;
77 * tap_window:
78 * is an unsigned time value representing the amount
79 * of time after the expiration of tap_latency during which a second
80 * tap can begin. The scale factor is 1.25 ms/LSB. A zero value will
81 * disable the Double Tap function.
84 u8 tap_window;
87 * act_axis_control:
88 * X/Y/Z Enable: A '1' enables X, Y, or Z participation in activity
89 * or inactivity detection. A '0' excludes the selected axis from
90 * participation. If all of the axes are excluded, the function is
91 * disabled.
92 * AC/DC: A '0' = DC coupled operation and a '1' = AC coupled
93 * operation. In DC coupled operation, the current acceleration is
94 * compared with activity_threshold and inactivity_threshold directly
95 * to determine whether activity or inactivity is detected. In AC
96 * coupled operation for activity detection, the acceleration value
97 * at the start of activity detection is taken as a reference value.
98 * New samples of acceleration are then compared to this
99 * reference value and if the magnitude of the difference exceeds
100 * activity_threshold the device will trigger an activity interrupt. In
101 * AC coupled operation for inactivity detection, a reference value
102 * is used again for comparison and is updated whenever the
103 * device exceeds the inactivity threshold. Once the reference
104 * value is selected, the device compares the magnitude of the
105 * difference between the reference value and the current
106 * acceleration with inactivity_threshold. If the difference is below
107 * inactivity_threshold for a total of inactivity_time, the device is
108 * considered inactive and the inactivity interrupt is triggered.
111 #define ADXL_ACT_ACDC (1 << 7)
112 #define ADXL_ACT_X_EN (1 << 6)
113 #define ADXL_ACT_Y_EN (1 << 5)
114 #define ADXL_ACT_Z_EN (1 << 4)
115 #define ADXL_INACT_ACDC (1 << 3)
116 #define ADXL_INACT_X_EN (1 << 2)
117 #define ADXL_INACT_Y_EN (1 << 1)
118 #define ADXL_INACT_Z_EN (1 << 0)
120 u8 act_axis_control;
123 * activity_threshold:
124 * holds the threshold value for activity detection.
125 * The data format is unsigned. The scale factor is
126 * 62.5 mg/LSB. A zero value may result in undesirable behavior if
127 * Activity interrupt is enabled.
130 u8 activity_threshold;
133 * inactivity_threshold:
134 * holds the threshold value for inactivity
135 * detection. The data format is unsigned. The scale
136 * factor is 62.5 mg/LSB. A zero value may result in undesirable
137 * behavior if Inactivity interrupt is enabled.
140 u8 inactivity_threshold;
143 * inactivity_time:
144 * is an unsigned time value representing the
145 * amount of time that acceleration must be below the value in
146 * inactivity_threshold for inactivity to be declared. The scale factor
147 * is 1 second/LSB. Unlike the other interrupt functions, which
148 * operate on unfiltered data, the inactivity function operates on the
149 * filtered output data. At least one output sample must be
150 * generated for the inactivity interrupt to be triggered. This will
151 * result in the function appearing un-responsive if the
152 * inactivity_time register is set with a value less than the time
153 * constant of the Output Data Rate. A zero value will result in an
154 * interrupt when the output data is below inactivity_threshold.
157 u8 inactivity_time;
160 * free_fall_threshold:
161 * holds the threshold value for Free-Fall detection.
162 * The data format is unsigned. The root-sum-square(RSS) value
163 * of all axes is calculated and compared to the value in
164 * free_fall_threshold to determine if a free fall event may be
165 * occurring. The scale factor is 62.5 mg/LSB. A zero value may
166 * result in undesirable behavior if Free-Fall interrupt is
167 * enabled. Values between 300 and 600 mg (0x05 to 0x09) are
168 * recommended.
171 u8 free_fall_threshold;
174 * free_fall_time:
175 * is an unsigned time value representing the minimum
176 * time that the RSS value of all axes must be less than
177 * free_fall_threshold to generate a Free-Fall interrupt. The
178 * scale factor is 5 ms/LSB. A zero value may result in
179 * undesirable behavior if Free-Fall interrupt is enabled.
180 * Values between 100 to 350 ms (0x14 to 0x46) are recommended.
183 u8 free_fall_time;
186 * data_rate:
187 * Selects device bandwidth and output data rate.
188 * RATE = 3200 Hz / (2^(15 - x)). Default value is 0x0A, or 100 Hz
189 * Output Data Rate. An Output Data Rate should be selected that
190 * is appropriate for the communication protocol and frequency
191 * selected. Selecting too high of an Output Data Rate with a low
192 * communication speed will result in samples being discarded.
195 u8 data_rate;
198 * data_range:
199 * FULL_RES: When this bit is set with the device is
200 * in Full-Resolution Mode, where the output resolution increases
201 * with RANGE to maintain a 4 mg/LSB scale factor. When this
202 * bit is cleared the device is in 10-bit Mode and RANGE determine the
203 * maximum g-Range and scale factor.
206 #define ADXL_FULL_RES (1 << 3)
207 #define ADXL_RANGE_PM_2g 0
208 #define ADXL_RANGE_PM_4g 1
209 #define ADXL_RANGE_PM_8g 2
210 #define ADXL_RANGE_PM_16g 3
212 u8 data_range;
215 * low_power_mode:
216 * A '0' = Normal operation and a '1' = Reduced
217 * power operation with somewhat higher noise.
220 u8 low_power_mode;
223 * power_mode:
224 * LINK: A '1' with both the activity and inactivity functions
225 * enabled will delay the start of the activity function until
226 * inactivity is detected. Once activity is detected, inactivity
227 * detection will begin and prevent the detection of activity. This
228 * bit serially links the activity and inactivity functions. When '0'
229 * the inactivity and activity functions are concurrent. Additional
230 * information can be found in the ADXL34x datasheet's Application
231 * section under Link Mode.
232 * AUTO_SLEEP: A '1' sets the ADXL34x to switch to Sleep Mode
233 * when inactivity (acceleration has been below inactivity_threshold
234 * for at least inactivity_time) is detected and the LINK bit is set.
235 * A '0' disables automatic switching to Sleep Mode. See the
236 * Sleep Bit section of the ADXL34x datasheet for more information.
239 #define ADXL_LINK (1 << 5)
240 #define ADXL_AUTO_SLEEP (1 << 4)
242 u8 power_mode;
245 * fifo_mode:
246 * BYPASS The FIFO is bypassed
247 * FIFO FIFO collects up to 32 values then stops collecting data
248 * STREAM FIFO holds the last 32 data values. Once full, the FIFO's
249 * oldest data is lost as it is replaced with newer data
251 * DEFAULT should be ADXL_FIFO_STREAM
254 #define ADXL_FIFO_BYPASS 0
255 #define ADXL_FIFO_FIFO 1
256 #define ADXL_FIFO_STREAM 2
258 u8 fifo_mode;
261 * watermark:
262 * The Watermark feature can be used to reduce the interrupt load
263 * of the system. The FIFO fills up to the value stored in watermark
264 * [1..32] and then generates an interrupt.
265 * A '0' disables the watermark feature.
268 u8 watermark;
271 * When acceleration measurements are received from the ADXL34x
272 * events are sent to the event subsystem. The following settings
273 * select the event type and event code for new x, y and z axis data
274 * respectively.
276 u32 ev_type; /* EV_ABS or EV_REL */
278 u32 ev_code_x; /* ABS_X,Y,Z or REL_X,Y,Z */
279 u32 ev_code_y; /* ABS_X,Y,Z or REL_X,Y,Z */
280 u32 ev_code_z; /* ABS_X,Y,Z or REL_X,Y,Z */
283 * A valid BTN or KEY Code; use tap_axis_control to disable
284 * event reporting
287 u32 ev_code_tap[3]; /* EV_KEY {X-Axis, Y-Axis, Z-Axis} */
290 * A valid BTN or KEY Code for Free-Fall or Activity enables
291 * input event reporting. A '0' disables the Free-Fall or
292 * Activity reporting.
295 u32 ev_code_ff; /* EV_KEY */
296 u32 ev_code_act_inactivity; /* EV_KEY */
299 * Use ADXL34x INT2 pin instead of INT1 pin for interrupt output
301 u8 use_int2;
304 * ADXL346 only ORIENTATION SENSING feature
305 * The orientation function of the ADXL346 reports both 2-D and
306 * 3-D orientation concurrently.
309 #define ADXL_EN_ORIENTATION_2D 1
310 #define ADXL_EN_ORIENTATION_3D 2
311 #define ADXL_EN_ORIENTATION_2D_3D 3
313 u8 orientation_enable;
316 * The width of the deadzone region between two or more
317 * orientation positions is determined by setting the Deadzone
318 * value. The deadzone region size can be specified with a
319 * resolution of 3.6deg. The deadzone angle represents the total
320 * angle where the orientation is considered invalid.
323 #define ADXL_DEADZONE_ANGLE_0p0 0 /* !!!0.0 [deg] */
324 #define ADXL_DEADZONE_ANGLE_3p6 1 /* 3.6 [deg] */
325 #define ADXL_DEADZONE_ANGLE_7p2 2 /* 7.2 [deg] */
326 #define ADXL_DEADZONE_ANGLE_10p8 3 /* 10.8 [deg] */
327 #define ADXL_DEADZONE_ANGLE_14p4 4 /* 14.4 [deg] */
328 #define ADXL_DEADZONE_ANGLE_18p0 5 /* 18.0 [deg] */
329 #define ADXL_DEADZONE_ANGLE_21p6 6 /* 21.6 [deg] */
330 #define ADXL_DEADZONE_ANGLE_25p2 7 /* 25.2 [deg] */
332 u8 deadzone_angle;
335 * To eliminate most human motion such as walking or shaking,
336 * a Divisor value should be selected to effectively limit the
337 * orientation bandwidth. Set the depth of the filter used to
338 * low-pass filter the measured acceleration for stable
339 * orientation sensing
342 #define ADXL_LP_FILTER_DIVISOR_2 0
343 #define ADXL_LP_FILTER_DIVISOR_4 1
344 #define ADXL_LP_FILTER_DIVISOR_8 2
345 #define ADXL_LP_FILTER_DIVISOR_16 3
346 #define ADXL_LP_FILTER_DIVISOR_32 4
347 #define ADXL_LP_FILTER_DIVISOR_64 5
348 #define ADXL_LP_FILTER_DIVISOR_128 6
349 #define ADXL_LP_FILTER_DIVISOR_256 7
351 u8 divisor_length;
353 u32 ev_codes_orient_2d[4]; /* EV_KEY {+X, -X, +Y, -Y} */
354 u32 ev_codes_orient_3d[6]; /* EV_KEY {+Z, +Y, +X, -X, -Y, -Z} */
356 #endif