Staging: Merge branch 'tidspbridge-for-2.6.39' of git://dev.omapzoom.org/pub/scm...
[zen-stable.git] / net / tipc / Kconfig
blob0436927369f3a5685346681f4a312a9fbe36130c
2 # TIPC configuration
5 menuconfig TIPC
6         tristate "The TIPC Protocol (EXPERIMENTAL)"
7         depends on INET && EXPERIMENTAL
8         ---help---
9           The Transparent Inter Process Communication (TIPC) protocol is
10           specially designed for intra cluster communication. This protocol
11           originates from Ericsson where it has been used in carrier grade
12           cluster applications for many years.
14           For more information about TIPC, see http://tipc.sourceforge.net.
16           This protocol support is also available as a module ( = code which
17           can be inserted in and removed from the running kernel whenever you
18           want). The module will be called tipc. If you want to compile it
19           as a module, say M here and read <file:Documentation/kbuild/modules.txt>.
21           If in doubt, say N.
23 if TIPC
25 config TIPC_ADVANCED
26         bool "Advanced TIPC configuration"
27         default n
28         help
29           Saying Y here will open some advanced configuration for TIPC.
30           Most users do not need to bother; if unsure, just say N.
32 config TIPC_NODES
33         int "Maximum number of nodes in a cluster"
34         depends on TIPC_ADVANCED
35         range 8 2047
36         default "255"
37         help
38           Specifies how many nodes can be supported in a TIPC cluster.
39           Can range from 8 to 2047 nodes; default is 255.
41           Setting this to a smaller value saves some memory;
42           setting it to higher allows for more nodes.
44 config TIPC_PORTS
45         int "Maximum number of ports in a node"
46         depends on TIPC_ADVANCED
47         range 127 65535
48         default "8191"
49         help
50           Specifies how many ports can be supported by a node.
51           Can range from 127 to 65535 ports; default is 8191.
53           Setting this to a smaller value saves some memory,
54           setting it to higher allows for more ports.
56 config TIPC_LOG
57         int "Size of log buffer"
58         depends on TIPC_ADVANCED
59         range 0 32768
60         default "0"
61         help
62           Size (in bytes) of TIPC's internal log buffer, which records the
63           occurrence of significant events.  Can range from 0 to 32768 bytes;
64           default is 0.
66           There is no need to enable the log buffer unless the node will be
67           managed remotely via TIPC.
69 config TIPC_DEBUG
70         bool "Enable debugging support"
71         default n
72         help
73           Saying Y here enables TIPC debugging capabilities used by developers.
74           Most users do not need to bother; if unsure, just say N.
76           Enabling debugging support causes TIPC to display data about its
77           internal state when certain abnormal conditions occur. It also
78           makes it easy for developers to capture additional information of
79           interest using the dbg() or msg_dbg() macros.
81 endif # TIPC