1 Kernel driver max34440
2 ======================
4 Supported chips:
5   * Maxim MAX34440
6     Prefixes: 'max34440'
7     Addresses scanned: -
8     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf
9   * Maxim MAX34441
10     PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller
11     Prefixes: 'max34441'
12     Addresses scanned: -
13     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf
15 Author: Guenter Roeck <guenter.roeck@ericsson.com>
18 Description
19 -----------
21 This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel
22 Power-Supply Manager and MAX34441 PMBus 5-Channel Power-Supply Manager
23 and Intelligent Fan Controller.
25 The driver is a client driver to the core PMBus driver. Please see
26 Documentation/hwmon/pmbus for details on PMBus client drivers.
29 Usage Notes
30 -----------
32 This driver does not auto-detect devices. You will have to instantiate the
33 devices explicitly. Please see Documentation/i2c/instantiating-devices for
34 details.
37 Platform data support
38 ---------------------
40 The driver supports standard PMBus driver platform data.
43 Sysfs entries
44 -------------
46 The following attributes are supported. Limits are read-write; all other
47 attributes are read-only.
49 in[1-6]_label           "vout[1-6]".
50 in[1-6]_input           Measured voltage. From READ_VOUT register.
51 in[1-6]_min             Minumum Voltage. From VOUT_UV_WARN_LIMIT register.
52 in[1-6]_max             Maximum voltage. From VOUT_OV_WARN_LIMIT register.
53 in[1-6]_lcrit           Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register.
54 in[1-6]_crit            Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
55 in[1-6]_min_alarm       Voltage low alarm. From VOLTAGE_UV_WARNING status.
56 in[1-6]_max_alarm       Voltage high alarm. From VOLTAGE_OV_WARNING status.
57 in[1-6]_lcrit_alarm     Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
58 in[1-6]_crit_alarm      Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
59 in[1-6]_highest         Historical maximum voltage.
60 in[1-6]_reset_history   Write any value to reset history.
62 curr[1-6]_label         "iout[1-6]".
63 curr[1-6]_input         Measured current. From READ_IOUT register.
64 curr[1-6]_max           Maximum current. From IOUT_OC_WARN_LIMIT register.
65 curr[1-6]_crit          Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
66 curr[1-6]_max_alarm     Current high alarm. From IOUT_OC_WARNING status.
67 curr[1-6]_crit_alarm    Current critical high alarm. From IOUT_OC_FAULT status.
68 curr[1-6]_highest       Historical maximum current.
69 curr[1-6]_reset_history Write any value to reset history.
71                         in6 and curr6 attributes only exist for MAX34440.
73 temp[1-8]_input         Measured temperatures. From READ_TEMPERATURE_1 register.
74                         temp1 is the chip's internal temperature. temp2..temp5
75                         are remote I2C temperature sensors. For MAX34441, temp6
76                         is a remote thermal-diode sensor. For MAX34440, temp6..8
77                         are remote I2C temperature sensors.
78 temp[1-8]_max           Maximum temperature. From OT_WARN_LIMIT register.
79 temp[1-8]_crit          Critical high temperature. From OT_FAULT_LIMIT register.
80 temp[1-8]_max_alarm     Temperature high alarm.
81 temp[1-8]_crit_alarm    Temperature critical high alarm.
82 temp[1-8]_highest       Historical maximum temperature.
83 temp[1-8]_reset_history Write any value to reset history.
85                         temp7 and temp8 attributes only exist for MAX34440.