1 What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_switch_en
3 Contact: linux-iio@vger.kernel.org
5 Writing 1 enables the cell balance output switch corresponding
6 to input Y. Writing 0 disables it. If the inY-inZ_balance_timer
7 is set to a none zero value, the corresponding switch will
8 enable for the programmed amount of time, before it
9 automatically disables.
11 What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_timer
13 Contact: linux-iio@vger.kernel.org
15 The inY-inZ_balance_timer file allows the user to program
16 individual times for each cell balance output. The AD7280A
17 allows the user to set the timer to a value from 0 minutes to
18 36.9 minutes. The resolution of the timer is 71.5 sec.
19 The value written is the on-time in milliseconds. When the
20 timer value is set 0, the timer is disabled. The cell balance
21 outputs are controlled only by inY-inZ_balance_switch_en.