Staging: hv: mousevsc: Cleanup and properly implement reportdesc_callback()
[zen-stable.git] / drivers / md / Kconfig
blobf75a66e7d312a8e1efed3d2db37ba1c554785e94
2 # Block device driver configuration
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         help
9           Support multiple physical spindles through a single logical device.
10           Required for RAID and logical volume management.
12 if MD
14 config BLK_DEV_MD
15         tristate "RAID support"
16         ---help---
17           This driver lets you combine several hard disk partitions into one
18           logical block device. This can be used to simply append one
19           partition to another one or to combine several redundant hard disks
20           into a RAID1/4/5 device so as to provide protection against hard
21           disk failures. This is called "Software RAID" since the combining of
22           the partitions is done by the kernel. "Hardware RAID" means that the
23           combining is done by a dedicated controller; if you have such a
24           controller, you do not need to say Y here.
26           More information about Software RAID on Linux is contained in the
27           Software RAID mini-HOWTO, available from
28           <http://www.tldp.org/docs.html#howto>. There you will also learn
29           where to get the supporting user space utilities raidtools.
31           If unsure, say N.
33 config MD_AUTODETECT
34         bool "Autodetect RAID arrays during kernel boot"
35         depends on BLK_DEV_MD=y
36         default y
37         ---help---
38           If you say Y here, then the kernel will try to autodetect raid
39           arrays as part of its boot process. 
41           If you don't use raid and say Y, this autodetection can cause 
42           a several-second delay in the boot time due to various
43           synchronisation steps that are part of this step.
45           If unsure, say Y.
47 config MD_LINEAR
48         tristate "Linear (append) mode"
49         depends on BLK_DEV_MD
50         ---help---
51           If you say Y here, then your multiple devices driver will be able to
52           use the so-called linear mode, i.e. it will combine the hard disk
53           partitions by simply appending one to the other.
55           To compile this as a module, choose M here: the module
56           will be called linear.
58           If unsure, say Y.
60 config MD_RAID0
61         tristate "RAID-0 (striping) mode"
62         depends on BLK_DEV_MD
63         ---help---
64           If you say Y here, then your multiple devices driver will be able to
65           use the so-called raid0 mode, i.e. it will combine the hard disk
66           partitions into one logical device in such a fashion as to fill them
67           up evenly, one chunk here and one chunk there. This will increase
68           the throughput rate if the partitions reside on distinct disks.
70           Information about Software RAID on Linux is contained in the
71           Software-RAID mini-HOWTO, available from
72           <http://www.tldp.org/docs.html#howto>. There you will also
73           learn where to get the supporting user space utilities raidtools.
75           To compile this as a module, choose M here: the module
76           will be called raid0.
78           If unsure, say Y.
80 config MD_RAID1
81         tristate "RAID-1 (mirroring) mode"
82         depends on BLK_DEV_MD
83         ---help---
84           A RAID-1 set consists of several disk drives which are exact copies
85           of each other.  In the event of a mirror failure, the RAID driver
86           will continue to use the operational mirrors in the set, providing
87           an error free MD (multiple device) to the higher levels of the
88           kernel.  In a set with N drives, the available space is the capacity
89           of a single drive, and the set protects against a failure of (N - 1)
90           drives.
92           Information about Software RAID on Linux is contained in the
93           Software-RAID mini-HOWTO, available from
94           <http://www.tldp.org/docs.html#howto>.  There you will also
95           learn where to get the supporting user space utilities raidtools.
97           If you want to use such a RAID-1 set, say Y.  To compile this code
98           as a module, choose M here: the module will be called raid1.
100           If unsure, say Y.
102 config MD_RAID10
103         tristate "RAID-10 (mirrored striping) mode"
104         depends on BLK_DEV_MD
105         ---help---
106           RAID-10 provides a combination of striping (RAID-0) and
107           mirroring (RAID-1) with easier configuration and more flexible
108           layout.
109           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110           be the same size (or at least, only as much as the smallest device
111           will be used).
112           RAID-10 provides a variety of layouts that provide different levels
113           of redundancy and performance.
115           RAID-10 requires mdadm-1.7.0 or later, available at:
117           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
119           If unsure, say Y.
121 config MD_RAID456
122         tristate "RAID-4/RAID-5/RAID-6 mode"
123         depends on BLK_DEV_MD
124         select RAID6_PQ
125         select ASYNC_MEMCPY
126         select ASYNC_XOR
127         select ASYNC_PQ
128         select ASYNC_RAID6_RECOV
129         ---help---
130           A RAID-5 set of N drives with a capacity of C MB per drive provides
131           the capacity of C * (N - 1) MB, and protects against a failure
132           of a single drive. For a given sector (row) number, (N - 1) drives
133           contain data sectors, and one drive contains the parity protection.
134           For a RAID-4 set, the parity blocks are present on a single drive,
135           while a RAID-5 set distributes the parity across the drives in one
136           of the available parity distribution methods.
138           A RAID-6 set of N drives with a capacity of C MB per drive
139           provides the capacity of C * (N - 2) MB, and protects
140           against a failure of any two drives. For a given sector
141           (row) number, (N - 2) drives contain data sectors, and two
142           drives contains two independent redundancy syndromes.  Like
143           RAID-5, RAID-6 distributes the syndromes across the drives
144           in one of the available parity distribution methods.
146           Information about Software RAID on Linux is contained in the
147           Software-RAID mini-HOWTO, available from
148           <http://www.tldp.org/docs.html#howto>. There you will also
149           learn where to get the supporting user space utilities raidtools.
151           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
152           compile this code as a module, choose M here: the module
153           will be called raid456.
155           If unsure, say Y.
157 config MULTICORE_RAID456
158         bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
159         depends on MD_RAID456
160         depends on SMP
161         depends on EXPERIMENTAL
162         ---help---
163           Enable the raid456 module to dispatch per-stripe raid operations to a
164           thread pool.
166           If unsure, say N.
168 config MD_MULTIPATH
169         tristate "Multipath I/O support"
170         depends on BLK_DEV_MD
171         help
172           MD_MULTIPATH provides a simple multi-path personality for use
173           the MD framework.  It is not under active development.  New
174           projects should consider using DM_MULTIPATH which has more
175           features and more testing.
177           If unsure, say N.
179 config MD_FAULTY
180         tristate "Faulty test module for MD"
181         depends on BLK_DEV_MD
182         help
183           The "faulty" module allows for a block device that occasionally returns
184           read or write errors.  It is useful for testing.
186           In unsure, say N.
188 config BLK_DEV_DM
189         tristate "Device mapper support"
190         ---help---
191           Device-mapper is a low level volume manager.  It works by allowing
192           people to specify mappings for ranges of logical sectors.  Various
193           mapping types are available, in addition people may write their own
194           modules containing custom mappings if they wish.
196           Higher level volume managers such as LVM2 use this driver.
198           To compile this as a module, choose M here: the module will be
199           called dm-mod.
201           If unsure, say N.
203 config DM_DEBUG
204         boolean "Device mapper debugging support"
205         depends on BLK_DEV_DM
206         ---help---
207           Enable this for messages that may help debug device-mapper problems.
209           If unsure, say N.
211 config DM_CRYPT
212         tristate "Crypt target support"
213         depends on BLK_DEV_DM
214         select CRYPTO
215         select CRYPTO_CBC
216         ---help---
217           This device-mapper target allows you to create a device that
218           transparently encrypts the data on it. You'll need to activate
219           the ciphers you're going to use in the cryptoapi configuration.
221           Information on how to use dm-crypt can be found on
223           <http://www.saout.de/misc/dm-crypt/>
225           To compile this code as a module, choose M here: the module will
226           be called dm-crypt.
228           If unsure, say N.
230 config DM_SNAPSHOT
231        tristate "Snapshot target"
232        depends on BLK_DEV_DM
233        ---help---
234          Allow volume managers to take writable snapshots of a device.
236 config DM_MIRROR
237        tristate "Mirror target"
238        depends on BLK_DEV_DM
239        ---help---
240          Allow volume managers to mirror logical volumes, also
241          needed for live data migration tools such as 'pvmove'.
243 config DM_RAID
244        tristate "RAID 1/4/5/6 target (EXPERIMENTAL)"
245        depends on BLK_DEV_DM && EXPERIMENTAL
246        select MD_RAID1
247        select MD_RAID456
248        select BLK_DEV_MD
249        ---help---
250          A dm target that supports RAID1, RAID4, RAID5 and RAID6 mappings
252          A RAID-5 set of N drives with a capacity of C MB per drive provides
253          the capacity of C * (N - 1) MB, and protects against a failure
254          of a single drive. For a given sector (row) number, (N - 1) drives
255          contain data sectors, and one drive contains the parity protection.
256          For a RAID-4 set, the parity blocks are present on a single drive,
257          while a RAID-5 set distributes the parity across the drives in one
258          of the available parity distribution methods.
260          A RAID-6 set of N drives with a capacity of C MB per drive
261          provides the capacity of C * (N - 2) MB, and protects
262          against a failure of any two drives. For a given sector
263          (row) number, (N - 2) drives contain data sectors, and two
264          drives contains two independent redundancy syndromes.  Like
265          RAID-5, RAID-6 distributes the syndromes across the drives
266          in one of the available parity distribution methods.
268 config DM_LOG_USERSPACE
269         tristate "Mirror userspace logging (EXPERIMENTAL)"
270         depends on DM_MIRROR && EXPERIMENTAL && NET
271         select CONNECTOR
272         ---help---
273           The userspace logging module provides a mechanism for
274           relaying the dm-dirty-log API to userspace.  Log designs
275           which are more suited to userspace implementation (e.g.
276           shared storage logs) or experimental logs can be implemented
277           by leveraging this framework.
279 config DM_ZERO
280         tristate "Zero target"
281         depends on BLK_DEV_DM
282         ---help---
283           A target that discards writes, and returns all zeroes for
284           reads.  Useful in some recovery situations.
286 config DM_MULTIPATH
287         tristate "Multipath target"
288         depends on BLK_DEV_DM
289         # nasty syntax but means make DM_MULTIPATH independent
290         # of SCSI_DH if the latter isn't defined but if
291         # it is, DM_MULTIPATH must depend on it.  We get a build
292         # error if SCSI_DH=m and DM_MULTIPATH=y
293         depends on SCSI_DH || !SCSI_DH
294         ---help---
295           Allow volume managers to support multipath hardware.
297 config DM_MULTIPATH_QL
298         tristate "I/O Path Selector based on the number of in-flight I/Os"
299         depends on DM_MULTIPATH
300         ---help---
301           This path selector is a dynamic load balancer which selects
302           the path with the least number of in-flight I/Os.
304           If unsure, say N.
306 config DM_MULTIPATH_ST
307         tristate "I/O Path Selector based on the service time"
308         depends on DM_MULTIPATH
309         ---help---
310           This path selector is a dynamic load balancer which selects
311           the path expected to complete the incoming I/O in the shortest
312           time.
314           If unsure, say N.
316 config DM_DELAY
317         tristate "I/O delaying target (EXPERIMENTAL)"
318         depends on BLK_DEV_DM && EXPERIMENTAL
319         ---help---
320         A target that delays reads and/or writes and can send
321         them to different devices.  Useful for testing.
323         If unsure, say N.
325 config DM_UEVENT
326         bool "DM uevents (EXPERIMENTAL)"
327         depends on BLK_DEV_DM && EXPERIMENTAL
328         ---help---
329         Generate udev events for DM events.
331 config DM_FLAKEY
332        tristate "Flakey target (EXPERIMENTAL)"
333        depends on BLK_DEV_DM && EXPERIMENTAL
334        ---help---
335          A target that intermittently fails I/O for debugging purposes.
337 endif # MD