8322 nl: misleading-indentation
[unleashed/tickless.git] / usr / src / cmd / fm / dicts / SUN4.po
blobc804c36e791606cf249a3e3688f8bbe084c36f4e
2 # Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
3 # Use is subject to license terms.
5 # CDDL HEADER START
7 # The contents of this file are subject to the terms of the
8 # Common Development and Distribution License (the "License").
9 # You may not use this file except in compliance with the License.
11 # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12 # or http://www.opensolaris.org/os/licensing.
13 # See the License for the specific language governing permissions
14 # and limitations under the License.
16 # When distributing Covered Code, include this CDDL HEADER in each
17 # file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18 # If applicable, add the following below this CDDL HEADER, with the
19 # fields enclosed by brackets "[]" replaced with your own identifying
20 # information: Portions Copyright [yyyy] [name of copyright owner]
22 # CDDL HEADER END
24 #ident  "%Z%%M% %I%     %E% SMI"
26 # DO NOT EDIT -- this file is generated by the Event Registry.
29 # code: SUN4-8000-0Y
30 # keys: fault.io.fire.asic
32 msgid "SUN4-8000-0Y.type"
33 msgstr "Fault"
34 msgid "SUN4-8000-0Y.severity"
35 msgstr "Critical"
36 msgid "SUN4-8000-0Y.description"
37 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
38 msgid "SUN4-8000-0Y.response"
39 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
40 msgid "SUN4-8000-0Y.impact"
41 msgstr "Loss of services provided by the device instances associated with this fault"
42 msgid "SUN4-8000-0Y.action"
43 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
45 # code: SUN4-8000-13
46 # keys: fault.io.ebus
48 msgid "SUN4-8000-13.type"
49 msgstr "Fault"
50 msgid "SUN4-8000-13.severity"
51 msgstr "Critical"
52 msgid "SUN4-8000-13.description"
53 msgstr "A problem was detected in the Ebus.  Refer to %s for more information."
54 msgid "SUN4-8000-13.response"
55 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
56 msgid "SUN4-8000-13.impact"
57 msgstr "Loss of services provided by the device instances associated with this fault"
58 msgid "SUN4-8000-13.action"
59 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
61 # code: SUN4-8000-2H
62 # keys: fault.io.datapath
64 msgid "SUN4-8000-2H.type"
65 msgstr "Fault"
66 msgid "SUN4-8000-2H.severity"
67 msgstr "Critical"
68 msgid "SUN4-8000-2H.description"
69 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
70 msgid "SUN4-8000-2H.response"
71 msgstr "None"
72 msgid "SUN4-8000-2H.impact"
73 msgstr "None"
74 msgid "SUN4-8000-2H.action"
75 msgstr "None"
77 # code: SUN4-8000-3D
78 # keys: fault.io.hbus
80 msgid "SUN4-8000-3D.type"
81 msgstr "Fault"
82 msgid "SUN4-8000-3D.severity"
83 msgstr "Critical"
84 msgid "SUN4-8000-3D.description"
85 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
86 msgid "SUN4-8000-3D.response"
87 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
88 msgid "SUN4-8000-3D.impact"
89 msgstr "Loss of services provided by the device instances associated with this fault"
90 msgid "SUN4-8000-3D.action"
91 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
93 # code: SUN4-8000-4P
94 # keys: fault.io.fire.pciex.device
96 msgid "SUN4-8000-4P.type"
97 msgstr "Fault"
98 msgid "SUN4-8000-4P.severity"
99 msgstr "Critical"
100 msgid "SUN4-8000-4P.description"
101 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
102 msgid "SUN4-8000-4P.response"
103 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
104 msgid "SUN4-8000-4P.impact"
105 msgstr "Loss of services provided by the device instances associated with this fault"
106 msgid "SUN4-8000-4P.action"
107 msgstr "\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
109 # code: SUN4-8000-5A
110 # keys: defect.io.fire.pciex.driver
112 msgid "SUN4-8000-5A.type"
113 msgstr "Defect"
114 msgid "SUN4-8000-5A.severity"
115 msgstr "Critical"
116 msgid "SUN4-8000-5A.description"
117 msgstr "A problem was detected in the PCI-Express subsystem software.\n  Refer to %s for more information."
118 msgid "SUN4-8000-5A.response"
119 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
120 msgid "SUN4-8000-5A.impact"
121 msgstr "Loss of services provided by the device instances associated with\nthis problem"
122 msgid "SUN4-8000-5A.action"
123 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
125 # code: SUN4-8000-6S
126 # keys: fault.io.datapath fault.io.fire.asic
128 msgid "SUN4-8000-6S.type"
129 msgstr "Fault"
130 msgid "SUN4-8000-6S.severity"
131 msgstr "Critical"
132 msgid "SUN4-8000-6S.description"
133 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
134 msgid "SUN4-8000-6S.response"
135 msgstr "None"
136 msgid "SUN4-8000-6S.impact"
137 msgstr "None"
138 msgid "SUN4-8000-6S.action"
139 msgstr "None"
141 # code: SUN4-8000-75
142 # keys: fault.io.fire.asic fault.io.fire.pciex.device
144 msgid "SUN4-8000-75.type"
145 msgstr "Fault"
146 msgid "SUN4-8000-75.severity"
147 msgstr "Critical"
148 msgid "SUN4-8000-75.description"
149 msgstr "A problem was detected in the PCI-Express subsystem.\n  Refer to %s for more information."
150 msgid "SUN4-8000-75.response"
151 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
152 msgid "SUN4-8000-75.impact"
153 msgstr "Loss of services provided by the device instances associated with this fault"
154 msgid "SUN4-8000-75.action"
155 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
157 # code: SUN4-8000-8E
158 # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
160 msgid "SUN4-8000-8E.type"
161 msgstr "Defect"
162 msgid "SUN4-8000-8E.severity"
163 msgstr "Critical"
164 msgid "SUN4-8000-8E.description"
165 msgstr "A problem was detected in the PCI-Express subsystem software.  Refer to %s for more information."
166 msgid "SUN4-8000-8E.response"
167 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
168 msgid "SUN4-8000-8E.impact"
169 msgstr "Loss of services provided by the device instances associated with this problem"
170 msgid "SUN4-8000-8E.action"
171 msgstr "Ensure latest driver and patch are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
173 # code: SUN4-8000-9J
174 # keys: fault.io.fire.pci.device fault.io.fire.pciex.device
176 msgid "SUN4-8000-9J.type"
177 msgstr "Fault"
178 msgid "SUN4-8000-9J.severity"
179 msgstr "Critical"
180 msgid "SUN4-8000-9J.description"
181 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
182 msgid "SUN4-8000-9J.response"
183 msgstr "None"
184 msgid "SUN4-8000-9J.impact"
185 msgstr "None"
186 msgid "SUN4-8000-9J.action"
187 msgstr "None"
189 # code: SUN4-8000-A2
190 # keys: fault.io.fire.pci.device
192 msgid "SUN4-8000-A2.type"
193 msgstr "Fault"
194 msgid "SUN4-8000-A2.severity"
195 msgstr "Critical"
196 msgid "SUN4-8000-A2.description"
197 msgstr "A problem was detected in the PCI subsystem.\n  Refer to %s for more information."
198 msgid "SUN4-8000-A2.response"
199 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
200 msgid "SUN4-8000-A2.impact"
201 msgstr "Loss of services provided by the device instances associated with this fault"
202 msgid "SUN4-8000-A2.action"
203 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
205 # code: SUN4-8000-CX
206 # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
208 msgid "SUN4-8000-CX.type"
209 msgstr "Fault"
210 msgid "SUN4-8000-CX.severity"
211 msgstr "Critical"
212 msgid "SUN4-8000-CX.description"
213 msgstr "This is an unexpected diagnosis. Please contact Sun support for details.  Refer to %s for more information."
214 msgid "SUN4-8000-CX.response"
215 msgstr "None"
216 msgid "SUN4-8000-CX.impact"
217 msgstr "None"
218 msgid "SUN4-8000-CX.action"
219 msgstr "None"
221 # code: SUN4-8000-D4
222 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
224 msgid "SUN4-8000-D4.type"
225 msgstr "Fault"
226 msgid "SUN4-8000-D4.severity"
227 msgstr "Critical"
228 msgid "SUN4-8000-D4.description"
229 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
230 msgid "SUN4-8000-D4.response"
231 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
232 msgid "SUN4-8000-D4.impact"
233 msgstr "Loss of services provided by the device instances associated with this fault"
234 msgid "SUN4-8000-D4.action"
235 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
237 # code: SUN4-8000-ER
238 # keys: fault.io.fire.asic fault.io.fire.pci.device
240 msgid "SUN4-8000-ER.type"
241 msgstr "Fault"
242 msgid "SUN4-8000-ER.severity"
243 msgstr "Critical"
244 msgid "SUN4-8000-ER.description"
245 msgstr "A problem has been detected in the PCI/PCI-Express subsystem.  Refer to %s for more information."
246 msgid "SUN4-8000-ER.response"
247 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
248 msgid "SUN4-8000-ER.impact"
249 msgstr "Loss of services provided by the device instances associated with this fault"
250 msgid "SUN4-8000-ER.action"
251 msgstr "Schedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.  If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
253 # code: SUN4-8000-FC
254 # keys: fault.io.fire.hbus
256 msgid "SUN4-8000-FC.type"
257 msgstr "Fault"
258 msgid "SUN4-8000-FC.severity"
259 msgstr "Major"
260 msgid "SUN4-8000-FC.description"
261 msgstr "A problem was detected in a system core bus.\n  Refer to %s for more information."
262 msgid "SUN4-8000-FC.response"
263 msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services."
264 msgid "SUN4-8000-FC.impact"
265 msgstr "Loss of services provided by the device instances associated with this fault"
266 msgid "SUN4-8000-FC.action"
267 msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
269 # code: SUN4-8000-GQ
270 # keys: fault.io.fire.datapath fault.io.fire.hbus
272 msgid "SUN4-8000-GQ.type"
273 msgstr "Fault"
274 msgid "SUN4-8000-GQ.severity"
275 msgstr "Critical"
276 msgid "SUN4-8000-GQ.description"
277 msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n  Refer to %s for more information."
278 msgid "SUN4-8000-GQ.response"
279 msgstr "One or more device instances may be disabled\n"
280 msgid "SUN4-8000-GQ.impact"
281 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
282 msgid "SUN4-8000-GQ.action"
283 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
285 # code: SUN4-8000-HD
286 # keys: fault.io.fire.hb.sw-config
288 msgid "SUN4-8000-HD.type"
289 msgstr "Fault"
290 msgid "SUN4-8000-HD.severity"
291 msgstr "Critical"
292 msgid "SUN4-8000-HD.description"
293 msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
294 msgid "SUN4-8000-HD.response"
295 msgstr "One or more device instances may be disabled\n"
296 msgid "SUN4-8000-HD.impact"
297 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
298 msgid "SUN4-8000-HD.action"
299 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
301 # code: SUN4-8000-JH
302 # keys: fault.io.fire.dmc.sw-algorithm
304 msgid "SUN4-8000-JH.type"
305 msgstr "Fault"
306 msgid "SUN4-8000-JH.severity"
307 msgstr "Critical"
308 msgid "SUN4-8000-JH.description"
309 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
310 msgid "SUN4-8000-JH.response"
311 msgstr "One or more device instances may be disabled\n"
312 msgid "SUN4-8000-JH.impact"
313 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
314 msgid "SUN4-8000-JH.action"
315 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
317 # code: SUN4-8000-K3
318 # keys: fault.io.fire.dmc.sw-state
320 msgid "SUN4-8000-K3.type"
321 msgstr "Fault"
322 msgid "SUN4-8000-K3.severity"
323 msgstr "Critical"
324 msgid "SUN4-8000-K3.description"
325 msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n  Refer to %s for more information."
326 msgid "SUN4-8000-K3.response"
327 msgstr "One or more device instances may be disabled\n"
328 msgid "SUN4-8000-K3.impact"
329 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
330 msgid "SUN4-8000-K3.action"
331 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
333 # code: SUN4-8000-LY
334 # keys: fault.io.fire.pec.sw-algorithm
336 msgid "SUN4-8000-LY.type"
337 msgstr "Fault"
338 msgid "SUN4-8000-LY.severity"
339 msgstr "Critical"
340 msgid "SUN4-8000-LY.description"
341 msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n  Refer to %s for more information."
342 msgid "SUN4-8000-LY.response"
343 msgstr "One or more device instances may be disabled\n"
344 msgid "SUN4-8000-LY.impact"
345 msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
346 msgid "SUN4-8000-LY.action"
347 msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"